QUICK REFERENCE GUIDE
Page 1: ...QUICK REFERENCE GUIDE...
Page 2: ...everal kinds of data runs may need to be performed to achieve desired information or the same data run may be performed repeatedly over time to monitor one process Either way each data run must be set...
Page 3: ...ler Power Pack battery is fully charged When a M O L E Thermal Profiler is selected the software status bar displays the current battery voltage 4 On the File menu click New The Start dialog box appea...
Page 4: ...s sion through the wizard Current Completed Remaining 5 On the Start dialog box click the Fresh Start command button and the workflow wizard appears 6 Select the desired instrument from the list box t...
Page 5: ...n to create a new machine 9 Set the machine recipe settings such as Conveyor Speed Zone Temperatures and Temperature units The software includes features to save and load machine recipe setting files...
Page 6: ...nd the sensor leads and insert the connectors into the M O L E Thermal Profiler Make sure to connect them to the same channel s that were configured in the wizard workflow 14 Locate the thermocouple s...
Page 7: ...ofile Type Ramp Soak Spike or Ramp to Spike If your Paste does not appear in the database list click the New command button to create a new one 16 Click the Next command button When the user selects a...
Page 8: ...is optimal for solar metallization processes 17 Set Recording Parameters such as the instrument name recording interval start parameters and stop parameters This step is where the user can also turn...
Page 9: ...ting good data they are highlighted and a RED sign is displayed 19 Verify the instrument status This dialog box displays the health of the M O L E Thermal Profiler such as battery charge internal temp...
Page 10: ...The thermal barrier supplied with the system is specifically designed to protect the M O L E through typical solar metalliza tion processes 2 After the oven stabilizes 1 Place the M O L E Thermal Prof...
Page 11: ...or Points Delay are configured It is highly recommended that protective gloves are used when retrieving the thermal barrier from the oven and when opening the thermal barrier 3 Pass the thermally prot...
Page 12: ...topped by pressing the Record button If a thermocouple sensor is removed before the M O L E Thermal Profiler has stopped recording data the data for that channel will show as OPEN T C 6 Remove the M O...
Page 13: ...to read the data run from the M O L E Thermal Profiler On this step of the wizard the user has the ability to remove a selected data run from the V M O L E Thermal Profiler by either selecting the De...
Page 14: ...13 OPERATION FRESH START 2 When the data run has been down loaded the software will prompt the user to save the data run file XMG 3 When finished click the Save command button...
Page 15: ...ange a zone temperature values or the conveyor speed and predict the outcome of that change on the data run profile 5 Click the Predict command button to enter Prediction mode or Done to complete the...
Page 16: ...0 2010 ECD All Rights Reserved Foreign and US Products of ECD are covered by US Patents and Patents Pending The trapezoidal ECD logo and M O L E Multi Channel Occurrent Logger Evaluator are registered...