background image

 

 

LumInsight IoT Gateway and Base Station – Ethernet 

 

 

Rev. B (July 2018) 

Setup Guide (Network Configuration)

 

1

 

078-1074-01B

  

 

LumInsight IoT Gateway and 

Base Station – Ethernet 

Setup Guide (Network Configuration) 

Models 100150-201 and 100150-281

 

Introduction 

LumInsight  IoT  Gateway  and  Base  Station  are  a  set  of 
Echelon’s  Edge  Servers  for  use  with  the  LumInsight  2 
Central  Management  System  (CMS).  The  Gateway  or 
Base  Station  manages  a  network  of  lighting  controllers 
and  other  devices  over  a  LumInsight  RF  network.  The 
data  from  the  Gateway  or  Base  Station  is  back-hauled 
over  a  LAN/WAN  or  Cellular  connection.  This  guide  is 
used to set up the LAN/WAN connection.   

Setup Guide Overview   

This  document  provides  the  instructions  needed  for 
network configuration for access by a LumInsight CMS. 
The  network  settings  configuration  is  end-user  specific 
and  requires  the  appropriate  IP  address,  Netmask,  and 
Default IP Gateway to be obtained from the IT staff at the 
location where the Ethernet Gateway will be installed. A 

LumInsight  IoT  Gateway  Network  Information  Request 
(NIR) Form

 must be completed by the customer’s IT staff. 

Information about the NIR form is provided at the end of 
this guide. 

Parts and Accessories   

The  following  parts  and  accessories  are  required  for  the 
LumInsight  IoT  Gateway  and  Base  Station  network 
configuration: 

  Desktop or laptop (recommended) computer with 

an Ethernet port 

 

  CAT 5 patch cable 

 

  LumInsight IoT Gateway (Ethernet model number 

100150-201)  or  Base  Station  (Ethernet  model 
number 100150-281)

 

Network Settings Configuration 

CAUTION: Make sure that the computer being used is 
not connected to any other network and is configured 
to receive an IP address from a DHCP server. 

To  configure  the  network  settings  for  a  LumInsight  IoT 
Gateway and Base Station, perform the following steps: 

1.  Open  the  IP66  enclosure  and  locate  the  CloudGate 

device inside (refer to the figure below).

 

 

CloudGate Device

 

2.  Connect one end of the Ethernet cable to the CloudGate.

 

3.  Connect  the  other  end  of  the  Ethernet  cable  to  a 

computer (refer to the figure below). 

 

 

Ethernet Cable Connection

 

4.  Connect the power adapter to the CloudGate and apply 

power. 

 

As  the  CloudGate  boots,  the  system  state  LED  turns 
orange; 

wait until it turns green

.  

When  the  boot  process  completes,  the  computer  will 
have  an  active  network  connection  with  a  valid  IP 
address.  

5.  Open  a  browser  window  and  go  to  the  address 

http://192.168.1.1

.

 

A CloudGate Login page should appear as shown in the 
screen below, confirming a good Ethernet connection to 
the CloudGate.  

 

CloudGate Login Page

 

6.  Enter the following credentials to login to the CloudGate 

web interface:

 

Username: admin  
Password: @Echelon123! 

7.  On the CloudGate Home page, click on the 

Interfaces

 

menu item and then select the 

Main Ethernet

 option as 

shown 

in 

the 

screen 

that 

follows.  

 

 
 


 

Reviews: