background image

Echoflex Installation Guide

Elaho Dual Tech Switch-mount Occupancy

Corporate Headquarters

n

 Middleton, WI, USA 

|

 +1 608 831 4116

© 2023 Echoflex Solutions, Inc.

|

 Trademark and patent info:

echoflexsolutions.com/ip

Web

echoflexsolutions.com

|

Email

info@echoflexsolutions.com

|

Support

service@echoflexsolutions.com

Third-party license agreement info: 

etcconnect.com/licenses

|

 Product information and specifications subject to

change. Echoflex intends this document to be provided in its entirety.

8186M2187

 Rev C Released 2023-06

Overview

The Elaho Dual Tech Switch-mount Occupancy Sensor is a switch station
with a built-in sensor that uses passive infrared (PIR) and acoustic
detection to provide reliable occupancy and vacancy sensing for lighting
control.

The Dual Tech Switch-mount
Occupancy Sensor is available in

1–button and 2–button models, and

is available with white, black, cream,
or gray wall plate.

Each button is back lit by both blue and amber LEDs to show changes in
status. The sensor provides a 180 degree field of view with up to 13.7 m
(45 ft) radius for large motion detection.

This document guides you through the installation and local
configuration of the Dual Tech Switch-mount Occupancy Sensor.

Custom Configuration

For more information about the custom configuration options available
using ElahoAccess, reference the ElahoAccess Mobile App integrated help
system.

Note:

Settings made using ElahoAccess are applied only when

the function selection switch is set to Custom (middle position).
Reference

Function Switch on page 11

.

Summary of Contents for Elaho

Page 1: ...tection to provide reliable occupancy and vacancy sensing for lighting control The Dual Tech Switch mount Occupancy Sensor is available in 1 button and 2 button models and is available with white blac...

Page 2: ...maximum of 90 non condensing humidity Installation Echoflex recommends paying special attention to the installation environment When operating in PIR only modes the sensor must have an unobstructed vi...

Page 3: ...box for connection and to allow slack for future service needs Note Echoflex requires that all stations and devices be grounded for ESD protection Pull an additional 2 5 mm2 14 AWG wire for grounding...

Page 4: ...incoming ground wire b Use one WAGO connector provided in the termination kit to connect the station ESD ground pigtail and the incoming ground For stations using grounded metal conduit connect the g...

Page 5: ...Space DIP Switch Settings DIP switches provide for designation of Off functionality the ability to disable amber button LEDs and the ability to restore the sensor to its factory defaults Switch Use 1...

Page 6: ...the sensor When set to Off default both PIR and acoustic detection technologies are used by the sensor 7 Unused 8 Restore to Defaults at boot When set to On then cycling power to the switch mount sta...

Page 7: ...station electronics Each corner of the bezel is provided with a notch to assist with bezel removal Use a finger nail to lift a corner free then gently remove the bezel from the station rium n Entry i...

Page 8: ...ly installed 2 Use spacers as needed to provide a flush mounted station a Fold the spacer in a zig zag fashion and press the stack together to achieve the thickness needed to fill the gap between the...

Page 9: ...gnment secure the screws then retry wall plate installation Power Up and Test Power Up All EchoConnect terminations in the system must be made before applying power to the system and sensor When the s...

Page 10: ...r control by the Elaho control system b You will need direct access to the sensor in order to place it into Walk Test mode 2 Remove the sensor wall plate to gain access to the Walk Test button 3 Press...

Page 11: ...vacancy detection Reference Program Preset Start Basic Mode Preset or Zone on page 13 Function Switch The Function switch determines how the controls of the sensor function It has behavior settings o...

Page 12: ...atures either with or without ElahoAccess although the presence of ElahoAccess in the control system allows for an expanded feature set With ElahoAccess ElahoAccess provides complete customization of...

Page 13: ...h vacancy detection 1 Set the station Function switch to Preset the highest switch position 2 Press and hold the Walk Test Program Mode button for three seconds to enter Program Mode The Mode LED illu...

Page 14: ...ashes five times 3 Push button 1 to increase the starting zone number by one any new count always begins at 1 The station updates the LED indication flashing the LED to reflect the new zone number For...

Page 15: ...set to Off Reference DIP Switch Settings on page 5 The Function switch is set to Custom and Zone 2 is the default With the Function switch set to Preset Preset 1 is the default With the Function switc...

Page 16: ...le the preset using a 1 2 second fade time Custom While the 1 button Switch mount Sensor supports the following default button actions in Custom mode complete customization is available when using Ela...

Page 17: ...he Function switch is set to Custom and Zone 2 is the default With the Function switch set to Preset Preset 1 is the default With the Function switch set to Zone Zone 1 is the default Preset In Preset...

Page 18: ...activates the zone that is configured to button 1 at full and the vacancy detection event deactivates the Zone set to 0 The 2 Button sensor supports the following button actions Double tap the button...

Page 19: ...ancy event activates the zone that is configured to button 1 at full and the vacancy detection event deactivates the Zone set to 0 Double tap the button to toggle the preset using a 1 2 second fade ti...

Page 20: ...nce The Dual Tech Switch mount Occupancy Sensor is for use with Echoflex dimming and relay products For current and complete compliance information view the product datasheet at echoflexsolutions com...

Reviews: