Firmware V 1.04 

 
 
 

 
 
 
 

 

 

 
 
 
 

 
 
 
CAN bus-PC Adapter
:  

Order number: LICANBUSAD 

Accessory: Y-cable for connecting the PC to the CAN bus 
(e.g. for service purposes): 

Order number: LICANYKAB

Operating instructions 

Summary of Contents for LICANBUSAD

Page 1: ...ERT CHAIRPERSOON OF THE SUPERVISORY BOARD HUBERTUS G KROSSA REGISTERED DISTRICT COURT WIESBADEN HRB 12636 eckelmann de CAN bus PC Adapter Firmware V 1 04 CAN bus PC Adapter Order number LICANBUSAD Accessory Y cable for connecting the PC to the CAN bus e g for service purposes Order number LICANYKAB Operating instructions ...

Page 2: ...e ECKELMANN AG company In particular neither the contract partners of ECKELMANN AG nor other users have the right to distribute or market the IT programs program parts or modified or edited versions without express written permission To some extent names of products goods or designations are protected for the respective manufacturer registered trademarks etc in any case no guarantee is assumed for...

Page 3: ... Technical safety information 4 2 Function of the CAN Bus Adapter 5 3 Installation and Commissioning of the CAN Bus to PC Adapter 5 3 1 Installation of the CAN bus connection 6 3 2 Commissioning 8 4 Operating states 10 5 Technical data 11 5 1 Electrical data CAN bus to PC adapter 11 5 2 Electrical date power pack 11 5 3 Mechanical data CAN bus to PC adapter 12 ...

Page 4: ...ly be conducted when the electricity supply to the assembly has been cut off 3 The faultless and safe operation of the product presupposes proper transport appropriate storage positioning and assembly as well as careful operation and maintenance 4 Voltage must only be supplied by VDE tested and CE certified power packs 5 Ensure that the voltage supply and the data cable are correctly connected 6 I...

Page 5: ...bles LDSWin connection to CI 3000 CI 3100 CI 300 store computer when COM port is occupied by modem Integration in the E LDS system The CAN bus connection is based on the CiA standard The CAN bus PC adapter b must be provided with power by an external power pack e provided The CAN bus to PC adapter is connected to the PC serial port COM port by means of a special adapter cable a provided Connection...

Page 6: ...il in the chapter Introduction The following 3 steps are required 1 Connect the CAN bus cable to the Sub Min D plug see table 3 1 1 and picture 3 1 1 CAN bus Wire colour 9 pole Sub Min D COMBICON plug Comments SHLD SHLD 1 SHLD is ONLY to be connected to the pull relief on the 9 pole Sub Min D plug housing see picture 3 1 1 CAN GND Green Pin 3 2 CAN Low Brown Pin 2 3 CAN High White Pin 7 4 If the a...

Page 7: ...e Sub Min D plug The additional use of the CAN SHLD in the Sub Min D plug can cause problems as the E LDS system s CAN bus uses CAN SHLD and CAN GND differently although these signals are connected internally within the adapter Incorrect shielding can lead to electromagnetic noise fields During wiring work it is essential that the conductors be connected by a professional and correctly shielded If...

Page 8: ...the CAN bus to PC adapter consists of the following 8 steps 1 Turn off the PC 2 Connect the RS232 plug a of the adapter b with the PC s serial interface COM port 3 Attach the Sub Min D plug c to the adapter b and screw into place 4 Connect the COMBICON plug d with the CAN bus and plug into E LDS components See chapter 3 1 Installation CAN Bus Connection 5 Connect the power pack e to the adapter b ...

Page 9: ...een select the required COM port and CAN bus adapter see picture 3 2 2 and press Accept Picture 3 2 2 CAN Bus to PC Adapter 8 Communication can now be established with the E LDS components via the LDSWin software For further information see the LDSWin Software documentation If communication is only carried out with individual components without a store computer CI 3000 CI 3100 CI 300 being connect...

Page 10: ...n the CAN bus to PC adapter s LIFE LED is lit green During data transmission i e communication between the CAN bus and the PC s serial interface the LEDs CAN and SERIAL flash green on a cyclical basis If the CAN or SERIAL LEDs are lit red then there is a fault in the interfaces Colour LED 1 LIFE LED 2 SERIAL LED 3 CAN Green flashing Operating Data transfer serial Data transfer CAN bus Red lit Faul...

Page 11: ... PC connection 9 pole Sub Min D plug on connection cable Housing Plastic degree of protection IP30 Indicator 3 x Duo LEDs green red Power supply External 7 32 V DC per jack plug Current consumption typically 500 mA at 8 V DC CE conformity Manufacturer s CE declaration of conformity 5 2 Electrical date power pack Technical data Power pack Input voltage 90 260 V AC Output voltage 12 V DC stabilised ...