background image

USER MANUAL 
MANUAL DE INSTRUCCIONES 
NOTICE D’EMPLOI 
BEDIENUNGSANLEITUNG 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for LPA10000

Page 1: ...USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D EMPLOI BEDIENUNGSANLEITUNG ...

Page 2: ......

Page 3: ...rcuit 06 3 6 Output connections 06 4 OPERATION AND USAGE 06 4 1 Start up 06 4 2 Input attenuators 06 4 3 Indicators 07 5 CLEANING 07 6 DIAGRAMS 23 6 1 Connection diagram 23 6 2 Technical characteristics 24 6 3 Block diagram 25 6 4 Function list 26 6 5 Function diagram 27 All numbers subject to variation due to production tolerances ECLER S A reserves the right to make changes or improvements in ma...

Page 4: ...ls are 2 rack units high and are based on a robust chassis Thanks to their oversize power supply the amplifiers can work comfortably at loads of 4 Ω The LPAs include balanced inputs via XLR3 connectors and a jack and non balanced inputs via RCA connectors Their outputs offer complete versatility thanks to the dual format used connectors of the safety terminal type with a normalized distance and Sp...

Page 5: ...E THE FUSE WITH ANOTHER ONE WITH A HIGHER VALUE The mains cables must not be near the shielded cables carrying the audio signal as this could cause humming 3 3 Input signal connections The input connectors for the balanced signal are of the XLR 3 and JACK type 11 13 The assignment is as follows XLR 3 JACK Hot or direct signal Pin 2 Tip Cold or phase inverted signal Pin 3 Ring Ground Pin 1 Sleeve F...

Page 6: ...connected to the amplifier operating in BRIDGE mode is not lower than 8Ω ATTENTION Terminals 1 and 1 should only be used in case of STEREO or PARALLEL mode and terminals 2 and 2 in BRIDGED mode Any other combination may impair final audio quality The connection cable that joins the amplifiers outputs and the loudspeakers must be of good quality sufficient section and as short as possible This is m...

Page 7: ...cal support service CLIP indicators 3 They light up when the amplified signal present in the amplifier output is just below the level of clipping or saturation This system always provides a true indication regardless of the variations in the mains voltage When operating at high power levels it is normal for the CLIP indicators to light up briefly at the moment of low frequencies because it is the ...

Page 8: ...23 6 DIAGRAMS 6 DIAGRAMAS 6 SCHÉMAS 6 DIAGRAMME 6 1 Connection diagram 6 1 Diagrama de conexión 6 1 Schéma de connexion 6 1 Anschlußdiagramm ...

Page 9: ...filter 3dB CH1 LOW CH2 HIGH 150Hz 18dB oct THD Noise 1kHz Full Pwr 0 1 0 05 0 1 S N N 20Hz 20kHz 1W 4Ω 85dB Damping factor 1kHz 8Ω 270 Slew Rate 37V µs 43V µs 30V µs Input connectors XLR3 Jack balanced RCA Gain Impedance 26 32dB 20kΩ Bal 10kΩ Unbal Signal present indicator 40dB Output connectors Speakon Binding Posts Mains 230V 50 60Hz Power consumption pink noise 1 8 power 4ohm 670VA 1040VA 600VA...

Page 10: ...25 6 3 Block diagram 6 3 Diagrama de bloques 6 3 Blocs de diagrammes 6 3 Blockschatbild ...

Page 11: ...avoces 19 Fuse holder 19 Portafusible 20 Mains socket except LPA16000 20 Base de red excepto LPA16000 6 4 Liste de fonctions 6 4 Funktionsliste 1 Atténuateurs d entrée 1 Eingangsregler 2 Indicateur de protection PROTECT 2 Schutzanzeige PROTECT 3 Voyant d écrêtage CLIP 3 Clip Anzeige CLIP 4 Indicateur de présence du signal SIGNAL 4 Signalanzeige SIGNAL 5 Indicateur lumineux PARAL 5 Kontroll LED PAR...

Page 12: ...27 6 5 Function diagram 6 5 Diagrama de funciones 6 5 Schéma de fonctionnement 6 5 Funktionsübersicht ...

Page 13: ...ECLER Laboratorio de electro acústica S A Motors 166 168 08038 Barcelona Spain INTERNET http www ecler com E mail info ecler es 50 0228 01 00 ...

Reviews: