background image

JINECO04 REV I 12/03/15 

 

 

eco 4 

CVSEC04FM 

 

Instructions for: 

Installation/Operating/Maintenance/Servicing 

Approved for use in the United Kingdom and the Republic of Ireland 

 

 

 

Summary of Contents for eco 4

Page 1: ...1 JINECO04 REV I 12 03 15 eco 4 CVSEC04FM Instructions for Installation Operating Maintenance Servicing Approved for use in the United Kingdom and the Republic of Ireland...

Page 2: ...authorised fuels Consumables are deemed to be Glass Seals Gaskets Grate Components Log Retainers Baffles and the surface finish of the appliance The Warranty will only be valid if the appliance is ins...

Page 3: ...nd out if you are in a Smoke Control Area by contacting your Local Authority The Eco Ideal 4 has been fitted with a permanent bypass that prevents closure of the secondary air slider Removal of this w...

Page 4: ...temperatures on or near this appliance Do not place furniture or other items within 1 metre of the front of this appliance See the note on material clearances on page 13 Extractor Fans and or Cooker...

Page 5: ...the presence of children the elderly or the infirm The fireguard should be manufactured in accordance with BS8423 Fireguards for use with solid fuel appliances Do not Over Fire It is possible to fire...

Page 6: ...arbon Monoxide Detector that conforms to the latest issue of BS EN 50292 is placed in the same room as the appliance The installation of such an alarm is not considered as a substitute for regular mai...

Page 7: ...washers Slide the remaining gasket on to the studs of the flue collar or blanking plate and secure in place on the back plate Unless the optional flue damper is being fitted blank off the damper handl...

Page 8: ...chimney is suspected of previously serving an open fire it must be swept again within a month of regular use to clear any soot that may have been dislodged due to the variation in combustion levels a...

Page 9: ...derstood These instructions cover the basic principles to ensure satisfactory installation of the stove although detail may need slight modification to suit particular local site conditions In all cas...

Page 10: ...0 013 0389 Air Supply The room or space containing this appliance should have purpose provided ventilation where necessary in accordance with Building Regulations Due consideration should be given to...

Page 11: ...cannot be reached through the stove with baffle removed a soot door must be fitted in a suitable position Flue Draught If the draught exceeds the recommended maximum a draught stabiliser must be fitt...

Page 12: ...material or tiles at least 12mm thick The hearth should extend at least 150 mm from the sides and rear of the stove and at least 225 mm from the front of the stove All non combustible walls closer tha...

Page 13: ...unt of air can be increased by moving the slider to the right The slider can be unlocked from its position by twisting the control knob anti clockwise Once the slider is in the desired position it can...

Page 14: ...aper dry sticks and or firelighters in the mode chosen either wood or solid mineral fuel Light the fire at the base leaving all air controls open Allow the fuel to reach a steady glow and build the fi...

Page 15: ...down If you want to revive the fire it is recommended that the Primary Air control is open first and then open the secondary air slider REFUELING Add the new fuel to the fire and open both air contro...

Page 16: ...apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas...

Page 17: ...heat up slowly ensuring that no products of combustion enter into the room When the appliance has reached working temperature open the Door and carry out a spillage test using a smoke match around th...

Page 18: ...d with a heat resistant paint and this can be cleaned with a soft brush Do not clean whilst the stove is hot wait until it has cooled down At no point should any water based or other cleaning products...

Page 19: ...e checked for potential obstructions by a competent person before lighting the stove DE ASHING De ashing should be carried out on a regular basis to avoid a buildup of ash and ensure sufficient primar...

Page 20: ...ndows in the room where the appliance is fitted a strange smell when the appliance is lit or water leaking from the appliance Please consult with your installer if you are concerned in any way about t...

Page 21: ...w FSJM05008SS Door Slider CH08003 Glass Gasket ECO06007 Door Handle Assembly ECO06ARRT005 Glass Clip HHR08164 Slider Knob HCE06059 Door Cover HEC07002 Door Glass ECO06008 Rope Sealing Kit SCPHCE09SDSK...

Page 22: ...22 Body Assembly Spares...

Page 23: ...escription Serial Number COMMISSIONING CHECK Complete Sign YES NO Does the chimney flue system meet the appropriate standard Has the chimney flue system been swept and passed the soundness test Has th...

Page 24: ...Signature Signature 5th Service 6th Service Date of Service Date of Service Date of next Service Date of next Service Servicing Company Engineer Servicing Company Engineer Signature Signature 7th Ser...