background image

Desiccant Dehumidifier 

USERS MANUAL

Read This Manual

Inside you will find many helpful hints on how
to use and maintain your dehumidifier properly.
Just a little preventative care on your part can
save you a great deal of time and money over
the life of your dehumidifier. You’ll find many
answers to common problems in the chart of
troubleshooting tips. Review the chart of
Troubleshooting Tips before calling your
service engineers.

DD122FW-MK4

Summary of Contents for DD122 MK4

Page 1: ...ntain your dehumidifier properly Just a little preventative care on your part can save you a great deal of time and money over the life of your dehumidifier You ll find many answers to common problems in the chart of troubleshooting tips Review the chart of Troubleshooting Tips before calling your service engineers ...

Page 2: ...industrial or outdoor use 10 To protect against electrical shocks do not immerse unit plug or cord in water or spray with liquids 11 Never unplug the power cord without press the ON OFF key to off first as this could damage the unit 12 Always unplug the unit when not in use or moving location To disconnect from the power supply grip the plug and pull from the power socket Never pull by the cord 13...

Page 3: ... terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN OR GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened correctly If a 13A...

Page 4: ... of air in your home or office Built in ioniser Electronic louvre Laundry mode includes power saving setting for summer use turbo setting for winter Up to 8 hour timer for added convenience Temperature range for use 1 C 40 C Light portable with carry handle Removable water bucket with handle Operating light Auto restart after power cut Once the power is restored after a power failure the appliance...

Page 5: ...Bucket Handle Plug Operation light illuminates when running Hand grip to pull out the bucket Air inlet Air filter Nano silver Continuous drain hole Water level indicator both sides PRODUCT DESCRIPTION 3 automatic louvre settings ...

Page 6: ...tor Water Full indicator Indicator lights up when the bucket is full of water or incorrectly installed Check indicator Indicator lights up when the unit malfunctions Timer indicators Louvre setting indicators Function indicators Ioniser Key Timer key Louvre settings Control key Laundry Mode key Dry Mode key Power Key ...

Page 7: ...hallway As long as the internal doors are open the excess moisture from all of the rooms in the house will migrate naturally towards the dehumidifier and be processed UNIT SETUP TO OPERATE SAFELY Do not insert small objects into the unit or this will damage it and cause a hazard Do not remove bucket when running or water may leak Keep suitable space as above Ensure bucket is fitted correctly if th...

Page 8: ...is restored after a power failure the appliance will continue to operate at the selected settings prior to the power failure This includes the drying mode swing function and time remaining in timer mode Note After turning the appliance OFF After turning the appliance OFF using the ON OFF button the fan will continue to run for a two minute period This is a normal procedure and helps to cool protec...

Page 9: ...utomatic dehumidification MODE DESCRIPTION The unit automatically keeps room humidity at 55 60 RH To keep the room at a comfortable Relative Humidity RH level To run low fan speed The unit automatically dehumidifies in low fan speed and low noise Super dry mode to prevent dew The unit automatically keeps room humidity at 40 45 RH to prevent dew in the room LAUNDRY MODE Press the LAUNDRY MODE key f...

Page 10: ...selected time period As the time counts down the LED 4 or 2 hours lights will indicate the time remaining 2hrs 4hrs 8hrs continuous LED OFF When no TIMER is set the LED is off the unit will run continuously unless the bucket is already full IONISER Press the IONISER Key to turn on and off the ioniser When the LED is on the unit releases negative ions from the air outlet The automatic louvre swing ...

Page 11: ...ork harder to reduce the room humidity to it s target of 55 60 RH this is the time when it will produce the most water and need emptying most frequently As the room becomes dryer the dehumidifier collects less water and runs at a lower fan speed This is normal When the target relative humidity has been reached the air coming out of the dehumidifier will not be heated and it will only be running in...

Page 12: ...perating as water may leak damage the unit or cause an electric shock 3 To remove the bucket pull it out by gripping the bottom of the bucket and lift carefully 4 Remove the cover of bucket first then pour the water away clean the bucket and restore the cover and the bucket to the correct position Pull bucket out Lift by the handle Remove the cover Pour the water away Restore the cover and the han...

Page 13: ...nit will be affected It is recommended to check and clean the air filter every 2 weeks 1 Turn off the unit and remove the filter from the unit 2 Clean the nano silver filter only with a vacuum cleaner Washing will weaken the germicidal effect of the filter 3 Replace the filter in position Before storing 1 Turn off the unit wait for it to stop and unplug from the power socket 2 Clean and dry the bu...

Page 14: ...n Check and replace the bucket When the performance seems poor Is there any door or window open Is steam being generated in the room Is the room too big Is the filter dirty Clean it Refer to the filter cleaning instructions Is the inlet or the outlet covered When noise occurs Is the unit on a horizontal flat and level surface Move and reset the unit Is the air filter dirty Clean the filter NOTE 1 ...

Page 15: ...NS Model ECO DD122 MK4 Operating Temperature Range 1ºC 40ºC Dehumidification 7 litres day 20ºC 60 RH Water tank capacity 2 Litres Power 620W Voltage 220 240V 50Hz N W 6 Kg G W 7 Kg Product size 47 5H x 29W x 17 5D cm ...

Reviews: