background image

 

                          

 

 

    

 

 

   

                                          

Environmentally activated by

  

 
 
 
 

      

 
 
        

                                                           

 

 
 

     Super ActivO

TM

 

     User Manual 

      

for

 Europe 

      2014 

Summary of Contents for Super ActivO

Page 1: ...Environmentally activated by Super ActivOTM User Manual for Europe 2014 ...

Page 2: ...er settings 8 Activation Deactivation and Total Operating Time 13 Maintenance and Service 14 Troubleshooting 18 Warranty 19 UNPACKING PLEASE SEE OUR UNPACKING VIDEO PROCEDURE AT http ecozone technologies com Products MobileGenerators SuperActivO aspx ΠOpen top flaps of carton Gently place carton on its side Lift unit up slightly and then pull out by rolling on its wheels Place handle on top panel...

Page 3: ...enriched with ozone generated from the air using Ecozone s multi patented technology at a particularly high rate in order to reach homogeneous conditions and a high concentration level within the shortest possible time In the second stage any after treatment residual ozone is decomposed into oxygen so as to leave the treated room well within the regulated levels 2 Declaration of Conformity Model N...

Page 4: ...lation inlet and a ventilation outlet DO NOT BLOCK inlet outlet or place foreign objects in their vicinity which may block air flow Place unit in the CENTER of the room DO NOT disconnect cable cord from mains socket before the operation of the system is completed This unit is supplied with a earthed cable Attempting to bypass the earth or to connect the unit to an un earthed socket is strictly pro...

Page 5: ...ully Automatic Activation Deactivation Cycles Cycle time Minimum 15 minutes Maximum 48 hours With special input code 72 hours ozone generation only Control Digital keyboard Display LCD 16 Digits Safety Circuit breaker 5A Amber Flashing Light Indicator Super ActivO in operation Red Fault Indicator Buzzer Alarm operation has begun operation has ended Differential Pressure Regulator air flow obstruct...

Page 6: ...itions Indoor use only Temperature 5 ºC to 40 ºC Humidity maximum relative humidity 95 ECOZONE Technologies has a policy of continuous product improvement and reserves the right to modify or change this specification at any time without notice ...

Page 7: ...it to the power source socket OZONE IS A POWERFUL OXIDIZER USE THIS EQUIPMENT WITH CARE ONLY IN UNINHABITED AREAS CONTAINING NO PETS PLANTS NATURAL RUBBER OR COMPOUNDS CONTAINING NATURAL RUBBER READ ALL OPERATING INSTRUCTIONS BEFORE USING THIS MACHINE RE OCCUPY TREATED ROOM ONLY AFTER PRESET OPERATING TIME HAS ELAPSED AND THE AMBER FLASHING LIGHT HAS STOPPED FLASHING INDICATING THAT THE MACHINE IS...

Page 8: ...he alternating prompt Ready and Set Room Size Select Room Size by pressing the respective keypad button Note You may choose between the following 4 room sizes Small for room volumes below 30m3 Medium for room volumes between 30m3 and 60m3 Large for room volumes between 60m3 and 120m3 X Large for room volumes from 120m3 to 500m3 O ...

Page 9: ... Light odor Intermediate Cycle Time Average odor Long Cycle Time Strong odour Refine Time setting optional by pressing the Up or Down blue arrow buttons to extend or to shorten the operation cycle time respectively Please refer to reference chart on page 13 Up to extend cycle time Down to shorten cycle time 6 66 666 Note Select length of cycle to correspond ...

Page 10: ...P a g e 10 10 Note Time is indicated on LCD in hours and minutes h hours and m minutes For example 3 hours and 20 minutes would be indicated so 3 h 20 m ...

Page 11: ...er keyboards rubber under the keys floor squeegees tubes for bicycles crepe soles for shoes rubber bands various gloves Latex smoked sheets underlay and more The common sense rule when in doubt about whether the item contains natural rubber remove the item before treating the space Or alternatively smear the item s surface with Vaseline or equivalent before exposing it to ozone Before starting ope...

Page 12: ...attach 4 diameter ducting to Super ActivO Outlet page 5 When using Super ActivO in this manner there will be no ozone deactivation However ozone in the crawl space will deactivate naturally typically in 3 6 hours The display will prompt you to Get Out of Room and the amber Hazard light will begin flashing You must leave the room immediately Windows and doors should be closed to prevent ozone leaka...

Page 13: ...peration Complete and the amber light should have stopped flashing After the operation has ended and before moving the machine elsewhere be sure to disconnect the power cord from the power socket STOP RESET O CAUTION In the event indications do not correspond to the above leave the room immediately and call for ECOZONE service If at any time you need to reset the keyboard settings press STOP butto...

Page 14: ...0 Medium 30 60m 3 6 22 30 34 24 60 268 90 360 Large 60 120m 3 20 38 60 126 52 180 1318 120 1440 X Large 120m 3 178 120 300 598 120 720 2698 180 2880 Keyboard Controlled Maximum Change From Default Time Up Up Down Short Inter Long Time minutes G D T G D T G D T Room Volume Small 30m 3 17 11 30 70 18 90 28 60 90 Medium 30 60m 3 21 22 45 154 24 180 88 90 180 Large 60 120m 3 50 38 90 666 52 720 598 12...

Page 15: ...e should take you about 1 hour We recommend first watching our video demonstration of the ActivO maintenance procedure http ecozone technologies com Products MobileGenerators ActivOVideos aspx CAUTION DISCONNECT POWER FROM THE SUPER ACTIVO BEFORE BEGINNING Step 1 Clean Dust Filter picture at bottom of this page a Remove black front grill panel by unscrewing 6 screws What you will then see is shown...

Page 16: ... B below Figure B d Place the filter under warm tap water and wash out dust It is ok to use a mild liquid soap if needed to loosen the dust Rinse and dry ok to use hair dryer e Slide Dust Filter back into its frame and retighten loosened screws Continued Next Page ...

Page 17: ...to remove and clean Figure C Singlet Core They are located side by side Figure D b Pull out the electrical cable of the Singlet core on the right side of Figure D and disconnect its electrical connector Video is very helpful c Unscrew the 2 nuts holding the Singlet unit red circles above ...

Page 18: ...g D g Drying may be done using a soft towel or in air h Re mount each Singlet core on its leading screws slide in parallel Be sure to re insert Singlets so that the 3 tubes are on the side facing you as shown in Figure C i Re attach the electrical connector to each Singlet core Be sure the connectors are dry j Re screw the two nuts onto each Singlet supporting screw Step 3 Close black front grill ...

Page 19: ...nnect power cord Wait for Ready prompt Ž Press STOP button red on keypad Press hard RESET button yellow on keypad Red light fault indication is ON and the display indicates one of the following fault codes a AL Presso Stat b AL Micro Switch Œ Make note of fault code indicated on the display Disconnect power cord Ž CALL ECOZONE service Display shows Needs Service This notification will appear every...

Page 20: ...ty Warranty period is 1 year commencing on the date of purchase Under this warranty Purchaser must first return the Super ActivO to ECOZONE together with proof of purchase from an authorized dealer of ECOZONE a Dealer either directly or through the Dealer from whom Purchaser purchased the Super ActivO for examination by ECOZONE of entitlement under the terms of this warranty All shipping handling ...

Page 21: ...SUCH DAMAGES IN NO EVENT SHALL LIABILITY UNDER THIS WARRANTY EXCEED THE PURCHASE PRICE OF THE SUPER ACTIVO PRODUCT SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS...

Reviews: