Features:

•   Integrated power supply: 100V or 150V selectable output 

for results in as little as 10 min.

•   Safe, high-intensity blue LED illumination: 470 nm wave-

length is optimized for SYBR® Safe and compatible with 

other popular nucleic acid stains.

•   Convenient 10 x 7 cm gel tray with two dual-sided 

combs for up to 16 samples per gel

•   Flexible gel volumes: 30-50 mL

•   Built-in timer: 1-99 minutes

•   Fan and ventilation system minimizes condensation 

during experiments

•   Convenient hinged lid contains dual automatic power 

cutoff switches for safety

•   Stainless steel and platinum electrodes are compatible 

with all standard electrophoresis buffers

•   17 x 17 x 15 cm

Voltage 

Selector

Timer

Screen

Increase/

Decrease

Timer

Start/Stop

Button

Summary of Contents for EDGE

Page 1: ...7 cm gel tray with two dual sided combs for up to 16 samples per gel Flexible gel volumes 30 50 mL Built in timer 1 99 minutes Fan and ventilation system minimizes condensation during experiments Convenient hinged lid contains dual automatic power cutoff switches for safety Stainless steel and platinum electrodes are compatible with all standard electrophoresis buffers 17 x 17 x 15 cm Voltage Sele...

Page 2: ...ned for safety and convenience A hinged lid and dual safety cutoff switches help to prevent im proper use and minimize the risk of electric shock The blue light transilluminator allows users to monitor DNA migration throughout the experiment using SYBR Safe or similar stains without the hazards associated with UV light 1 2 3 A built in power supply allows users to select between 100V and 150V prod...

Page 3: ...ophoresis chamber should sit flush against the bottom of the EDGE base unit 2 COVER the gel with 1x electrophoresis buffer being careful to not overfill the chamber For best results the buffer should be approximately 0 5 cm above the surface of the gel Ensure that the gel tray is aligned in the center of the chamber 3 LOAD the DNA samples into the wells according to the experiment protocol 4 LOWER...

Page 4: ... and outlet are func tional Confirm that the power switch on the rear of the EDGE base is turned on Inspect the fuse and replace if needed The fuse is located directly under the power plug on the rear of the EDGE The START STOP indicator LED does not stay lit and or the experiment does not run Ensure that the lid is fully closed Press firmly on the electrophoresis tank to ensure that it is firmly ...

Reviews: