Page 1: ...Body Fat Analyzer MBC 033 B User Manual ...

Page 2: ......

Page 3: ...NDED USE 5 PARTS 5 HARDWARE SET UP 6 eHealthyNet APP 6 MODE SETTING 9 MEASUREMENT 10 ABOUT BMI 12 ABOUT BODY FAT 13 ABOUT BODY WATER CONTENT 14 SPECIFICATION 15 SAFETY PRECAUTIONS 16 CARE MAINTENANCE 17 TROUBLESHOOTING 18 WARRANTY 19 EXPLANATION OF SYMBOL 20 ...

Page 4: ... technology to measure your body weight and cal culate your body composition such as body fat body fat visceral fat muscle mass bone mass Body Mass Index BMI and Basal Metablolic Rate BMR The analyzer works with your mobile device to track your data and share it with your family via eHealthyNet App PACKAGE CONTENT 1 eHealthyNet Body Fat Analyzer 1 User Manual 4 AAA Batteries ...

Page 5: ...t and compositions of a healthy adult individual The measurement result might not be optimal for children elderly pregnant or professional athlete Please follow the instruction of this user manual in order to use the anlayzer safely and properly The maximum weight can be measurred is 180kg 400lb PARTS LCD Screen Main Body Electrode Electrode ...

Page 6: ...s available in both Google Play and Apple App Store Before the first use of the monitor download the eHealthyNet App from Google Play and Apple Store Batteries Remove the battery cover Insert 4 AAA batteries into the compartment Battery Cover Unit Button Batttery Cover ...

Page 7: ... device 1 Switch bluetooth on under the Settings menu on IOS or Andriod devices 2 Select the Measure button in the main screen and then button in the upper right corner 3 Press and hold the Unit button in the back of the analyzer The machine displays and as the screen in next page showing that the pairing process is undergoing ...

Page 8: ...for the analyzer pairs with your mobile device it may last for 30 seconds If succeed the machine displays following screen If failed the screen displays the error sign 1 E1 also see the section TROUBLESHOOTING ...

Page 9: ... And Press Start Stop Button on the monitor to start measure ment MODE SETTING Measurement Unit Press Unit Button at the back of the analyzer when pow er is off the screen displays as the picturein the next page press Unit Button to switch between kilogram kg Stone st and Pound Ib units ...

Page 10: ...ent Take off your shoes and socks before measurements avoid use the analyzer after doing exercises Take Measurements with Mobile Devices 1 Switch on bluetooth launch the eHealthyNet App in your mobile device kilogram Pound Stone ...

Page 11: ...de vice Step on the analyzer to start measurements Note Stop the measurement process at any time by stepping down the analyzer The power will be automat ically switched off after 30 seconds of Idling 4 If you are taking measurement with bare feet the screen displays o mov ing from left to right wait until it stop 5 After the measurement the screen displays a bluetooth sign showing that the data is...

Page 12: ... BI have created the following guide to classify BMI of healthy adult individual BMI Classification BMI Color indicator Underweight 18 5 Cyan Normal 18 6 24 9 Green Overweight 25 59 9 Yellow Obesity I 30 34 9 Orange Obesity II 35 39 9 Orange Obesity III 40 RED ...

Page 13: ...ble Standard for Men Standard for Women Rating low Normal Moderately High High Age 20 29 13 14 16 17 18 14 20 15 21 17 23 18 24 19 25 21 23 22 24 24 26 25 27 26 28 23 24 26 27 28 30 39 40 49 50 59 60 Rating low Normal Moderately High High Age 20 29 19 20 21 22 23 20 28 21 29 22 30 23 31 24 32 29 31 30 32 31 33 32 33 33 35 31 32 33 34 35 30 39 40 49 50 59 60 ...

Page 14: ... intended to provide a basis for any type of emergency condition or diagnosis based on the color indicator these charts only depict different classification of BMI body fat and water Consult your physician to interprete the results properly Men Women BF RANGE 4 to 14 15 to 21 22 to 24 25 and over 4 to 20 21 to 29 30 to 32 33 and over 70 to 63 63 to 57 57 to 55 55 to 37 70 to 58 58 to 52 52 to 49 4...

Page 15: ...397lb Division 0 1kg 0 2lb Accuracy 50kg 0 3kg 150kg 0 5kg Working Environment Temperature 10 to 40 Humidity 15 90 RH Storage Environment Temperature 20 to 55 Power Source 6V Four AAA size Batteries Turn on Method SENSE ON technology Auto OFF Accessories 1 Four AAA size batteries 2 User Manual 100kg 0 4kg 180kg 0 7kg Mode of Operation Continuous Operation The scale will turn off after about 10 sec...

Page 16: ... the analyzer as it may lead to inaccurate result 4 Do not use the analyzer on the wet or slippy floor 5 Keep your feet dry while taking measurement 6 Do not drop the Analyzer or subject it to strong im pact 7 Replace all the batteries at once 8 Take out the batteries if the Analyzer will not be used in 3 months Patients having medical implants with electronic components such as pacemakers are nor...

Page 17: ...in the section SPECIFICATION Keep the analyzer away from high radiation device such as microwave oven CARE MAINTENANCE Cleaning the Monitor Clean the monitor with a piece of cloth soaked with de tegent Do not use any abrasive and volatile cleaning agent Maintenance 1 Do not load the analyzer if it is unused to prevent any damages 2 Always Keep the analyzer dry ...

Page 18: ...used in 3 months TROUBLESHOOTING Error Sign Error signs are displayed on the monitor s screen if there are abnormalities during measurement Sign Cause Correction Overloading Check if there is any object of this weight put on the analyzer Stop using the analyzer if you are of this weight consult your physician for any problem Pairing Error Follow the instruction of this manual and take measurements...

Page 19: ...sed in accor dance with the provided instructions The Warranty ex tends only to the end user We will at our option repair or replace without charge the eHealthyNet Body Fat An alyzer covered by the warranty Repair or replacement is our only responsiblity and your only remedy under the warranty Sign Cause Correction Low Battery Replace all the batteries at once ...

Page 20: ...posed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice Symbol for THE OPERATION GUIDE MUST BE READ Symbol for MANUFACTURER Symbol for SERIAL NUMBER Symbol for EUROPEAN REPRESENTATIVE Symbol for CE MARK Conforms to essential requirements of the Medical Device Directive 93 42 EEC ...