background image

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

USE AND INSTRUCTION MANUAL

USE AND INSTRUCTION MANUAL

USE AND INSTRUCTION MANUAL

USE AND INSTRUCTION MANUAL    

MOD

MOD

MOD

MODD

D

D

D....    E

EE

EKF 

KF 

KF 

KF 711

711

711

711    UD

UD

UD

UD    –

––

–    E

EE

EKF 

KF 

KF 

KF 664

664

664

664    UD

UD

UD

UD    –

––

–    EKF 

EKF 

EKF 

EKF 664 UD

664 UD

664 UD

664 UD----HT 

HT 

HT 

HT     

EKF 664 UD/003

EKF 664 UD/003

EKF 664 UD/003

EKF 664 UD/003    –

––

–    EKF 

EKF 

EKF 

EKF 616 UD

616 UD

616 UD

616 UD    –

––

–    EKF 

EKF 

EKF 

EKF 616 UD

616 UD

616 UD

616 UD----HT

HT

HT

HT

 

    
    

rev.

rev.

rev.

rev.    2

2

2

2    

 
 
 
 
 
 
 
 
 

TECNOEKA S.r.l. 

Via Marco Polo, n.11 - 35010 Borgoricco (Padova) Italy 

Tel. +39.049.9300344 – +39.049.5791479  Fax 049.5794387 

www.tecnoeka.com     E-mail: info@tecnoeka.com

 

 

Summary of Contents for EKF 616 U

Page 1: ...64 UD UD UD UD EKF EKF EKF EKF 664 UD 664 UD 664 UD 664 UD HT HT HT HT EKF 664 UD 003 EKF 664 UD 003 EKF 664 UD 003 EKF 664 UD 003 EKF EKF EKF EKF 616 UD 616 UD 616 UD 616 UD EKF EKF EKF EKF 616 UD 616 UD 616 UD 616 UD HT HT HT HT rev rev rev rev 2 2 2 2 TECNOEKA S r l Via Marco Polo n 11 35010 Borgoricco Padova Italy Tel 39 049 9300344 39 049 5791479 Fax 049 5794387 www tecnoeka com E mail info t...

Page 2: ...l page 2 __________________________________________________________________________________________ X Sgq PRODOTTI 1 FORNI FORNO ELETTRICO LEka MANUALI D USO Forno Elettrico 40 60 90 LEka Lingua Inglese NUOVA GAMMA EF Instruction manual EKF 711 UD EKF 664 UD HT EKF 664 UD_003 EKF 616 UD HT GB rev 2 doc ...

Page 3: ...1 UD 711 UD 711 UD 711 UD EKF 664 UD EKF 664 UD EKF 664 UD EKF 664 UD EKF 664 UD EKF 664 UD EKF 664 UD EKF 664 UD HT HT HT HT EKF 664 UD 003 EKF 664 UD 003 EKF 664 UD 003 EKF 664 UD 003 EKF 616 UD EKF 616 UD EKF 616 UD EKF 616 UD EKF EKF EKF EKF 616 UD 616 UD 616 UD 616 UD HT HT HT HT TECNOEKA Srl declares that the mentioned above products meet the following safety regulations Low voltage directiv...

Page 4: ..._____________________________ Index Index Index Index 1 Technical service 2 General warnings 3 Technical specifications 4 Instructions for the installer 5 Use instructions for the user 6 Residual risks for the user 7 How to use the control panel 8 Oven cooking 9 Cleaning 10 Maintenance 11 Technical service 12 Information to the consumers 13 Wiring layout 14 The Warranty ...

Page 5: ... instructions shall release Improper or incorrect use and failure to observe the installation instructions shall release Improper or incorrect use and failure to observe the installation instructions shall release the manufacture from all responsibility the manufacture from all responsibility the manufacture from all responsibility the manufacture from all responsibility In this connection the dir...

Page 6: ...tion make sure of the following the voltage and frequency values of the power supply system match the values on the technical data plate affixed on the appliance the limiting valve and the system are able to support the appliance s load see the technical data plate the power sup the power sup the power sup the power supply system has an adequate earth connection according to current legal ply syst...

Page 7: ...te system thus stopping the steam coming back out of the drain FIG FIG FIG FIG 1 1 1 1 FIG FIG FIG FIG 2 2 2 2 Connecting the power cable Connecting the power cable Connecting the power cable Connecting the power cable for modd EKF 711 UD EKF 664 UD HT EKF 616 UD HT To reach the power terminal board remove the left side of the appliance Loosen the cable clamp on the back at the bottom of the appli...

Page 8: ...h reduced phycal sensory or mental capabilities or lack of experience and knowledge Unless they have beengiven supervision or instruction concerning use of appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance For first use we advise you to let the appliance to run load free at maximum temperature for about one hour In t...

Page 9: ...__________________ page 9 7 7 7 7 How to use the control panel How to use the control panel How to use the control panel How to use the control panel 1 End of cooking programming knob 2 Control thermostat knob 3 Automatic humidifier knob 4 End of cooking programmer indicator light 5 Control thermostat indicator light 6 Automatic humidifier indicator light 1 2 3 4 5 6 ...

Page 10: ...he temperature inside the cooking compartment at a value of at least 110 C order to optimise vapour production End of cooking programmer indicator light End of cooking programmer indicator light End of cooking programmer indicator light End of cooking programmer indicator light The programmer green indicator light indicate that the oven is operating and that cooking time is active Control thermost...

Page 11: ...ng outward In all cases you may just use tepid soapy water After rinsing thoroughly dry the glass surface with a soft cloth If opaque sections form between the two glass panels of the door they can be eliminated after dismantling the internal glass panel Cleaning the fans Cleaning the fans Cleaning the fans Cleaning the fans The fans must be periodically cleaned with specific anti lime scale produ...

Page 12: ...rrective action Control panel completely off the oven does not work Incorrect electric connections to the mains Check the mains connection No mains voltage Restore mains voltage Thermal break safety device tripped Reset the thermal break safety device Cooking cycle set the oven does not work Door open or ajar Close the door Damaged magnetic sensor Contact a qualified technician to repair the senso...

Page 13: ...ser can contact Tecnoeka by calling the telephone numbers on the cover or going to www tecnoeka com www tecnoeka com www tecnoeka com www tecnoeka com 12 12 12 12 Informations to the consumers Informations to the consumers Informations to the consumers Informations to the consumers Further to Directive 2002 96 EC the symbol of the crossed rubbish skip on the appliance means that at the end of its ...

Page 14: ...EKF 616 UD EKF 616 UD EKF 616 UD EKF 616 UD HT HT HT HT Key Key Key Key M Power terminal board Pr End of cooking programmer T1 Safety thermostat T2 Oven thermostat U Automatic humidifier S1 Programmer indicator light S2 Thermostat indicator light S3 Automatic humidifier indicator light IM Operating direction reversing element MI Door microswitch E Solenoid valve for automatic humidifier B1 B2 B3 B...

Page 15: ...nal board Pr End of cooking programmer T1 Safety thermostat T2 Oven thermostat U Automatic humidifier S1 Programmer indicator light S2 Thermostat indicator light S3 Automatic humidifier indicator light IM Operating direction reversing element MI Door microswitch E Solenoid valve for automatic humidifier B1 B2 Contactor coil B R Contactor Relais T Transformer for oven lamp L Oven lighting lamp V1 V...

Page 16: ...justments and or maintenance and or repairs carried out by unauthorised personnel and or with non original spare parts 8 inadequate or careless maintenance of the product in contrast with the user s handbook supplied with the product 9 damages caused by fire natural disasters and accident as well as by any cause not attributable to TECNOEKA SRL The warranty explicitly excludes The warranty explici...

Reviews: