INSTALLATION & USER INSTRUCTIONS

All instructions must be handed to the user for

safekeeping.

WALL MOUNTED HIGH EFFICIENCY GAS FIRE

Please  note  :  Except  where  otherwise  stated,  all  rights,

including  copyright  in  the  text,  images  and  layout  of  this

booklet is owned by Focal Point Fires plc.  You are not per-

mitted  to  copy  or  adapt  any  of  the  content  without  the

prior written permission of Focal Point Fires plc. 

1

Revision D - 07/16

The products covered by this booklet are protected under

patent GB2275331C.

GB IE

© 2016 Focal Point Fires plc.

MODEL SHOWN: EKO 5070 GAS FIRE

MODELS COVERED BY THESE INSTRUCTIONS
5070  GAS FIRE

Christchurch, Dorset BH23 2BT

Tel: 01202 588 638     

Fax: 01202 499 639

www.ekofires.co.uk

e-mail: sales@ekofires.co.uk

Summary of Contents for eko 5070

Page 1: ...Focal Point Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc 1 Revision D 07 16 The products covered by this booklet are protected under patent GB2275331C GB IE 2016 Focal Point Fires plc MODEL SHOWN EKO 5070 GAS FIRE MODELS COVERED BY THESE INSTRUCTIONS 5070 GAS FIRE Christchurch Dorset BH23 2BT Tel 01202 588 638 Fa...

Page 2: ...nce is intended as a secondary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first light up of a new appliance burning off of high temperature paint and lubri cants may occur for the first few hours of operation Durin...

Page 3: ...o normal gentle draughts experienced within the home It is not recommended however that the appliance be installed in areas where it is likely to be directly exposed to persistent strong draughts that may be generated by outside doors windows air vents air conditioning units extractor fans ceiling fans etc See section 4 1 for more information on ventilation Clearances to non combustible materials ...

Page 4: ...y cause cracking along the joint line If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important in these circumstances that any vapour control bar rier is not damaged and that any structural members of the house frame are not damaged refer to section 7 ...

Page 5: ... only on a vertical surface Avoid sloped surfaces Installation onto anything other than a vertical wall may result in fire damage or injury If the appliance is to be mounted on the inner leaf of a conventional cavity brick wall or a solid wall then the wall plugs and fixing screws provided may be used Depending on the condition of the wall it may be necessary to use additional fixings In this situ...

Page 6: ...r approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push the control knob in slightly and continue turning anti clockwise to the high position The main burn er should light after a few seconds To decrease the setting to LOW push the knob in sl...

Page 7: ...e glass facia assembly Removal is reverse of section 8 3 3 Remove the glass door assembly 4 screws and clean carefully 4 Inspect the burner and the catalyst and clean if necessary with a soft brush 5 Disconnect the gas supply 6 Undo the four screws retaining the burner support brackets to the base and rear of the firebox Remove the control knob and spindle assembly from the valve by removal of the...

Page 8: ... dirt during routine servicing procedures The expect ed life of the catalysts is in excess of 11 000 hours 10 years of normal use After this time the catalysts should be replaced If there are any deposits of dirt or soot on the catalyst they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals are in good condition before replacing the catalyst New seal...

Page 9: ...ere is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there could be a problem with contamination of the gas supply drafts room size and or ventilation or the thermocouple needs replacement Modifications are dangerous an...

Page 10: ...the catalyst is in excess of 11 000 hours 10 years of normal use After this time the catalyst should be replaced Should any home improvements be carried out to the property after the fire is installed such as installation of extractor fans for example the fire should be re checked by a competent person for safe operation U S E R I N S T R U C T I O N S 2 0 CLEARANCES TO COMBUSTIBLES Section Conten...

Page 11: ...moveable and can be used with open fires including combination grates or closed fires including room heaters and stoves See figures 2 3 for fireguard examples The fireguards specified are not intended to reduce the risk of fires caused by flying particles which are covered by BS 3248 Purpose provided ventilation of 100cm2 MUST be provided for this appliance An openable window or equivalent is also...

Page 12: ...afety system may be in operation Switch the appliance OFF call in your installer to check the appliance and ventilation Remedial work must be carried out as required DO NOT allow the appli ance to be used until the appliance and installation is passed as safe If the pilot continues to be extinguished you must call your installer to check the operation of the complete appliance Before carrying out ...

Page 13: ... GAS SAFE registration No Model Fire serial No Name contact details of installer Supplied by 4 GB IE Date installed 11 0 SERVICE HISTORY Date of service Serviced by name Contact details of Engineer GAS SAFE No 2016 Focal Point Fires plc ...

Page 14: ... by Gas Safe registered installer evidence of which must be provided such as the receipt 4 Purchase s must be made through an authorised stockist retailer Please note all consumable items such as any ceramics including coals pebbles the matrix front strips side cheeks rear panels and tapered rear panels are not covered by the 3 year guarantee During the guarantee period any product or component wh...

Page 15: ...A A B C D E F G 2015 1186 kW ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE A A A A A A EKO Fires L30 Flueless Gas Fire 2 3 ...

Page 16: ...is appliance must be installed commissioned and maintained by a competent person Prior to installation the competent person must ensure that the local distribution conditions identification of the type of gas and pressure and adjustment of the appliance are compatible This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space of adequate...

Page 17: ... 0 kW single stage heat output no room temperature control yes no At minimum heat output elmin 0 0 kW two or more manual stages no room temperature control yes no In standby mode elSB 0 0 kW with mechanic thermostat room temperature control yes no with electronic room temperature control yes no with electronic room temperature control plus day timer yes no with electronic room temperature control ...

Page 18: ...A A B C D E F G 2015 1186 kW ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE A A A A A A EKO Fires Fire LPG L30 Flueless Gas 2 0 ...

Page 19: ...is appliance must be installed commissioned and maintained by a competent person Prior to installation the competent person must ensure that the local distribution conditions identification of the type of gas and pressure and adjustment of the appliance are compatible This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space of adequate...

Page 20: ... 0 kW single stage heat output no room temperature control yes no At minimum heat output elmin 0 0 kW two or more manual stages no room temperature control yes no In standby mode elSB 0 0 kW with mechanic thermostat room temperature control yes no with electronic room temperature control yes no with electronic room temperature control plus day timer yes no with electronic room temperature control ...