background image

 
 

 
 

 

 

 

 

 

 

 

 

 

ACL BAR™ 

user manual

   

   

E

LA

TI

ON

 

|

 

A

C

L BA
R

 

|

 

u

se

r m

an
u

al

 

Summary of Contents for ACL BAR

Page 1: ...ACL BAR user manual E L A TI ON ACL BAR user manual ...

Page 2: ...ON PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation ...

Page 3: ... 1 C O N T E N T S General Information 4 Warranty 6 Safety Instructions 7 General Guidelines 8 Fixture Overview 9 Fixture Installation 10 Fixture Menu 12 DMX Channel Functions And Values 15 Cleaning and Maintenance 20 Technical Specifications 21 Optional Accessories 23 ...

Page 4: ...ing use and maintenance UNPACKING Every fixture has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found...

Page 5: ...chase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must pro...

Page 6: ...er by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Elation Professional will replace defective parts at its expense and will absorb all expense...

Page 7: ...stallation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Any modifications will void the original manufactures warranty and increase the risk of damage and or personal injury Never look directly into the light source of thi...

Page 8: ...ent surfaces Be sure no air ventilation slots are blocked DO NOT attempt installation and or operation without knowledge how to do so DO NOT permit operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent operational breaks may ensure the fixture will function properly for many years to come DO NOT shake fix...

Page 9: ...ACL BAR User Manual Ver 1 F I X T U R E O V E R V I E W 1 LCD Control Display 6 NET IN RJ45 Ethernet 2 MODE UP DOWN ENTER Buttons 7 NET OUT RJ45 Ethernet 3 Fuse 8 3pin 5pin DMX OUT 4 powerCON IN 9 powerCON OUT 5 3pin 5pin DMX IN 1 2 3 4 6 7 8 9 5 ...

Page 10: ... C Do not use the fixture under or above this temperature Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing MOUNTING P...

Page 11: ...a suspended environment to ensure the fixture will not drop if the clamp fails POWER LINKING Max number of units that can be power linked is 9 units 110V and 16 units 240V CLAMP MOUNTING The fixture provides an integrated mounting bracket yoke Make sure to secure an appropriately rated clamp to the mounting bracket using M10 screws when mounting this fixture to truss ...

Page 12: ...ess the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field Pressing the ENTER button once more will confirm your setting You may exit the main menu at any time w...

Page 13: ... Strobe 000 Set RGBW Strobe values manually for ALL 7 LEDs Macros 00 64 Set Color Macro Fan Set Fan Speed Auto High Low Set Fan Speed LCD Set Blacklight 02S 60S 05S LCD Display Shutoff Time Key Lock OFF Set Control Display Key Lock Feature DispFlash ON LCD Display flashes when NO Signal is detected Temp F C Set temperature to F C DFSE OFF ON Restore Factory Settings Info Time Info Current 0000H La...

Page 14: ... Ver 1 Dim Curve Select desired DIMMER MODE Standard Stage TV Architectural Theatre Pixel Flip Select the desired starting LED and chase direction from one of the following modes below via UP DOWN buttons and then press ENTER to confirm Default OFF Flip OFF Flip ON ...

Page 15: ...3 3 3 3 3 BLUE LED All LEDs 1 7 0 255 Blue 0 Black 255 100 4 4 4 4 4 WHITE LED All LEDs 1 7 0 255 White 0 Black 255 100 1 1 1 1 RED LED LED 1 0 255 Red 0 Black 255 100 2 2 2 2 GREEN LED LED 1 0 255 Green 0 Black 255 100 3 3 3 3 BLUE LED LED 1 0 255 Blue 0 Black 255 100 4 4 4 4 WHITE LED LED 1 0 255 White 0 Black 255 100 5 5 5 5 RED LED LED 2 0 255 Red 0 Black 255 100 6 6 6 6 GREEN LED LED 2 0 255 ...

Page 16: ...255 100 16 16 16 16 WHITE LED LED 4 0 255 White 0 Black 255 100 17 17 17 17 RED LED LED 5 0 255 Red 0 Black 255 100 18 18 18 18 GREEN LED LED 5 0 255 Green 0 Black 255 100 19 19 19 19 BLUE LED LED 5 0 255 Blue 0 Black 255 100 20 20 20 20 WHITE LED LED 5 0 255 White 0 Black 255 100 21 21 21 21 RED LED LED 6 0 255 Red 0 Black 255 100 22 22 22 22 GREEN LED LED 6 0 255 Green 0 Black 255 100 23 23 23 2...

Page 17: ... Color Macro 03 13 16 Color Macro 04 17 20 Color Macro 05 21 24 Color Macro 06 25 28 Color Macro 07 29 32 Color Macro 08 33 36 Color Macro 09 37 40 Color Macro 10 41 44 Color Macro 11 45 48 Color Macro 12 49 52 Color Macro 13 53 56 Color Macro 14 57 60 Color Macro 15 61 64 Color Macro 16 65 68 Color Macro 17 69 72 Color Macro 18 73 76 Color Macro 19 77 80 Color Macro 20 81 84 Color Macro 21 85 88 ...

Page 18: ...40 161 164 Color Macro 41 165 168 Color Macro 42 169 172 Color Macro 43 173 176 Color Macro 44 177 180 Color Macro 45 181 184 Color Macro 46 185 188 Color Macro 47 189 192 Color Macro 48 193 196 Color Macro 49 197 200 Color Macro 50 201 204 Color Macro 51 205 208 Color Macro 52 209 212 Color Macro 53 213 216 Color Macro 54 217 220 Color Macro 55 221 224 Color Macro 56 225 228 Color Macro 57 229 23...

Page 19: ...BIT 0 256 1 to 100 8 9 32 AUTO PROGRAMS 0 NO FUNCTION 1 20 PROGRAM MACRO 01 21 40 PROGRAM MACRO 02 41 60 PROGRAM MACRO 03 61 80 PROGRAM MACRO 04 81 100 PROGRAM MACRO 05 101 120 PROGRAM MACRO 06 121 140 PROGRAM MACRO 07 141 160 PROGRAM MACRO 08 161 180 PROGRAM MACRO 09 181 200 PROGRAM MACRO 10 201 220 PROGRAM MACRO 11 221 240 PROGRAM MACRO 12 241 250 PROGRAM MACRO 13 251 255 PROGRAM MACRO 14 9 10 3...

Page 20: ...efer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating Be sure all ...

Page 21: ...el Modes 1CH 04 2CH 04 6 8 10 12 28 30 32 35 RDM Remote Device Management 6 Button Touch Control Panel Full Color 180 Reversible LCD Menu Display 8 16 Bit Resolution Adjustable Movement 3pin 5pin DMX In Out RJ45 Ethernet In Out KlingNET Art NET powerCON Power In Out SIZE WEIGHT Length 21 6 550mm Width 9 5 241 2mm Glare Shield Installed Vertical Height 6 8 172 5mm Weight 15 0 lbs 6 8 kg ELECTRICAL ...

Page 22: ...g h t i n g c o m 22 ACL BAR User Manual Ver 1 PHOTOMETRIC DATA DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice ...

Page 23: ...DER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp EWDMXSYSTEM Wireless DMX System 1 Transmitter 1 Receiver CAT005 5 1 5m CAT6 EtherCON Cable PLC3 3 ft 1m PowerCON PRO Link Cable AC3PDMX5PRO 5 ft 1 5m 3pin PRO DMX Cable AC5PDMX5PRO 5 ft 1 5m 5pin PRO DMX Cable Additional Cable Lengths Available ...

Page 24: ......

Reviews: