background image

 
 

 
 

 

 

 

 

 

 

ARENA ZOOM Q7IP™ 

user manual

 

 

E

LA

TI

ON

 

|

 

A

RE

N

A

 Z

OOM

 Q7
IP

 

|

 

u

se

r m

an
u

al

 

Summary of Contents for ARENA ZOOM Q7IP

Page 1: ...ARENA ZOOM Q7IP user manual E L A TI ON ARENA ZOOM Q7IP user manual ...

Page 2: ...uipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 83...

Page 3: ...E N T S General Information 4 Warranty 7 Safety Instructions and Guidelines 8 Overview 10 Installation 11 System Menu 14 DMX Channel Functions And Values 17 Cleaning and Maintenance 19 Technical Specifications 20 Optional Accessories 21 ...

Page 4: ...he fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ingress of dust 6 and high pressure water jets from any direction 5 M A R I N E C O A S T A L E N V I R O N M E N T I N S T A L L A T I O N S Please note although this fixture is IP rat...

Page 5: ...tomer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS powerCON TRUE1 Cable CUSTOMER SUPPORT Elation Professional provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elatio...

Page 6: ...included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will be refused and returned at customer s expense You may obtain a R A number by contacting customer support I M P O R T A N T N O T I C E There are no user serviceable parts inside this unit Do ...

Page 7: ...onal if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service...

Page 8: ...r installation Any modifications to the fixture and or the mounting hardware included will void the original manufactures warranty and increase the risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED DO NOT CONNECT GOBO ROTATOR CABLE TO FIXTURE WHEN FIXTURE IS POWERED ON DO NOT PLUG FIXTURE INTO A DIMMER PACK NEVER OPEN THIS FIXTURE WHILE IN USE UNPLUG POWER ...

Page 9: ...no less than M10 x 25 mm and always install fixture with an appropriately rated safety cable Always disconnect fixture from main power source before performing any type of service and or cleaning procedure Only handle the power cord by the plug end never pull out the plug by tugging the wire portion of the cord During the initial operation of this fixture a light smoke or smell may emit from the i...

Page 10: ...www elationlighting com 10 O V E R V I E W 1 OLED Menu Control Display 2 Menu Up Down Enter Buttons 3 IP Rated 5pin DMX IN 4 IP Rated 5pin DMX OUT 5 powerCON TRUE1 IN 6 powerCON TRUE 1 OUT ...

Page 11: ...ixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 14 to 113 F 10 to 45 C Do not use the fixture under or above this temperature Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture Fixture...

Page 12: ...XTURES MAY EXCEED THE MAX OUTPUT ON THIS FIXTURE CLAMP MOUNTING This fixture includes an adjustable mounting yoke and safety cable rigging point attached to the fixture see the illustration below When mounting this fixture to truss be sure to secure an appropriately rated clamp not included to the yoke using an M10 screw and attach a SAFETY CABLE to the fixture safety cable rigging point SAFETY CA...

Page 13: ... installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully operational in the specific mounting positions illustrated below S A F E T Y C A B L E ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE C...

Page 14: ...al operation pressing MENU button once will access the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field Pressing the ENTER button once more will confirm your s...

Page 15: ...enes To Use Scenes 1 4 Set by Default Scene 1 Red 255 Scene 2 Green 255 Scene 3 Blue 255 Scene 4 White 255 Edit Scene Colors 1 x Red 0 255 Green 0 255 Blue 0 255 White 0 255 Edit RGBW Values for Scenes Edit Function ONLY Available for Scene Numbers Accessed in Total Scenes Menu Fade Time 0 255 secs 4 Set Transition Time Between Scenes Hold Time 0 255 secs 8 Set Length of Time Scenes Are Displayed ...

Page 16: ...www elationlighting com 16 Dimmer Curve Modes Select dimming modes Standard Stage TV Architectural Theatre ...

Page 17: ... LEE 071 Tokyo Blue 050 054 LEE 120 Deep Blue 055 059 LEE 079 Just Blue 060 064 LEE 132 Medium Blue 065 069 LEE 200 Double CT Blue 070 074 LEE 161 Slate Blue 075 079 LEE 201 Full CT Blue 080 084 LEE 202 Half CT Blue 085 089 LEE 117 Steel Blue 090 094 LEE 353 Lighter Blue 095 099 LEE 118 Light Blue 100 104 LEE 116 Medium Blue Green 105 109 LEE 124 Dark Green 110 114 LEE 139 Primary Green 115 119 LE...

Page 18: ...EDs ON 128 159 Pulse Effect SLOW to FAST 160 191 LEDs ON 192 223 Random Strobe SLOW to FAST 224 255 LED ON N A 5 5 7 7 8 DIMMER INTENSITY 0 255 Intensity 0 to 100 N A N A 6 N A 8 9 DIMMER INTENSITY FINE 0 255 Dimmer Intensity FINE Adjustment 5 6 7 8 9 10 ZOOM 0 255 NARROW to WIDE N A N A N A N A 10 11 DIMMER CURVES 0 20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THRATRE 101 255 DEFAU...

Page 19: ... issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners a...

Page 20: ...ONTROL CONNECTIONS 3 DMX Channel Modes 3 6 8 5 Multiple DMX Channel Modes 12 total channels Adjustable Refresh Rate 600 28 800 Hz Adjustable Gamma Brightness 2 0 2 2 2 4 2 8 4 Button 180 Reversible OLED Menu Control Display DMX and RDM Protocol Support IP Rated 5pin DMX In Out powerCON TRUE1Power In Out SIZE WEIGHT Length 12 4 316mm Width 9 6 245mm Vertical Height 7 8 197mm Weight 19 0 lbs 8 6kg E...

Page 21: ...ments in the design of this unit and this manual are subject to change without any prior written notice O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM QUICK RIG CLAMP Low Profile Quick Release Clamp NEU088 3 ft 1m powerCON TRUE1 Power Link Cable Additional Cable Lengths Available ...

Page 22: ......

Reviews: