COPYRIGHT

Electrex is a trademark of Akse S.r.l. All rights reserved.
It is forbidden to duplicate, adapt, transcript this document without Akse written authorization, 
except when regulated accordingly by the Copyright Laws.

WARRANTY 

This product is covered by a warranty against material and manufacturing defects for a 
period of 24 months period from the manufacturing date.
The warranty does not cover the defects that are due to: 
• Negligent and improper use  
• Failures caused by atmospheric hazards 
• Acts of vandalism 
• Wear out of materials
• Firmware upgrades
Akse reserves the right, at its discretion, to repair or substitute the faulty products   
The warranty is not applicable to the products that will result defective in consequence of a 
negligent and improper use or an operating procedure not contemplated in this manual. 

RETURN AND REPAIR FORMALITIES

  

Akse accepts the return of instruments for repair only when authorized in advance. The 
transport costs are at customer charge. 

RE-SHIPPING OF REPAIRED PRODUCT

  

The terms for re-shipment of repaired products are ex-works, i.e. the transport costs are 
at customer charge.
Products returned as detective but found to be perfectly working by our laboratories, will 
be charged a fl at fee to account for checking and testing time irrespective of the warranty 
terms.

SAFETY

 

This  instrument  was  manufactured  and  tested  in  compliance  with  IEC  61010  class  2 
standards  for operating voltages up to 250 VAC rms phase to neutral. 
In order to maintain this condition and to ensure safe operation, the user must comply with 
the indications and markings contained in the following instructions: 

• When the instrument is received, before starting its installation, check that it is 

intact and no damage occurred during transport. 

•  Before  mounting,  ensure  that  the  instrument  operating  voltages  and  the  mains 

voltage are compatible then proceed with the installation. 

• The instrument power supply needs no earth connection. 
•  The  instrument  is  not  equipped  with  a  power  supply  fuse;  a  suitable  external 

protection fuse must be foreseen by the contractor. 

•  Maintenance  and/or  repair  must  be  carried  out  only  by  qualifi ed,  authorized 

personnel 

• If there is ever the suspicion that safe operation is no longer possible, the instrument 

must be taken out of service and precautions taken againstits accidental use. 

• Operation is no longer safe when:

1) There is clearly visible damage. 
2) The instrument no longer functions. 
3) After lengthy storage in unfavorable conditions. 
4) After serious damage occurred during transport

The instruments must be installed in respect of all the local regulations.

OPERATOR SAFETY

Warning:

  Failure  to  observe  the  following  instructions  may  lead  to  a  serious  danger  of 

death.

• During normal operation dangerous voltages can occur on instrument terminals and 

on  voltage  and  current  transformers.  Energized  voltage  and  current  transformers 
may generate lethal voltages. Follow carefully the standard safety precautions while 
carrying out any installation or service operation.

• The terminals of the instrument must not be accessible by the user after the installation. 

The  user  should  only  be  allowed  to  access  the  instrument  front  panel  where  the 
display is located.

• Do not use the digital outputs for protection functions nor for power limitation functions. 

The instrument is suitable only for secondary protection functions.

• The instrument must be protected by a breaking device capable of interrupting both 

the power supply and the measurement terminals. It must be easily reachable by the 
operator and well identifi ed as instrument cut-off  device.

• The instrument and its connections must be carefully protected against short-circuit.

Precautions:

 Failure to respect the following instructions may irreversibly damage to the 

instrument.

• The instrument is equipped with PTC current limiting device but a suitable external 

protection fuse should be foreseen by the contractor.

• The outputs and the options operate at low voltage level; they cannot be powered by 

any unspecifi ed external voltage.

• The application of currents not compatible with the current inputs levels will damage 

to the instrument.

Further documentation may be downloaded from our web site www.electrex.it.

This document is owned by company AKSE that reserves all rights. 

DECLARATION OF CONFORMITY

 

Akse hereby declares that its range of products complies with the following directives EMC
2014/30/EU, 2014/35/EU and complies with the following product’s standard CEI EN
61326 - Ed. 2.0 (2012) – IEC 61326 - Ed. 2.0 (2012), CEI EN 61010- Ed. 3 (2010) – IEC
61010- Ed. 3 (2010). The product has been tested in the typical wiring confi  guration and
with peripherals conforming to the EMC directive and the LV directive.

!

ATTO D4

INSTALLATION INSTRUCTIONS

The instrument is programmed with the following default values:

PAGE

MENU DISPLAYED

AVAILABLE PARAMETERS

DEFAULT

PASSWORD

0000 ... 9999

0000

RS485

RS 485 ADDRESS

1 ... 247

27

Comm. Speed

2400, 4800, 9600, 19200, 38400

38400

Data Bit

7 o 8

8

Parity

N = no parity, E =even parity, O = odd parity

N

Bit of stop

1 o 2

2

NETWORK

Type

 

(note n.1)

3PH-3W-2CT, 3PH-4W, 2PH-2W, 1PH-2W

3PH-4W

Export

NO, YES

NO

CT

10000/1 o 5

5/5

VT

400000/300

1/1

AVG-MD TIME 

(note n.2)

POWERS

1...60 (minutes)

15

CURRENTS

1...60 (minutes)

8

ALARM 1 / A

 (

note n.11)

MODE (

note n.3)

Normal, 1-OF-3, 3-OF-3, DERIV, UNBAL

NORMAL

TYPE (

note n.4)

MAX, MIN

MIN

MEAS (

note n.5)

Controlled measure. See table n.1 for register 
selection

200

THRE (

note n.5)

Threshold value

0

ALARM 1 / B

HYST

1...100 (%)

1

DELAY

1...99 (seconds)

1

AVG (

note n.6)

1...99 (seconds)

1

OUT (

note n.7)

Normal, Hold, Pulse-L, Pulse-S

NORMAL

ALARM 2 / A

 (

note n.11)

MODE (

note n.3)

Normal, 1-OF-3, 3-OF-3, DERIV, UNBAL

NORMAL

TYPE (

note n.4)

MAX, MIN

MIN

MEAS (

note n.5)

Controlled measure. See table n.1 for register 
selection

200

THRE (

note n.5)

Threshold value

0

ALARM 2 / B

HYST

1...100 (%)

1

DELAY

1...99 (seconds)

1

AVG (

note n.6)

1...99 (seconds)

1

OUT (

note n.7)

Normal, Hold, Pulse-L, Pulse-S

NORMAL

ALARM 3 / A

 (

note n.11)

MODE (

note n.3)

Normal, 1-OF-3, 3-OF-3, DERIV, UNBAL

NORMAL

TYPE (

note n.4)

MAX, MIN

MIN

MEAS (

note n.5)

Controlled measure. See table n.1 for register 
selection

200

THRE (

note n.5)

Threshold value

0

ALARM 3 / B

HYST

1...100 (%)

1

DELAY

1...99 (seconds)

1

AVG (

note n.6)

1...99 (seconds)

1

OUT (

note n.7)

Normal, Hold, Pulse-L, Pulse-S

NORMAL

ALARM 4 / A

 (

note n.11)

MODE (

note n.3)

Normal, 1-OF-3, 3-OF-3, DERIV, UNBAL

NORMAL

TYPE (

note n.4)

MAX, MIN

MIN

MEAS (

note n.5)

Controlled measure. See table n.1 for register 
selection

200

THRE (

note n.5)

Threshold value

0

ALARM 4 / B

HYST

1...100 (%)

1

DELAY

1...99 (seconds)

1

AVG (

note n.6)

1...99 (seconds)

1

OUT (

note n.7)

Normal, Hold, Pulse-L, Pulse-S

NORMAL

DIGITAL OUT 1

 (

note n.8)

MODE

PULSE, ALARM, REMOTE

PULSE

POLARITY

NO, NC

NO

PULSE OUT 1

MEAS (

note n.9)

P-IMP, QL-IMP, QC-IMP, S-IMP, P-EXP,
QL-EXP, QC-EXP, S-EXP

P-IMP

PRIMARY (

note n.10)

YES, NO

YES

WEIGHT

1...100000000 (Wh/100)

100000

WIDTH

50ms...1S

500

DIGITAL OUT 2

 (

note n.8)

MODE

PULSE, ALARM, REMOTE

PULSE

POLARITY

NO, NC

NO

PULSE OUT 2

MEAS (

note n.9)

P-IMP, QL-IMP, QC-IMP, S-IMP, P-EXP,
QL-EXP, QC-EXP, S-EXP

QL-IMP

PRIMARY (

note n.10)

YES, NO

YES

WEIGHT

1...100000000 (Wh/100)

100000

WIDTH

50ms...1S

500

MECHANICAL CHARACTERISTICS

Enclosure

Self-extinguishing plastic material class V0

Protection degree

IP40 on front panel

Dimensions

70 x 90 x 58 mm (4 DIN modules)

VOLTAGE INPUT

Direct

Up to 300 Vrms phase-neutral or 519 Vrms phase to phase

With external PT(VT)

Primary: programmable (max. 400 kV)
Secondary: programmable (max. 300 V)
Overload: 900 Vrms phase to phase for 1 sec

Power supply

230//- 10% 50/60Hz

Self consumption

< 3VA

MODELS

PFA7411-02

ATTO D4 RS485 230-240V
TRANSDUCER / ANALYZER

PFA7411-12

ATTO D4 RS485 230-240V 1DI 2DO
TRANSDUCER / ANALYZER

Summary of Contents for ATTO D4

Page 1: ...cautions Failure to respect the following instructions may irreversibly damage to the instrument The instrument is equipped with PTC current limiting device but a suitable external protection fuse should be foreseen by the contractor The outputs and the options operate at low voltage level they cannot be powered by any unspecified external voltage The application of currents not compatible with the...

Page 2: ...r or Tariff T2 Ea P kWh 10 438 2 I Total exported inductive energy Partial Counter or Tariff T2 Er Ind P kvarh 10 440 2 I Total exported capacitive energy Partial Counter or Tariff T2 Er Cap P kvarh 10 442 2 I Total exported apparent energy Partial Counter or Tariff T2 Es P kVAh 10 444 2 I Phase imported active energy Ea L1 kWh 10 446 2 I Phase imported active energy Ea L2 kWh 10 448 2 I Phase importe...

Page 3: ...e average value AVG and peak value MD for current from 1 to 60 minutes Note n 3 Normal Classic Alarm with reference to a fixed threshold or to maximum and minimum delay and applicable hysteresis AVG parameter is not used 1 OF 3 Consider also the 2 following registers of the selected one in MEAS Works on a fixed max or min threshold with delay and applicable hysteresis If one of the three register ex...

Page 4: ... errors VOLTAGE AND CURRENT CONNECTION S1 S2 S1 S2 S1 S2 A B T 10 11 12 17 18 19 20 U1 U2 U3 N I1 I2 I3 RS 485 AUX AUX VOLTAGE INPUT POWER S1 S2 P1 P2 L1 L2 L3 N S1 S2 P1 P2 S1 S2 P1 P2 S1 S2 S1 S2 S1 S2 A B T 10 11 12 17 18 19 20 U1 U2 U3 N I1 I2 I3 RS 485 AUX AUX VOLTAGE INPUT POWER S1 S2 P1 P2 L1 L2 L3 S1 S2 P1 P2 S1 S2 S1 S2 S1 S2 A B T 10 11 12 17 18 19 20 U1 U2 U3 N I1 I2 I3 RS 485 AUX AUX V...

Reviews: