background image

 

USER MANUAL 

 

 

 

EAP300PM2.5HC

 

 

Thank you for choosing electriQ 

Please read this user manual before using this innovative  

Air Purifier and keep it safe for future reference. 

 

Visit our page www.electriQ.co.uk for our entire range of Intelligent Electricals

 

Summary of Contents for 1489772

Page 1: ...HC Thank you for choosing electriQ Please read this user manual before using this innovative Air Purifier and keep it safe for future reference Visit our page www electriQ co uk for our entire range of Intelligent Electricals ...

Page 2: ...INSTRUCTIONS 8 BEFORE FIRST USE 8 CONTROL PANEL 9 FRONT DISPLAY 10 CARE AND MAINTENANCE 11 CLEANING THE PRE_FILTER AND FILTER HOLDING AREA 11 CHANGING THE FILTERS 11 CLEANING THE AIR QUALITY SENSOR 12 CLEANING THE CASE 12 CLEANING THE FILTER COVER AND CLEAN AIR OUTLET 12 TECHNICAL SPECIFICATION 13 TROUBLESHOOTING 13 SUPPORT 14 ...

Page 3: ... by those with a lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Do not leave children unsupervised with this device Do not clean the unit by spraying it or immersing it in water Use a damp cloth only Never allow water or vapours to enter the unit Do not clean with strong chemical a...

Page 4: ... injury Ensure hands are fully dried before plugging or unplugging the appliance The appliance should not be installed in laundry or wet rooms Always ensure the filters are fitted before turning on the appliance Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills For maximum performance and safety the minimum distance from a wall or ob...

Page 5: ...5 AIR PURIFIER DIAGRAM Air Outlet Air Quality Indicator Air Inlet Handle Air Quality Sensor Back Cover Power Cord Ambient Light Sensor Activated Carbon Filter HEPA Filter Pre Filter Air Inlet Panel ...

Page 6: ...rmaldehydes and benzenes The EAP300PM2 5HC also features a PM2 5 air quality sensor and a front facing display The display provides information on the air quality temperature and humidity of the air within the room APPLICATIONS Personal use in domestic and office space to improve air quality Helps smokers to reduce contaminants within the air Can help improve the symptoms of asthma and pollen alle...

Page 7: ...nclude bacteria viruses dust mites and pollen Emissions from electronic office equipment Many studies including those from EPA and the University of California Berkley have reported that emissions from office equipment such as computers and printers include VOCs ultra fine particles and ozone These emissions have been proven to have a negative effect on the health of many people which can be reduc...

Page 8: ... freed from the slots holding it in position then the HEPA and Carbon filter will slide out 3 Remove the filters from the plastic protective packaging 4 Load the filters into the rear of the unit ensuring the tags for removal are facing outwards The pre filter should be gently manipulated to ensure it is located into the slots in the unit 5 Reinstall the air inlet panel by locating the base of the...

Page 9: ... 3 hours To turn off the timer repeatedly press the timer button until all the indicator lights go out MODE Press to change between operating modes STANDARD Unit operates with the settings selected AUTO The fan speed will automatically adjust based on the air quality SILENT The fan will operate at low speed DISPLAY LOCK Press to turn the front display on and off Press and hold for 5 seconds to loc...

Page 10: ...owing the air quality on the screen The front indicator will alternate between showing the air quality humidity and temperature The display also illuminates to show a visual representation of the air quality INDICATOR COLOUR AIR QUALITY PM INDEX Blue Excellent 0 50 µg m3 Green Good 51 100 µg m3 Purple Medium 101 150 µg m3 Red Bad 151 µg m3 ...

Page 11: ...debris which has accumulated on it while cleaning the pre filter the filter holding area should also be wiped with a dry cloth If used in dustier environments the pre filter may require more regular cleaning For a deeper clean the pre filter can be removed and rinsed in clean water and then left to dry naturally Ensure the pre filter is fully dry before reinserting into the unit The pre filter mus...

Page 12: ...ain unit Avoid wetting the power connection port doing so may cause an electric shock and can lead to the insulation deteriorating or unit to rust CLEANING THE FILTER COVER AND CLEAN AIR OUTLET Use water and a mild detergent Do not use bleach or abrasives Do not spray water inside the unit If the clean air outlet grilles get soiled easily use a vacuum attachment or soft brush to clean If the filte...

Page 13: ...unit is plugged in Ensure that the filters and filter cover are correctly installed Abnormal Smells Check if the filters are clean Replace the filters Pollutants not removed and loud noise when running Check if the filters are clean Replace the filters Abnormally high Air Quality PM2 5 reading for prolonged period Clean the sensor Reset indicator flashing Replace the filters and reset the applianc...

Page 14: ...unsorted waste Collection of such waste must be handled separately as special treatment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to participating sites run by their local councils Please remember that this equipment will be further handled during the recycl...

Reviews: