background image

Installation manual

Tumble dryer

TD6–10

Compass Pro

Type N1190..

Original instructions

438917562/EN

2022.09.12

Summary of Contents for Compass Pro TD6-10

Page 1: ...Installation manual Tumble dryer TD6 10 Compass Pro Type N1190 Original instructions 438917562 EN 2022 09 12 ...

Page 2: ......

Page 3: ...duct 21 6 4 Shared exhaust duct 21 6 5 Exhaust dimensioning 22 6 6 Adjusting the dryer not valid for machines with heat pump 22 7 Gas connection 23 7 1 Fasten the label 23 7 2 General 23 7 3 Gas installation 24 7 4 Table of pressure and adjustment 24 7 5 Test run 26 7 6 Converting instructions 26 7 7 Data label 28 8 Electrical connection 29 8 1 Electrical installation 29 8 2 Single phase connectio...

Page 4: ...Contents The manufacturer reserves the right to make changes to design and component specifications ...

Page 5: ...ust not be installed behind a lockable door a sliding door or a door with a hinge on the opposite side to that of the machine in such a way that a full opening of the machine is restricted If the machine has a lint trap this has to be cleaned frequently The lint must not be accumulated around the machine DO NOT MODIFY THIS APPLIANCE When performing service or replacing parts the power must be disc...

Page 6: ...to catch fire Piling stacking or storing oil affected items can prevent heat from escaping and so create a fire hazard If it is unavoidable that fabrics that contain vegetable or cooking oil or have been conta minated by hair care products be placed in a tumble dryer they should first be washed in hot water with extra detergent this will reduce but not eliminate the hazard Maximum mass of dry clot...

Page 7: ...on or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the ap pliance Cleaning and user maintenance shall not be made by children without supervision Additional requirements for other countries This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of...

Page 8: ...8 Installation manual 1 5 Symbols Caution Caution hot surface Caution high voltage Read the instructions before using the machine ...

Page 9: ...es and or other that does not comply with the technical requirements for each appliance plumbing parts components or consumable cleaning products that are not approved by the manufacturer customer s negligence misuse abuse and or non compliance with the use and care instructions detailed within the appropriate equipment documentation improper or poor installation repair maintenance including tampe...

Page 10: ...ing C A 1 2 D B B a B c 3 E F G H 4 5 J I B b fig W00896A 1 Operating panel 2 Door opening 400 mm 3 Electrical connection 4 Gas connection 5 Exhaust connection A B B a B b B c C mm 720 805 765 750 695 1115 D E F G mm 405 45 180 90 H I J mm 115 80 560 ...

Page 11: ...on Electric heating 6 kW m3 h 270 Air consumption Electric heating 8 kW m3 h 290 Air consumption Gas heating 6 kW m3 h 270 Air consumption Gas heating 8 kW m3 h 290 Pressure drop Electric heating 6 kW Max Pa 380 Pressure drop Electric heating 8 kW Max Pa 350 Pressure drop Gas heating 6 kW Max Pa 380 Pressure drop Gas heating 8 kW Max Pa 350 A weighted emission sound pressure level at working stati...

Page 12: ...C B D E 3 F 4 5 G I H K J L M N O 6 fig 8005A 1 Operating panel 2 Door opening 400 mm 3 Electrical connection 4 Drain condensed water 5 Drain cooling water 6 Water connection A B C D E F mm 720 775 1685 1410 1505 45 G H I J K L mm 110 90 50 95 340 720 M N O mm 775 690 610 ...

Page 13: ...rding to ISO 60704 For assistance with dimensioning necessary ventilation needs contact authorized ventilation technician For suffi cient ventilation all sources introducing heat need to be taken into account plus all other parameters effecting the ventilation need Climate zone building parameters room size etc Heat pump Weight net kg 52 Pipe connection condensed water mm 19 Pipe connection drain ...

Page 14: ...pump unit and the tumble dryer are delivered as one unit The machine is delivered complete with supporting feet The machine is delivered bolted onto the transport pallet and packed in a crate or box Remove packing from the machine Remove the screws and the two brackets between the machine and pallet fig W00599 Remove the machine from the pallet Note When moving the machine handle it with care The ...

Page 15: ...struction for packaging 4 5 6 3 1 2 fig X02405 Fig Description Code Type 1 Wrapping film LDPE 4 Plastics 2 Corner protection PS 6 Plastics 3 Cardboard packaging PAP 20 Paper 4 Pallet FOR 50 Wood 5 Cable Tie Nylon 6 Plastic bag PET 1 Plastics ...

Page 16: ...enough space for working both for the user and service personnel Respecting the given recommendations will provide easy access for maintenance and service operations In case of space limitations it is possible to install machines without respecting to the given recommendations If so keep in mind that it might be necessary to disconnect and move other machines to be able to reach and perform servic...

Page 17: ...r intake connections to the machine should be fitted with manual shut off valves and filters to facilitate instal lation and servicing Water pipes and hoses should be flushed clean before installation The machine shall be connected with new water hoses Re used water hoses must not be used Hoses are to be of an approved type and grade and comply with IEC 61770 After installation hoses must hang in ...

Page 18: ...n manual 4 6 Mechanical installation Level the machine with the feet of the machine The maximum height adjustment of the feet is 50 mm If the machine is mounted on a base it needs to be fastened to the base fig 6321 ...

Page 19: ...oundation using four x M10 set screws Note The four fittings are not supplied with the machine and must be ordered as kit No 487193544 Fasten the machine to the fittings 675 mm 26 9 16 inch M10 M10 M10 M10 600 mm 23 5 8 inch 400 mm 15 3 4 inch M10 20Nm 512 mm 20 5 32 inch 585 mm 23 1 32 inch fig 6322 Note Marine installation is not applicable for gas heated machines ...

Page 20: ...ashers ironers radiators etc The combination of several sources for heat introduction leads to an increased need for ventilation flow Other factors may also influ ence the needed ventilation flow such as climate zone building parameters room size etc For assistance with di mensioning necessary ventilation needs contact authorized ventilation technician 6 2 Fresh air For maximum efficiency and the ...

Page 21: ...exhaust duct must have gentle bends 6 4 Shared exhaust duct It is recommended that each machine is connected to a separate exhaust duct When several machines shall use the same exhaust duct the exhaust duct must increase after each machine The recommended diameter increase progression is the one in the table If several machines are installed on the same exhaust pipe it is recommended to adjust the...

Page 22: ...time it will take to dry the load An air flow above the needed is unnecessary and can result in a cold laundry room and noise from the piping and out let and in extreme cases prolonged drying time For brief evacuations and where there are high airflows the tumble dryer must be adjusted to optimal flow One way in which this can be done is by using an Iris valve a valve specially designed to regulat...

Page 23: ... Art No GB IE Read the technical instructions before installing the appli ance Read the user instructions before lighting the appliance This appliance may only be installed in a room if the room meets the appropriate ventilation require ments specified in the national installation regulations Art No fig 7505 7 2 General May only be carried out by qualified personnel Mount a shut off valve upstream...

Page 24: ...a GR Greece SE Sweden HR Croatia SI Slovenia HU Hungary SK Slovakia IE Ireland TR Turkey You should check the kind of energy gas that is available in your place and check high altitude of the machine located place There are many gas types of the same kind but the machine should be equipped with different kinds of nozzles de pending on the gas type For non european countries check the heat value of...

Page 25: ...pressure mbar Injector pres sure mbar Injector size mm Air reducing plate mm Label number May be avail able in follow ing countries Butane mixture Propane mixture 3 28 30 37 No regulation 1 45 487042217 490375687 BE CH CY CZ ES FR GB GR IE IT LT LU LV PT SK SI Butane 3B P 30 37 50 28 1 45 487042217 490375688 BE CY DK EE FI FR GB HU IT LT NL NO SE SI SK RO HR TR BG IS LU MT PL AT CH DE SK Propane 3...

Page 26: ... turn connect a manometer to the measuring branch Select a program with heat Start the machine Check the nozzle pressure see Table of pressure and adjustment If necessary adjust the regulator setting screw 4 behind the cover screw 3 Replace the cover screw 3 if removed Check that the gas is burning evenly The blue flame on the burner is preferred 2 3 4 fig 7120 7 6 Converting instructions Disconne...

Page 27: ...er to the measuring branch Connect the power to the machine and select a program with heat Start the machine Set the correct nozzle pressure according to the table on setting screw 4 under the cover screw 3 2 3 4 fig 7120 Check that the gas flame burns evenly Mount the cover screw 3 Tighten the screw 2 when the adjustments are done Remount the back panel ...

Page 28: ...e Model Voltage Rated Input For safety reasons use only genuine spare parts Made in Sweden Electrolux Professional AB 341 80 Ljungby Sweden Product no Serial no Program OC Type WXXXXX 9868XXXXXX 09XXX 99XXXXX 09XXXXXX 10XX WN3 WN3XXXX 432XXXXXXXX 432XXXXXX 5XXX Product no Serial no Program OC Type Qn Hs 8 KW PIN NO 2575DM30490 AT BG CZ DK EE FI GR HR HU IS IE IT LV LT NO PT RO SK SI ES SE CH TR l2...

Page 29: ...nsure that the appropriate type of breaker is chosen and that the dimensioning is correct for maximum reliability connect only one machine per earth leakage circuit breaker it is important that the earth wire is properly connected In instances where the machine is not equipped with an omni polar switch one must be installed beforehand In accordance with the wiring rules mount a multi pole switch p...

Page 30: ...Brown Black L1 2NAC 380 415 The machine can also be con nected according to this figure N Blue Green Yellow Brown Black L1 L2 2AC 220 240 The machine can also be con nected according to this figure L2 Blue Green Yellow Brown Black L1 When the installation is completed remount the cover panel and check That the drum is empty That the machine operates by connecting the power to the machine and start...

Page 31: ...nit Connect the earth and other wires as shown 3AC L3 L2 L1 N 3AC L1 L2 L3 3NAC L3 L2 L1 N 3NAC N L1 L2 L3 When the installation is completed remount the cover panel and check That the drum is empty That the machine operates by connecting the power to the machine and start a program with heat ...

Page 32: ...y connecting the power to the machine and start a program with heat 8 4 Electrical connections Heating alternative Main voltage Hz Heating power kW Total power kW Recommended fuse A Electric heated 220 240V 1 1N 50 60 6 0 8 0 6 4 8 4 32 50 220 240V 3 50 60 6 0 8 0 6 4 8 4 20 25 380 415V 3N 3 50 60 6 0 8 0 6 4 8 4 10 16 440V 3 60 6 0 8 0 6 4 8 4 10 16 480V 3 60 6 0 8 0 6 4 8 4 10 16 115V 3 60 4 1 4...

Page 33: ...t system must transmit a start pulse 300 3000 ms 500 ms is recommended with a minimum pause of 300 ms 500 ms is recommended between two pulses The start pulse can be either 230V or 24V In order to receive a feedback signal once the machine has started 230V or 24V must be connected to connection 19 The feedback signal on connection 18 remains active high during the en tire program fig 7440 ...

Page 34: ...achine The signal must remain active high during drying When the signal gets inactive low the machine will abort ongoing program and enter cooling The signal can be either 230V or 24V In order to re ceive a feedback signal once the machine has started 230V or 24V must be connected to connection 19 The feed back signal remains active high during the entire program Program run fig 7439 ...

Page 35: ...5 3 External coin meter Central payment 2K The signal received from external coin meters must be a pulse between 300 3000 ms 500 ms is recommended with a minimum pause of 300 ms 500 ms is recommended between two pulses fig 7438 ...

Page 36: ...ed on time programs by the percent age entered in the price programming menu fig 7441 8 6 Option 8 6 1 External connection 100 mA A special connection terminal is located on the connection console This connection can be used as external control of a fan or a condensing unit 3AC The terminal for external control is equipped with 220 240V max 100 mA and is intended solely for the operation of a cont...

Page 37: ... in order to secure the panel on the back Mount the hinge A at the bottom of the opposite side Demount the door by carefully lifting it of the front Demount hinge B fig 7660 Demount the top panel Cut the cable tie and remove cable C to the opposite side Demount the plastic cover with door switch D and mount on the opposite side C D fig 7657 ...

Page 38: ...pposite side using the existing scews Mount the door by lifting it back on the fitting on the opposite side Mount the hinge B at the top B fig 7658 Demount the magnetic door lock E and magnet for switch F and mount on the opposite side F E fig 7659 Connect the power to the machine Test run the machine ...

Page 39: ...s This will be the language that all display messages program names etc will be presented in 10 2 Set time and date Select YES and press to get to the TIME DATE menu Activate the SET TIME menu and set the correct time Save the settings Activate the SET DATE menu and set the correct date Start by setting the year Set the year Exit to continue with a long press on Set the month Exit to continue with...

Page 40: ...d Check the direction of rotation only on machines with 3 phase power supply marine installation Demount the top panel and start a program Check that the drum rotation is clockwise fig 6311 If the direction is wrong swap two of the three phases to the left on the connection terminal fig 7119 Check the heat Let the machine work for five minutes on a program with heat Check that the heating is worki...

Page 41: ...cycled and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste but must be correctly disposed of in order to prevent any negative consequences for the environment and human health For further information on the recy cling of this product contact the local dealer o...

Page 42: ......

Page 43: ......

Page 44: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...

Reviews: