background image

Installation manual

Drying Cabinet

DC6-10HP

Original instructions

427001232/EN

2022.03.01

Summary of Contents for DC6-10HP

Page 1: ...Installation manual Drying Cabinet DC6 10HP Original instructions 427001232 EN 2022 03 01 ...

Page 2: ......

Page 3: ...e the doors 11 5 3 Remove the dehumidifier units 13 6 Positioning Attachment 16 6 1 Ventilate the room 16 6 2 Horizontal adjustment 16 6 3 Attachment to the wall 17 7 Connection to floor drain 18 8 Electrical connection 19 8 1 Alternative electrical connection 19 8 2 Connection to reservation system 20 9 Function check 21 10 Disposal information 22 10 1 Disposal of appliance at end of life 22 10 2...

Page 4: ......

Page 5: ...supervision or instruction con cerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Additional requirements for other countries This appliance is not intended for use by persons including children with reduced physical sensory or mental ca pabilities ...

Page 6: ... data 2 1 Dimensions drawing G H I J A F B E C D K 1 3 2 fig W01395 A B C D E F G H I J K mm 1395 652 1917 1931 14 1078 496 468 621 970 850 1 Control panel 2 Condensation nipple 10 mm hose 3 m included 3 Connecting cable 2 5 m included ...

Page 7: ...d Climate zone building parameters room size etc Connections Connection condensation Plastic hose dim 10 mm 3 m hose included Heat pump Type of refrigerant R407C Amount of refrigerant kg 1 0 Fluorinated greenhouse gases This product contains fluorinated greenhouse gases GWP 1430 CO2 equivalent 1 43 t Leak test 28 bar Hermetically sealed Energy consumption and drying times Drying of centrifuged lau...

Page 8: ...the MASTER were to stop working the drying cabinet will stop In such case it is possible to continue the process by reconfiguring the SLAVE to temporarily make it the MASTER This is described in more detail in the Service Manual It is not normally possible to perform heat pump servicing in the field If servicing is required the complete units must be removed and sent to Nimo Verken AB which has an...

Page 9: ...ct Packaging materials such as plastic and styrofoam should be kept out of reach of children 4 1 Installation kit 1 2 3 4 5 6 fig W01398 1 Screw T6S 6x75 galvanized for wall mounting 2 Screw M6S 8x16 for mounting bracket 3 Washer BRB 8 4x17x1 6 4 Wall plug 5 Mounting bracket for wall mounting 6 Brush for filter cleaning ...

Page 10: ...ying cabinet and thereby facilitate installation If all of the measures are implemented the weight of the drying cabinet will be cut almost in half Remove the hanger section Remove the doors Remove the dehumidifier units 5 1 Remove the hanger section Remove the hanger stop as illustrated Lift and unhook the section fig W01399 ...

Page 11: ...e and expose the door cable C Then detach the cable from the connector D Remove the upper hinge E which is secured with two screws Carefully pull the hinge loose from the cable The hinge has a slot where the cable can be threaded in or out Lift the door off of the drying cabinet E A E C D B fig W01400 A Hatch B Cover over the hinge C Door cable D Connector E Upper hinge ...

Page 12: ...allation manual Left door Remove the cover F from over the hinge Remove the hinge G which is secured with two screws Lift the door off of the drying cabinet F G fig W01401 F Cover over the hinge G Upper hinge ...

Page 13: ...nt plate A which is secured with two screws on the top under plastic plugs Unplug the electrical connection between the door switches and the left dehumidifier unit Then remove the front plate Detach the filters B and remove them A B fig W01402 A Front plate B Dirt filter ...

Page 14: ...he air deflector D This is secured with two plastic Torx 40 screws which are located under cover plugs E The air deflector can either be taken out or left in position Do not forget to reinstall the cover plugs when reassembling the cabinet Otherwise there will be air leakage resulting in reduced performance C D E fig W01403 C Hatch D Air deflector E Cover plugs ...

Page 15: ... Property s reservation system 2 Loose modular cable black 3 User interface control panel white cable 4 LED lighting 5 Door switch 6 Mains connection 7 MASTER 8 SLAVE Detach the condensation connection F from both units Remove the locking washer G and take out both of the dehumidifier units F G fig W01405 ...

Page 16: ... could for example be more tumble dryers drying cabinets washers ironers radiators etc The combination of several sources for heat introduction leads to an increased need for ventilation flow Other factors may also influ ence the needed ventilation flow such as climate zone building parameters room size etc For assistance with di mensioning necessary ventilation needs contact authorized ventilatio...

Page 17: ...ng The installation kit contains two angle brackets that are mounted on the upper part of the drying cabinet as illustrated Use the provided screws The brackets have grooves for adjustment to the wall Secure the cabinet to the wall The installation kit contains a fastening screw and plastic plugs fig W01407 ...

Page 18: ...wn towards the floor and forms a water trap If you fail to do this there is a risk of condensation flowing back to the box when the pump is not running This could cause the box to fill with water and the cabinet to stop working 2 1 3 fig W01409 1 Left side s drain hose 2 Right side s drain hose 3 Nipple Replace check the drain side by moving the nipple drain hose on either the right or the left si...

Page 19: ...and then press both program buttons ACCESS 0000 is shown in the display Enter the code 9191 Enter the numbers using the program buttons press Stop Use the program buttons to move to Parameter 117 and enter the parameter using the Stop button Set the parameter value to 1 This will activate the cabinet for network use Use the Stop button to exit the parameter To confirm the new settings Press the St...

Page 20: ...tion system for the laundry room the drying cabinet can be connected to this Connection is handled via an external electronics box that can be ordered from Electrolux Professional This is con nected to connector B on the Master unit 1 2 B fig W01411 B Master unit connector 1 MASTER 2 SLAVE ...

Page 21: ...henever a repair has been made a function check must be performed before the appliance can be used again Select any program and check that the drying cabinet is heating and that there are no odd noises Ready for use If all tests are OK the appliance is now ready for use If any of the tests fail or deficiencies or faults are detected please contact your local service organization or supplier ...

Page 22: ...cycled and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste but must be correctly disposed of in order to prevent any negative consequences for the environment and human health For further information on the recy cling of this product contact the local dealer o...