background image

Installation, Use & Care Guide

30” and 36” Free-Standing Range Hood

EI30 EI36WC55GS

316488524

Summary of Contents for 316488524

Page 1: ...Use Care Guide 30 and 36 Free Standing Range Hood Guia de Instalación Uso y Cuidado 30 y 36 Campana extractora Guide d installation utilisation et d entretien 30 et 36 Hotte aspirante EI30WC55GS EI36WC55GS 316488524 ...

Page 2: ... ements ements 5 5 5 5 5 Electrical requirements 5 Before installing the hood 5 List of Materials List of Materials List of Materials List of Materials List of Materials 6 6 6 6 6 Parts Included with your Hood 6 Optional Accessories 6 Tools Materials required 6 Installing the hood Installing the hood Installing the hood Installing the hood Installing the hood 7 13 7 13 7 13 7 13 7 13 Installing pr...

Page 3: ... For r For r For residential use only esidential use only esidential use only esidential use only esidential use only Do not attempt to install or operate your appliance until you have read the safety precautions in this manual Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type This symbol alerts you to situations that may cause serious body harm death...

Page 4: ...ll and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit OPERATION a Always leave safety grills and filters in place Without these components operating blowers could catch onto hair fingers and loose clothing The manufacturer declines all responsibility in the event of failure to observe the instructions given here for i...

Page 5: ...NFPA 70 latest edi tion or CSA Standards C22 1 94 Canadian Electri cal Code Part 1 and C22 2 No 0 M91 latest edi tion and all local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Q...

Page 6: ... pieces Optional Accessories Optional Accessories Optional Accessories Optional Accessories Optional Accessories Telescopic duct cover to fit ceiling height from 8 to 10 Re circulation KIT Charcoal Filter T T T T Tools Materials r ools Materials r ools Materials r ools Materials r ools Materials requir equir equir equir equired ed ed ed ed Duct tape Wire nuts Tape to mount template 8 rounded metal...

Page 7: ... installed for recirculating operation recirculating accessories not supplied with the hood This hood can be installed over any electric and gas cooktop range It can not be installed over any pr It can not be installed over any pr It can not be installed over any pr It can not be installed over any pr It can not be installed over any professional ofessional ofessional ofessional ofessional cooktop...

Page 8: ...uct fitting exists Limit use to short lengths and do not crush when making corners Ductwork and wiring locations Ductwork and wiring locations Ductwork and wiring locations Ductwork and wiring locations Ductwork and wiring locations Determine the exact location of the vent hood Locate the template packed with the literature Installation height 30 gas cooktop range or 24 to 30 electric cooktop rang...

Page 9: ...iling ducting Ceiling ducting Ceiling ducting If the duct will vent straight up to the ceiling Use level to draw a line straight up from the centerline on the template to the ceiling Measure at least 4 3 4 from the back wall to the circle center of an 8 hole on the ceiling W W W W Wall ducting all ducting all ducting all ducting all ducting If ductwork will vent to rear Use a level to draw a line ...

Page 10: ...t be capable of Framing must be capable of Framing must be capable of Framing must be capable of supporting 100 lbs supporting 100 lbs supporting 100 lbs supporting 100 lbs supporting 100 lbs 1 x6 Min Mounting Support Centerline of Installation Space View From Rear Cleats 8 1 2 min opening for ductwork Mounting the hood Mounting the hood Mounting the hood Mounting the hood Mounting the hood 2 peop...

Page 11: ...ct tape over seam Airflow Air deflector installation Air deflector installation Air deflector installation Air deflector installation Air deflector installation Recir Recir Recir Recir Recirculating accessories culating accessories culating accessories culating accessories culating accessories Assemble the air deflector with the duct cover bracket with 4 assembly screws provided as shown Measure f...

Page 12: ...CIRCUMSTANCES BE CUT OR REMO VED Failur Failur Failur Failur Failure to do so can r e to do so can r e to do so can r e to do so can r e to do so can result in death or electrical esult in death or electrical esult in death or electrical esult in death or electrical esult in death or electrical shock shock shock shock shock Remove junction box cover and knockout on the top left side Knockout Junct...

Page 13: ...per part of the telescopic duct cover pull it and place it in the duct cover mounting bracket Secure the top of the duct with 2 assembly screws provided Secure the bottom of the duct with 2 assembly screws provided Instal the grease filter and turn power on at service panel Check operation of the hood IMPORTANT If the hood doesn t switch ON before calling for service check if the internal General ...

Page 14: ... 1 1 1 Blower and light controls 2 2 2 2 2 Lamp housings 3 3 3 3 3 Grease filter Handle 4 4 4 4 4 Grease filter 5 5 5 5 5 Canopy 6 6 6 6 6 Duct covers 7 7 7 7 7 Louver holes Only for Recirculating version 1 7 6 5 4 3 2 2 Features ...

Page 15: ... following drawing are described the main key functions 1 2 3 4 5 1 Light Button 1 Light Button 1 Light Button 1 Light Button 1 Light Button Press lamp button to turn ON the light Lamp state previously OFF Press lamp button to turn OFF the light Lamp state previously ON 2 Timer Button 2 Timer Button 2 Timer Button 2 Timer Button 2 Timer Button The default timer setting is 10 minutes and it can be ...

Page 16: ...es on display the charcoal filters installed are required to be replaced or reactivated To reset the charcoal filter saturation indication the user must press the button for 5 seconds after this time the icon Char Char Char Char Charcoal filter coal filter coal filter coal filter coal filter is not displayed and the hood has the normal display operation Audible signal activation and deactivation A...

Page 17: ...lish air currents upward through the hood Thus when heat smoke moisture grease and cooking odors are produced they will be carried outside instead of drifting into other rooms Use the low speeds for normal use and the higher speeds for strong odors or fumes Drafts across the range or cooktop will cause the escape of heat smoke moisture grease and cooking odors from the hood Such drafts should be p...

Page 18: ...t power from being switched on accidentally NOTE T NOTE T NOTE T NOTE T NOTE Tur ur ur ur urn of n of n of n of n off the lights and fan Allow the lights f the lights and fan Allow the lights f the lights and fan Allow the lights f the lights and fan Allow the lights f the lights and fan Allow the lights to to to to to cool cool cool cool cool befor befor befor befor before handling e handling e h...

Page 19: ...nless steel finishes in the direction of the grain Wipe area dry to avoid water marks After cleaning place all parts in their proper positions before using The cleaners recommended below indicate a type and do not constitute an endorsement Use all products according to package directions Hood Surface Hood Surface Hood Surface Hood Surface Hood Surface Painted Surfaces Painted Surfaces Painted Surf...

Page 20: ...onnections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent tubes on models with these features This warranty does not cover the following This warranty ...

Reviews: