background image

Summary of Contents for CGBM185KBC

Page 1: ...from cooking surface i i i i i Figure 1 66 or more from floor 2 WALLCONSTRUCTION This Over the Range Microwave Oven should be mounted against and supported by a flat vertical wall The wall must be flat for proper installation If the wall is not flat use spacers to fill in the gaps Wall construction should be a minimum of 2 x 4 wood studding and 3 8 or more thick dry wall or plaster lath The mounti...

Page 2: ...edures When the hood is vented to the outside a hood exhaust duct is required All ductwork must be metal absolutely do not use plastic duct Check that all connections are made securely Please read the following carefully EXHAUSTCONNECTION The hood exhaust has been designed to connect to a standard 3 V4 x 10 rectangular duct If round duct is required a rectangular to round adapter must be used REAR...

Page 3: ...avity SAVE THE CARTON AS IT MAY MAKE INSTALLATION EASIER 2 CHECK THE OVEN Check the oven for any damage such as misaligned or bent door damaged door seals and sealing surfaces broken or loose door hinges and latches and dents inside the cavity or on the door If there is any damage do not operate the oven and contact your dealer or Electrolux AUTHORIZED SERVICER 6 INSTALLATION HARDWARE The INSTALLA...

Page 4: ...to attach Exhaust Damper Assembly to the wall later and discard remaining 5 Remove Fan Cover Bracket by sliding it in the opposite direction of the arrow on the Fan Cover Bracket as shown in Figure 7 Lift Hood Fan Unit carefully and slip wires out of cavity See Figure 8 CAUTION Do net pull or stretch Hood Fan Wire 3 Rotate the Hood Fan Unit 180 so that the Fan Blade Openings are facing the back of...

Page 5: ...et and the Hood Fan Unit Put the lead wire into Wire Box 4 Replace the Fan Cover Bracket by sliding it into the slits in the same direction as the arrow on the Fan Cover Bracket Make sure the fan blades are visible through the top openings in the oven before proceeding See Figure 14 on page 6 5 Attach the Fan Cover Bracket to unit with the 3 screws from back edge and 4 screws except screw A from t...

Page 6: ...Bolts through the holes in the wall with the Toggle Nuts closed See Figure 16 Use Wood Screws to attach the Mounting Plate to studs NOTE Before insertion be sure you leave a space more than the thickness of the wall between the Mounting Plate and the end of each of the Toggle Nuts in the closed position If you do not leave enough space the Toggle Nut will not be able to open on the other side of t...

Page 7: ...apping Screws 4 x 8 mm from the INSTALLATION HARDWARE See Figure 19 on page 7 5 For Vertical Exhaust Only Attach the Exhaust Damper Assembly to the fan Cover Bracket on the top of the outercase cabinet by sliding it into the slits in the same direction as the allow using screw A which removed at C VERTICAL EXHAUST STEP 1 on page 5 See Figure 20 on page 7 Tabs Figure 18 Tapping Screw A J Figure 20 ...

Page 8: ......

Page 9: ...76 cm au moJnsde Aurnoins 2 pc 5 1cm la surfacede cuisson 66 po 167 6cm ch6ma 1 2 CONSTRUCTION DU IVlUR Le four a micro ondes a hotte integr6e doit _tre supporte par un mur vertical plat Pour une installation correcte lemur doit _tre plat Si ce n est pas le cas employez des entretoises pour remplir les espaces La construction du mur dolt avoir des poteaux muraux de 2 x 4 pc et une cloison sbche ou...

Page 10: ...un conduit d evacuation b la hotte Tousles conduits doivent _tre en metal n employez aucun conduit en plastique Verifiez que toutes les connexions sont bien settees Veuillez life attentivement ce qui suit CONNEXION DEL EVACUATION I evacuation de la hotte est congue pour _tre connectee un conduit rectangulaire standard de 31 4 x 10 po 8 3 cm x 25 4 cm Si vous avez besoin d un conduit circulaire il ...

Page 11: ...lafond 316902447 Gabarit pour lemur 316902448 1 Ouvrez le fond du carton basculez les rabats en artiste et basculez le four pour le deposer sur la cale en mousse plastique Otez le carton et sortez tousles emballages de protection les Instructions d installation le gabarit mural le gabarit de plafond le plateau toumant et son support Cependant N ENLEVEZ PAS LE CACHE DU GUIDE D ONDES qui est situe s...

Page 12: ...r et jetez les 5 autres Enlevez cette piece en la glissant dans la direction oppos6e b la fieche marquee dessus comme illustre sur le Schema 7 Levez I unite de ventilation de hotte avec precaution et glissez les ills hors de la cavite voir le Schema 8 ATTENTION NE TIBEZ PAS SUB LES FILS DE CABLAGEET NE LES I_TIBEZPAS 3 FaRes pivoter I unite de ventilation de la hotte de 180 de fagon b ce que les o...

Page 13: ...ite pivoter le ventilateur de hotte de 90 de fa on Ace que les ouvertures des pales du ventilateur soient orient6es vers le haut du four Voir le schema 13 page 6 Remplacez le ventilateur dans le four Faites attention A ne pas pincer le fil de fil entre la fixation int6rieure et I unite de ventilation Placez le fil de connexion dans la botte de raccordement 4 Remettez en place la fixation du couver...

Page 14: ...rous dans le mur les ailettes refermees Voir le schema 16 Employez les vis a bois pour fixer la plaque de fixation aux poteaux muraux REMARQUE Avant d inserer les boulons veillez a laisser un espace sup6rieur a I epaisseur du mur entre la plaque de fixation et I extremit6 des ecrous ailettes en position ferm_e Si vous ne laissez pas assez d espace I ecrou a ailettes ne pourra pas s ouvrir de I aut...

Page 15: ...le schema 19 page 7 5 Uniquement pour I echappement vertical Fixer le systeme de mouillage de I echappement sur le support du couvercle du ventilateur qui se trouve au dessus du coffret le plus I exterieur en le glissant dans les fentes en suivant la direction de la fleche et en se servant de la vis A enlevee en C ECHAPPEMENT VERTICAL TAPE 1 b la page 5 Voir Schema 20 b la page 7 Vis Autotaraudeus...

Page 16: ......

Page 17: ...a la superficie de lacocina 66 o m_s con respecto al piso 2 COHSTRUCCII N DEPARED Este Homo microondas sobre estufa debe montarse y apoyarse en una pared vertical plana La pared debe ser plana para una instalaci6n apropiada Si la pared no es plana utilice espaciadores para Ilenar los vacios La construcci6n de pared debe consistir de montantes de madera de 2 x 4 como minimo y tablaroca o yeso list6...

Page 18: ...e un ducto de escape de campana Todo el ducto debe ser metalico categ6ricamente no utilice ducto plastico Verifique que todas las conexiones est_ n sujetadas firmemente Por favor lea cuidadosamente Io siguiente CONEXION DE ESCAPE El escape de la campana ha sido diseSado para conectarse con un ducto rectangular est_ ndar de 3 W x 10 Si se requiere ducto redondo debe utilizarse un adaptador de recta...

Page 19: ...i6n 316902446 Plantilla superior 316902447 Plantilla de pared 316902448 _1_ _ k2_ _i Utilice con gabJnetes metalicoe _5_ _ i Bordee el orJficio para el cable de i_ energia Corte para ajustar _ _ s h 7 PREPARACION DELHORNO 1 2 Abra la parte inferior de la caja de cart6n doble hacia atras las alas de la caja de cart6n y voltee la caja para colocar el homo sobre el cojin de espuma plastica Levante y ...

Page 20: ...lo en la direcci6n contraria de la flecha que aparece en el soporte como se muestra en la Figura 7 Levante la unidad de ventilador de la campana extractora y deslice los alambres afuera de la cavidad Vea la Figura 8 Precauci6n No jale o estire los Alambres del Ventilador de la Campana Gire la unidad de ventilador de la campana 180 para que los Orificios de las Paletas del Ventilador est_n frente a...

Page 21: ...dad de ventilador de la campana Coloque el conductor en la caja de alambres 4 Coloque nuevamente el soporte de la cubierta del ventilador deslizandolo porlas ranurasen lamismadirecci6n delaflechadela cubiertadelventilador Aseg_ resedequelas paletasdelventilador sean visibles a traves de los orificios superiores en el homo antes de preceder Vea la Figura 14 de la pb gina 6 5 Fije el soporte de la c...

Page 22: ...os corresponden a Jos orificios de Ja pJantiJJa de pared y coloque Jas tuercas de anclaje sobre los pernos de anclaje Vea la Figura 15 Consulte Jas instrucciones de Ja pJantiJJa de pared 3 4 D B Coloque la Placa de Montaje con los Pernos de Anclaje sujetados en el sitio de pared e inserte los Pernos y Tuercas de Anclaje a trav6s de los orificios en la pared con las Tuercas de Anclaje cerradas Vea ...

Page 23: ... de la p_ gina 7 5 Solo para escape vertical Conecte el regulador de succi6n de extracci6n al soporte de la cubierta del ventilador en la parte superior del homo al deslizarlo en las ranuras en la misma direcci6n que marca la Leng_ietas Figura 18 Tornillos Gabinete Superior _ Arandelas Planas j TorniJlo Auto perforante A Figura 20 flecha hasta que el tornillo A que se retir6 en C ESCAPE VERTICAL P...

Page 24: ......

Reviews: