Installation 

Over the Range

Instructions

Microwave Oven

Read these instructions completely and carefully.

IMPORTANT –

Save these 

instructions for local inspector’s use.

IMPORTANT –

Observe all 

governing codes and ordinances.

Note to Installer –

Be sure to leave these

instructions with the Consumer.

BEFORE YOU BEGIN

Note to Consumer –

Keep these 

instructions for future reference.

Skill level

– Installation of this appliance requires

basic mechanical and electrical skills.

Proper installation is the responsibility of the installer. 

Product failure due to improper installation is not
covered under the Warranty.

1-877-435-3287(US)

Questions? Call

1-800-265-8352(Canada)

p/n 316902904

April 2012

http://www.electroluxappliances.com  

:

Summary of Contents for EI30BM60M

Page 1: ...to Installer Be sure to leave these instructions with the Consumer BEFORE YOU BEGIN Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical and electrical skills Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty 1 877 435 3287 US Questio...

Page 2: ... B C Installation Instructions 21 20 20 Recirculating Mount the Microwave Oven 19 Preparation of Top Cabinet 17 Attach Mounting Plate to Wall 17 Outside Back Exhaust 16 Connecting Ductwork 15 Adjust the Exhaust Adaptor 15 Operation 14 Outside Back Exhaust 16 19 Adapting Microwave Blower for Outside top Exhaust 13 14 Placement of The Mounting Plate 12 15 Preparing Rear Wall for Remove Blower Plate ...

Page 3: ...CK The power cord of this appliance is equipped with a three prong grounding plug which mates with a standard three prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance You should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded Where a standard two prong wall receptacle is e...

Page 4: ... customer repair or replacement must be made by arrangement between customer and installer DAMAGE SHIPMENT INSTALLATION Installation Instructions PARTS INCLUDED You will find the installation hardware contained in a packet with the unit Check to make sure you have all these parts NOTE Some extra parts are included HARDWARE PACKET PART QUANTITY Template 1 Template Installation 1 Instructions Separa...

Page 5: ...een the cabinets must be 30 76 2 cm wide and free of obstructions If you are going to vent your microwave oven to the outside see Hood Exhaust Section for exhaust duct preparation When installing the microwave oven beneath smooth flat cabinets be careful to follow the instructions on the top cabinet template for power cord clearance Bottom Edge of Cabinet Needs to be 30 76 2 cm or More from the Co...

Page 6: ...he installation instructions filters glass Fold back all 4 carton flaps fully against carton sides Then carefully roll the oven and carton over onto the top side The oven should be resting in the Styrofoam REMOVING THE MICROWAVE OVEN FROM THE CARTON REMOVING THE MOUNTING PLATE FINDING THE WALL STUDS B A 2 PLACEMENT OF THE MOUNTING PLATE 1 Wall Studs Center 3 Carton Pull the carton up and off the o...

Page 7: ...is important to use at least one wood screw mounted firmly in a stud to support the weight of the microwave Mark two additional evenly spaced locations for the supplied toggle bolts 3 Drill holes in the marked locations Where there is a stud drill a 3 16 hole for wood screws For holes that do not line up with a stud drill 5 8 holes for toggle bolts DO NOT INSTALL THE MOUNTING PLATE AT THIS TIME 4 ...

Page 8: ... the rear wall 5 Review the Installation Instruction book for your installation situation Locate and mark holes to align with holes in the mounting plate IMPORTANT LOCATE AT LEAST ONE STUD ON EITHER SIDE OF THE CENTERLINE MARK THE LOCATION FOR 2 ADDITIONAL EVENLY SPACED TOGGLE BOLTS IN THE MOUNTING PLATE AREA Locate and mark holes to align with holes in the mounting plate IMPORTANT LOCATE AT LEAST...

Page 9: ...ACK EXHAUST HORIZONTAL DUCT RECIRCULATING NON VENTED DUCTLESS See page 12 On modelsshipped for recirculating exhaust a disposable charcoal filter isfactory installed to help remove smoke and odors Adaptor inP lacefor O utsideT opE xhaust Installation Instructions 2 B C Adaptor Must Be MovedtotheBackfor O utsideBackE xhaust NOTE Thismicrowave isshipped assembled for Recirculating Select the type of...

Page 10: ...es clear venting of exhaust and helps prevent blockages Also make sure dampers swing freely and nothing is blocking the ducts Exhaust connection The exhaust adaptor has been designed to mate with a standard 31 4 x 10 8 2 x 25 4 cm rectangular duct If a round duct is required a rectangular to round transition adaptor must be used Maximum duct length For satisfactory air movement the total duct leng...

Page 11: ...aken to align exhaust with space between studs or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust IMPORTANT If a rectangular to round transition adaptor is used the bottom corners of the damper will have to be cut to fit using the tin snips in order to allow free movement of the damper The following chart describes an exam...

Page 12: ...ed A7 Connect Ductwork A3 A4 Check Damper Operation Adapting Microwave Blower for Outside Top Exhaust 3 8 TO EDGE NOTE IT IS VERY IMPORTANT TO READ AND FOLLOW THE DIRECTIONS IN THE INSTALLATION INSTRUCTIONS BEFORE PROCEEDING WITH THIS REAR WALL TEMPLATE This Rear Wall Template serves to position the bottom mounting plate and to locate the horizontal exhaust outlet 1 Use a level to check that the t...

Page 13: ...crew holding the blower motor to the microwave Blower Plate Blower Motor Screw Back of Microwave 2 End B End A Carefully pull out the blower unit The wires will extend far enough to allow you to adjust the blower unit 1 ADAPTING MICROWAVE BLOWER FOR OUTSIDE TOP EXHAUST Roll the blower unit 90 so that fan blade microwave 3 Back of Microwave Before Rotation After Rotation Back of Microwave Back of M...

Page 14: ...hrough hole in bottom of top cabinet Keep it tight throughout Steps 1 3 Do not pinch cord or lift oven by pulling cord Lift microwave tilt it forward and hook slots at back bottom edge onto four lower tabs of mounting plate 1 CHECK FOR PROPER DAMPER OPERATION Exhaust Adaptor Blower Plate Damper Back of Microwave Make sure tape securing damper is removed and damper pivots easily before mounting mic...

Page 15: ...rew Install grease filters See the Owner s Manual packed with the microwave Installation Instructions ADJUST THE EXHAUST ADAPTOR Open the top cabinet and adjust the exhaust adaptor to connect to the house duct Back of Microwave For Front to Back or Side to Side Adjustment Slide the Exhaust Adaptor as Needed Blower Plate Damper Self Aligning Screw 5 MOUNT THE MICROWAVE OVEN cont A6 A5 CONNECTING DU...

Page 16: ...AST ONE STUD ON EITHER SIDE OF THE CENTER LINE MARK THE LOCATI ON FOR 2 ADDITIO NAL EVENLY SPACED TOGGL E BOLTS IN THE MOUNT ING PLATE AREA Locate and mark holes to align with holes in the mountin g plate IMPORT ANT LOCATE AT LEAST ONE STUD ON EITHER SIDE OF THE CENTER LINE MARK THE LOCATI ON FOR 2 ADDITIO NAL EVENLY SPACED TOGGL E BOLTS IN THE MOUNT ING PLATE AREA Trim the rear wall templat e alo...

Page 17: ...mounting plate through the holes designated to go into drywall and reattach the toggle wings to 3 4 19 mm onto each bolt 1 2 Place the mounting plate against the wall and insert the toggle wings into the holes in the wall to mount the plate NOTE Before tightening toggle bolts and wood screw make sure the tabs on the mounting plate touch the bottom of the cabinet when pushed flush against the wall ...

Page 18: ...g Wires Routed Through Right Side Wires Routed Through Left Side Back of Microwave Back of Microwave Blower Plate Blower Motor Screw Secure the blower unit to the microwave with the original screw Before Rolling After Rolling Back of Microwave End A End B Back of Microwave Back of Microwave CAUTION Do not pull or stretch the blower unit wiring Make sure the wires are not pinched and that they are ...

Page 19: ... later Be sure to keep power cord tight Be careful not to pinch the cord especially when mounting flush to bottom of cabinet 8 7 5 Cabinet Front Cabinet Bottom Shelf Tighten the outer two screws to the top of the microwave oven While tightening screws hold the microwave oven in place against the wall and the top cabinet Filler Block Microwave Oven Top Equivalent to Depth of Cabinet Recess Insert 2...

Page 20: ...eattach the toggle wings to 3 4 19 mm onto each bolt 1 Wall Mounting Plate Spacing for Toggles More Than Wall Thickness Bolt End Toggle Bolt Toggle Wings To use toggle bolts 2 RECIRCULATING Non Vented Ductless C Install or change Charcoal Filter C3 Check Blower Plate 3 8 TO EDGE NOTE IT IS VERY IMPORTANT TO READ AND FOLLOW THE DIRECTIONS IN THE INSTALLATION INSTRUCTIONS BEFORE PROCEEDING WITH THIS...

Page 21: ...rt a self aligning screw through top center cabinet hole Temporarily secure the oven by turning the screw at least two full turns after the threads have engaged It will be completely tightened later Be sure to keep power cord tight Be careful not to pinch the cord especially when mounting flush to bottom of cabinet Self Aligning Screw 4 2 Rotate front of oven up against cabinet bottom NOTE When mo...

Page 22: ...ave C4 3 2 1 1 Phillipsscrewdriver Open the door Remove the grille Pull the grille straight off NOTE The charcoal filter isfactory installed in recirculating models Follow these stepsto replace a filter or to install a filter after converting a vented model to recirculating operation Remove screwson top of grille using a C5 INSTALLING OR CHANGE THE CHARCOAL FILTER 6 4 Replace the grille and the sc...

Page 23: ...n has been installed according to instructions 1 BEFORE YOU USE YOUR MICROWAVE Ensure proper ground exists before use INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MANUAL 3 USE CARE FILL OUT PRODUCT REGISTRATION CARD 8 D G DDDDDDD PRODUCT CARD Read the Manual Installation Instructions ring and glass tray in cavity Install turntable REGISTRATION USE CARE Replace house fuse or turn breaker bac...

Page 24: ... a stud drill 5 8 holes for toggle bolts DO NOT INSTALL THE MOUNTING PLATE AT THIS TIME 4 Remove the template from the rear wall 5 Review the Installation Instruction book for your installation situation Locate and mark holes to align with holes in the mounting plate IMPORTANT LOCATE AT LEAST ONE STUD ON EITHER SIDE OF THE CENTERLINE MARK THE LOCATION FOR 2 ADDITIONAL EVENLY SPACED TOGGLE BOLTS IN...

Reviews: