Instruction Manual
R2 AT A GLANCE
BACK CARE SOLUTION
Dynamic Stretching
Vibration Massage
Thermal Therapy
Electrical Muscle Stimulation
1) Electromagnetic chip
2) Vibrator
3) Heating film
4) Air traction system
5) Control wire
6) Control panel
7) Base plate
OPERATING
1) Press auto mode button to turn on the device. Press and hold the button again to turn
off.
2) Press the auto mode button to switch between four different auto modes: 01: vibration
+ air inflaction, 02: heat + vib air inflaction, 03: automatic air inflaction, 04: heat
+ air inflaction
3) Press stretch control button, vibration control button, or heating control button to turn
on three different functions separately. The auto mode will stop.
4) Press stetch control button, the waist will be lifted automatically to start dynamic
streching. Press the button again once comfortable height is reached. A n alarm will
sound once you have reached maximum lift. Press and hold the button to release the
pressure. The rating bar will blink when releasing and stop blinking when it reaches the
original position.
5) Press vibration control button to turn on the vibration massage, press and hold the
button to turn off. Press the vibration control button to switch the strength between
low, medium, and high.
6) Press the heating control button to turn on the thermal therapy, press and hold the
button to turn off. Press the heating control button to switch the heat between low,
medium, and high. The rating bar will blink when reaching the maximum temperature.
7) Press the electrical muscle stimulator button to turn on EMS, press and hold the button
to turn off. Press the electrical muscle stimulator button to switch between different
types of EMS massage. Press the EMS plus button to increase the massage strength, and
press the EMS minus button to decrease. The level of the strength will be presented in
the touch screen controller. 20 is the highest level.
8) To insert an external connector into the electrical pulse output, attach the pads to the
corresponding location you would like to massage (arms, legs etc.).
9) Reattach pulse pads to protective paper after used.
SAFETY INSTRUCTIONS
1) Only use the adapter that was supplied with the device.
2) Do not let the device fall from high place, and do not keep it around sharp objects.
3) Do not use this product when you are sleeping.
4) Do not use other medical electronic devices at the same time, such as pacemakers,
heart-lung machines or electrocardiographs. If the patient is simultaneously using high
frequency surgical equipment or other related equipment, the electrical pulse patches in
the device may cause burns or damage the equipment. If the equipment is used near a
microwave, the output of the device may become unstable.
5) Keep away from children.
6) When using the electric pulse function, do not move or change the position.
DISCLAIMER
Please do not use the ELEEELS R2 without first obtaining approval from your doctor if any of
the following apply: pregnant, have skin sensitivities, heart disease, blood pressure
abnormalities, malignant tumors, cerebrovascular diseases, diabetes, recent joint replace-
ments, metal pins or plates or you have any concerns about your physical health. Do not
use R1 if you feel pain, discomfort, or have a wound at or near the site of application.
WARRANTY
IF WITHIN ONE YEAR FROM THE DATE OF PURCHASE, THIS PRODUCT FAILS DUE TO A
DEFECT IN MATERIAL OR WORKMANSHIP, ELEEELS WILL REPAIR OR REPLACE THE PRODUCT,
OR NECESSARY COMPONENTS, FREE OF CHARGE
THIS WARRANTY EXCLUDES:
(a) damage caused by accident, abuse, mishandling, or transport;
(b) units subjected to unauthorized repair;
(c) units not used in accordance with ELEEELS care instructions;
(d) damage exceeding the cost of the product;
(e) deterioration of the delivered product resulting from abnormal storage and/or
safeguarding conditions on the client's premises, and
(f) failure to show the dated proof of purchase
Display Screen
Auto Mode Button
Vibration Control Button
Heating Control Button
Stretch Control Button
Electrical Muscle
Stimulator Button
USE OF SILICON ELECTRODE SLICES
- Insert one end of the 2-core connector wires into the electrode port and connect the
other end to the electrode slices.
- The electrode slices should be clean on their surfaces without any dust, oily or sticky
substance. If their surfaces become dirty, flush with clean water and then air dry them
before repeated use.
- The electrode slices can be used for around 50 times of 20 minutes session. If their
viscosity cannot be recovered after several times of cleaning, please replace new ones.
- Only use the electrode slices provided with the device.
- Please dispose electrode slices according to your local environmental regulations rather
than discarding them at will.
NOTE: It is recommended to use the EMS massager once or twice a day. Please
give your skin a break from the electrode pads in every 20 minutes. Leaving pads on the
same skin location may cause skin irritation.
MAINTENANCE, CLEANING & STORAGE
- Store this device in a moisture-free, dry place when not in use.
- Do not wrap the power cord around the device.
- Do not use the power cord as a handle.
- Keep away from all solvents and harsh detergents.
- Unplug the device and allow it to cool before cleaning. Wipe with a soft, dry cloth as
needed.
- Do not submerge the device in water or other liquids.
- Do not use abrasive cleaners, brushes, gasoline, kerosene, glass/furniture polish, or paint
thinner to clean the massager.
PREPARATION
- Please put the device under
your waist between lumbar
no. L1 and L5.
- Please place device on a hard
surface or use a hard cushion
under the device to keep level
for operation.
FEATURES
- Air traction system with ergonomically designed to fit body curves
- Infrared light and heat therapy with adjustable temprature level
- Vibration massage with two high-power 3000 rpm motors
- Includes one electromagnetic chip and EMS pads for massaging other body parts
- ABS & PC materials supporting more than 200 kg of weight
NOTE
- The default time for infrared heat therapy is 15 minutes. After a 10-minute break, press
the on/off button on the control panel again if you need more cycles.
- In different mode, some buttons for different functions will be locked.
- This device is only used for waist.
- Do not contact skin directly with this device.
1. The base plate must be placed beneath
the device
2. The plate was designed to improve the
overall experience when using the
traction device on a soft surface
3. You can operate the traction device with
or without the plate when the device is
placed on hard surface
4. Do not tread on the plate or use it for
other purposes
The traction strength will be moderate
when the device is laid on this side
The traction strength will be stronger
when the device is laid on this side
EN
EN
EN
EN
EN
EN
Lumbar
Traction
Device
R2