background image

RolTop roller shutter drive

GB

Device functions:

• Blind protection (torque limiting)
• Commissioning the drive with the assembly cable.

As-delivered condition

(commissioning mode)

• Setting end positions

Keep these instructions in a safe place!

After installation of the tubular drive attach these instructions  
to the cable for the electrician.

Warning!

Important safety instructions!
Observe the following instructions.

Risk of injury due to electrocution.

The connections to the 230 V mains 

must

be made

by authorised specialist personnel.
Check the system (roller shutter) regularly for wear
or damage.
The regulations of the local energy supply company 
as well as the regulations for wet and damp rooms
according to VDE 0100 must be followed when
making the connections.
Only use unmodified original 

elero

electrical parts.

Keep people away from the system until it is
stationary.
When working on the system (servicing, cleaning
windows etc.), always disconnect it from the mains
supply.

Check the following before installation:

• The drive is only capable of operation as installed.
• Only perform connecting work with the power turned off.
• The blind must be attached to the winding shaft.
• The profile tube must have sufficient clearance from the motor

tube.

• Make sure there is sufficient axial play (1–2 mm)

Risk of injury due to electrocution.

Do not drill in the area of the motor! 

Warnung!

Installation in profile tubes

X

A

Push drive with relevant adapter 
and limit switch into the profile 
tube. 

Protect the motor cable in order 
to avoid it brushing against the 
roller shutter. Avoid kinking the 
cable.

X

B

Secure the counterpart support 
to prevent axial movement, 
e.g. screw or rivet on idler.

Secure the drive axially in the 
support.

X

C

Attach the blind to the shaft!

Installation

Observe the following installation instructions!

–  The drive must be fixed in such a way that it does

not endanger personnel.

–  Before installing the drive, all lines and equipment,

which are not required for operation, must be
removed from the site.

–  During installation, during operation and when

work is carried out on the system, the option to
separate all three poles from the mains must
always exist (Hirschmann connector and
Hirschmann coupling or a two-pole switch with
minimum 3 mm contact gap or all-pole main
switch).

–  If the drive is controlled by a switch with OFF 

pre-setting (dead man’s button), the momentary
contact switch must be fitted at a height of more
than 1.50 m and separated from the moving parts. 
The travel range of the systems must always be
visible during operation.

–  Moving parts in a drive, which are below 2.5 m,

must be guarded.

–  Set torque  and set operating time must be

adapted to the requirements of the product which
is driven. 

–  Please note the technical data on the type plate.

–  Please note that with this drive (type M motor) 

the smallest internal tube diameter corresponds
with 46 mm.

–  The drive must be installed so that it cannot get

wet.

–  Do not install drives in surroundings which are at

risk of explosion or in mobile appliances 
(e.g. motor vehicles).

–  Keep children away from the (remote) control unit.

Warning!

Remove of the motor cable plug

Risk of injury due to 
electrocution.

When the motor cable plug 
is removed the supply line 

must

be volt free.

Remove the motor cable plug

Switch off voltage supply.
1. Press locking mechanism on the plug towards the cable using a

screwdriver.

2. Pull out the plug.

Insert the motor cable plug

3. Switch off voltage supply. Insert plug until locking mechanism

engages.

Delivery condition

2

Insert plug

Remove plug

1

3

Warning!

S

S

S

B

A

C

Summary of Contents for RolTop Series

Page 1: ...Secure the drive axially in the support X C Attach the blind to the shaft Installation Observe the following installation instructions The drive must be fixed in such a way that it does not endanger personnel Before installing the drive all lines and equipment which are not required for operation must be removed from the site During installation during operation and when work is carried out on the...

Page 2: ...tapes freely programmable belt 2 Fixed upper stop T strap tapes lower stop freely belt limit plugs adjustable angle bracket 3 Fixed upper and Anti push up device lower stop limit plugs angle bracket 4 Upper limit position freely Anti push up device programmable fixed lower limit stop Connection example RolTop Rohrmotor 230 V 50 Hz Note You can connect several RolTop drives in parallel Please note ...

Page 3: ...it stop It is possible to make corrections using the momentary contact switches Note Ensure that the equipment is correctly connected STOP 6 Press the UP momentary contact switch until the drive stops automatically The lower limit has been set Setting of the end positions is now complete 2 Press the UP momentary contact switch again Go to the desired upper end position It is possible to make corre...

Page 4: ...d down until it is a short distance above the desired lower limit stop The drive starts up slowly with a short STOP 1 Move the blind up to approx 5 cm before the upper limit stop The drive starts up slowly with a short STOP STOP 3 Press the DOWN momentary contact switch until the drive stops automatically The upper limit stop is programmed Installation Method 2 Fixed upper stop lower stop freely a...

Page 5: ...he drive switches off automatically when it reaches the limit stop Note Ensure that the equipment is correctly connected STOP 6 Press the UP momentary contact switch until the drive stops automatically The lower limit has been set Setting of the end positions is now complete 2 Press the UP momentary contact switch again Approach the upper limit stop The drive switches off automatically when it rea...

Page 6: ...t is correctly connected STOP 6 Press the UP momentary contact switch until the drive stops automatically The lower limit has been set Setting of the end positions is now complete 2 Press the UP momentary contact switch again Go to the desired upper end position It is possible to make corrections using the momentary contact switches 4 Press the DOWN momentary contact switch again Run the blind unt...

Page 7: ...g the limit positions 1 Switch on mains 2 Move the blind to an intermediate position approx 5 sec 3 Press both momentary contact switches on the assembly cable simultaneously The drive travels up and down briefly after approx 5 seconds Deletion of the limit positions is complete You can now re programme the limit positions ...

Page 8: ... connection direction Drive does not react No power supply Check mains voltage Thermostat has triggered Allow drive to cool down Drive does not learn in Random travel Delete limit positions limit positions Re programme limit positions Travel to limit position stop too short Drive has to travel to short STOP Troubleshooting We reserve the right to make technical changes 08 07 20 elero GmbH Antriebs...