Operation Manual 

SERIES 

IZ15E 

 

Battery powered Length measuring System

Battery powered Length measuring System

Battery powered Length measuring System

Battery powered Length measuring System    
 
Predestined for the mobile assembly on manual sledges, carriage and back 
stop systems 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Battery powered indicator 

 

LCD Display 

Summary of Contents for IZ15E

Page 1: ...asuring System Battery powered Length measuring System Battery powered Length measuring System Battery powered Length measuring System Predestined for the mobile assembly on manual sledges carriage and back stop systems Battery powered indicator LCD Display ...

Page 2: ... 5 2 Technical Data 14 6 Installation 15 6 1 Qualifications of the Staff 15 6 2 Description of the assembly Installation 15 6 3 The Sensor 15 7 Structure and Function 16 7 1 Selecting parameters and input 16 7 1 1 Parameter level activate 16 7 1 2 Accessing the Decade 16 7 1 3 Change the value 16 7 1 4 Sign 16 7 1 5 Leaving Parameter level 16 7 1 6 Parameters 17 7 2 Default Parameter Calibration 1...

Page 3: ...le and can be slightly different to the actual construction 1 2 Explanation of Symbols Warning notices Warning notices Warning notices Warning notices Warning notices are characterised by symbols in the operation manual The notes will be introduced by signal words to express the magnitude of the danger Follow these advices in order to avoid accidents and injuries to persons and property DANGER DAN...

Page 4: ...s are used in order to point out possible hazards DANGER DANGER DANGER DANGER marks perilous situations by electricity By non observance of the safety instructions the possibilities of death or severe injuries exist The operations have to be carried out only by an electrician 1 3 Statement of Warranties The warranty conditions are in a separate document Guarantee Guarantee Guarantee Guarantee The ...

Page 5: ... Disposal Disposal Disposal Recycle the decomposed elements Scrap metal elements Recycle plastic parts Dispose the rest of the components according to their material consistence ATTENTION ATTENTION ATTENTION ATTENTION Wrong disposal damage caused to the environment Electronic waste electronic components lubricants and operating supplies are liable to treatment of hazardous waste Only approved spec...

Page 6: ...he work process Also observe any labels in the operating area regarding protective clothing Protective clothing Protective clothing Protective clothing Protective clothing Safety workin Safety workin Safety workin Safety working clothing g clothing g clothing g clothing is close fitting is tear proof has tight sleeves without distant parts Also wear no rings necklaces or other jewellery Also wear ...

Page 7: ...ictly follow this manual Avoid in particular Remodelling refitting or changing of the device or parts of it with the intention to alter functionality or scope of the position indicator ELGO is not liable for any damages resulting from improper use of the product 3 Transport and Storage 3 1 Safety Instructions for Transport Unpacking and Loading ATTENTION ATTENTION ATTENTION ATTENTION Professional ...

Page 8: ...t immediately ADVERT ADVERT ADVERT ADVERT Claim any damages you recognize as soon as possible The claims for damage must be filed in the lawful reclaim periods 3 4 Storage Store device only under following conditions Do not store outside Keep dry and dust free Do not expose to aggressive media Protect from direct sun light Avoid mechanical shocks Storage temperature 20 to 50 C Relative humidity 60...

Page 9: ...LGO MB20 25 10 1 R 2 5 mm Pole pitch in respect of which the sensor the necessary information current position returns The sensor head is with its high class protection against any kind of dust dirt and water jets and absolutely wear resistant The distance to the magnetic tape to the sensor may be up to 0 8 mm The display has extensive programming including pulse temperature decimal places Countin...

Page 10: ... 10 5 Technical Data 5 1 Dimensions 5 1 1 Dimensions Indicator 5 1 2 Dimensions Sensor Seal Seal Seal Seal Technical Data ...

Page 11: ...XX X 0 Version with standard cable outlet Display with external sensor fixed cable outlet standard sensor cable length 1 0 m supply via cable outlet Length 200m for external battery compartment not included available as accessory Technical Data ...

Page 12: ... 12 5 1 3 2 Battery Sets for IZ15E 000 3 XX X 0 a Battery Set 1xC Installation b Battery Set 1xC Open Technical Data ...

Page 13: ... 13 5 1 3 3 IZ15E 000 4 XX X 0 Display with external sensor fixed cable outlet standard sensor cable length 1 0 m supply of Type 2AA battery compartment on the back batteries are included ...

Page 14: ... H x D 72 x 48 x 23 mm Installation depth 30 mm incl cable Front panel outbreak W x H 68 x 45 mm Protection class IP 43 installed Magnetic Sensor MS20 25 Sensor cable length 0 1 m up to max 2 0 m more on request Resolution 0 1mm Protection class IP66 Zinc die cast Operation temperature 5 up to 50 C min Radius to bend min 60 mm Distance Sensor Tape max 0 8 mm without cover tape C Magnetic Tape MB 2...

Page 15: ...ngle plate is also an assembly possibility The device IZ15 comes with a seal This is necessary to guarantee spray and dust protection 6 3 The Sensor The sensor integrates the magneto resistance test bridges from which addicted to the track the counts for the signal processing electronic are formed The distance between the sensor and band within the range X may not be larger than 1 0 mm Each smalle...

Page 16: ...able parameters can be successive selected 7 1 2 Accessing the Decade Set 1x press With this button the Decade will be forwarded at 1 point from the left to the right The selected Decade is blinking 7 1 3 Change the value 1x press With this button the value of the selected decade will be increased at 1 0 9 or 0 1 7 1 4 Sign 1x press With this button you can adjust at some parameters the sign 7 1 5...

Page 17: ...ing A 0 mm Mode A 1 Inch Mode Resolution 0 001 Inch 0 P03 A Decimal point 0 3 1 P05 ABC Key lock A Button SET 0 active 1 not active B Button Incr Abs 0 active 1 not active C Button 0 active 1 not active 000 P08 Multiplication factor 0 0001 9 9999 1 0000 P09 Reference value 999999 9 999999 9 0 0 P10 Offset 1 999999 9 999999 9 0 0 P11 Offset 2 999999 9 999999 9 0 0 P12 Offset 3 999999 9 999999 9 0 0...

Page 18: ... calibration display CAL 0 CAL 4 is the display again in normal mode 7 2 2 Loading the Default Parameter The Sensor must be installed on the Magnetic tape Switch off the unit press this button While pressing this button switch the unit on again Here all parameters will be reset to default parameters Also herewith the calibration of the sensor is triggered and CAL 0 is shown in the display Now move...

Page 19: ...is key the unit switch from absolute mode to incremental mode The display value is set to zero and display the symbol INC Pressing the button again the display set again into absolute mode and abs is shown again 7 3 3 Activate offsets 1x press This button activates the three adjustable offsets Herewith an offset will be added to the actual shown value Only in the ABS mode possible The activation o...

Page 20: ...gnetic tape MB 20 MB 20 MB 20 MB 20 25 25 25 25 10 10 10 10 1 1 1 1 R R R R The magnetic tape consists of 3 components available lengths 0 5 32 m 1 8mm C A B Befestigungsseite Sensorseite L 10mm Structure and Function Sensor side Installation side ...

Page 21: ...refore Fault clearance may only be carried out by qualified and instructed personnel Prior to the beginning of work provide sufficient room to assemble the equipment Please look for cleanliness at the place of installation loosely around laying parts and tools are sources of accidents If components have to be replaced Look for correct installation of spare parts All mounting elements have to be as...

Page 22: ... follows 1 Add RC elements over contactor coils of AC contactors for example 0 1 µF 100 Ω 2 Add recovery diodes over DC inductances 3 Add RC elements over each drive phase in connector box of the drive 4 Do not connect the GND potential with PE earth potential Install a power filter before the external power supply 8 2 Restart after fault clearance After fault clearance 1 Reset emergency stop swit...

Page 23: ...nused arteries in signal lines should be isolated from each other separately isolate signal and power lines separately in long parallel lines a distance of 300 mm is respected therefore should never be different voltage levels e g 230V 50 Hz power supply and measuring signal 24V DC in one cable together low the emission by the Installation of filter networks in plants with frequency In the operati...

Page 24: ...gth Sensor cable length Sensor cable length Sensor cable length e g 02 0 2 0 Meter max length 2 0 Meter c c c cab ab ab able le le le o o o option ption ption ptions s s s 0 hard cable outlet Standard 1 Sensor plug in in preparation Options Options Options Options if needed 11 Accessories MB20 MB20 MB20 MB20 25 25 25 25 10 10 10 10 1 1 1 1 R R R R Magnetic tape MB 20 25 10 1 R Designation MB20 inc...

Page 25: ...1 L O Operation manual 3 M Maintenance 23 P Parameter 17 Protection clothing 6 Purpose of Use 7 R Reference value 19 S Security 6 Storage 8 Suppress interferences 22 Symbols 3 T Technical Data 14 Transport 8 Type Designation 24 Dok Nr 799000419 IZ15 000 E_36 08 Subject to change 2008 ELGO Electronic GmbH Co KG Register ...