97460C (Rev. SIB - 6/06)

4595_FTN

Owners Manual

Model 4595

Pedestal Barrier Free Stone Fountain

To assure you install your 4595 Stone Fountain model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation,
leave these instructions with the Fountain for future reference.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN
FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE
FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

INSTALLER

General Installation Tips

1. Water supply 3/8" O.D. unplated copper  tube. Waste 1-1/4" IPS. Contractor to supply waste trap and service stop valve
    in accordance with local code.
2. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before
    being connected to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste,
    odor, color, or sediment problems.
3. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and
    the cooler. Remove any burrs from outside of water line. Push the tubes straight into the fittings until they reach a
    positive stop, approximately 3/4" (See Fig. 6). 

DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS

    DAMAGE TO THE O-RINGS MAY RESULT.

4. These products are designed to operate on 20 psig to 105 psig supply line pressure. If inlet pressure is above 105 psig,
    a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this product to
    supply line pressures lower than 20 psig or higher than 105 psig is not covered by warranty.

Summary of Contents for 4595

Page 1: ... THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM INSTALLER General Installation Tips 1 Water supply 3 8 O D unplated copper tube Waste 1 1 4 IPS Contractor to supply waste trap and service stop valve in accordance with local code 2 Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being connected to fountain This fountain is manufact...

Page 2: ...3 Install shut off valve on water supply Valve not furnished 4 Locate and install fountain using 3 8 minimum screws or bolts Screws or bolts not furnished CAUTION This fountain is rated for inlet water pressure of 20 105 PSI A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI 5 Connect water supply and fountain drain Water connection and drain must comply with lo...

Page 3: ...eatly from this remove items 7 and 8 See Fig 3 and adjust screw on item 19 Clockwise adjustment will raise stream and counter clockwise adjustment will lower stream For best adjustment stream should hit basin approx 6 1 2 from bubbler FIG 2 FIG 3 FIG 4 8 4 19 13 10 7 11 22 16 16 16 15 12 1 20 23 3 1 14 24 23 22 5 2 2 9 B 6 3 2 5 16 18 21 16 BUBBLERDETAIL ...

Page 4: ...ARTS LIST FIG 6 NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 4 O D TUBE WATER INLET TO FOUNTAIN 3 8 O D UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY TROUBLE SHOOTING AND MAINTENANCE Orifice Assy Mineral deposits on orifice can cause water flow to spurt or not regulate Mineral deposits may be removed from the orifice with a small round file or small diameter wire CA...

Reviews: