background image

02-186/2016 Rev.: 1

1 / 2

CRM-91H
CRM-93H
CRM-9S

 A1   

16     18     26     28     36     38    

S       A2

 15         

 25         

 35         

CRM-93H

 15         

16     18    

 A1   

  S       A2

CRM-91H

CRM-9S

 A1/B1  

S      A2

 18     18   

+

+

16     18    

 15         

S        A2

 A1   

Un

CRM-91H

CRM-9S

+

 15  16  18

 A1   S    A2

-

Un

CRM-93H

-

+

 A1   S    A2

 35  36   38

 25  26   28

 15  16  18

Un

 B1  18  18

 A1   S    A2

Un

cos φ ≥ 0.95

M

M

HAL.230V

K

M

M

cos φ ≥ 0.95

M

M

HAL.230V

K

M

M

AC12

250V / 10A

DC14

24V / 2A

AC1

250V / 16A

AC13

250V / 6A

AC2

250V / 5A

AC14

250V / 6A

AC3

250V / 3A

AC15

250V / 6A

AC5b

800W

DC5

24V / 4A

AC6a

x

DC12

24V / 16A

AC7b

250V / 3A

DC13

24V / 2A

AC12

250V / 1A

DC14

x

AC1

250V / 8A

AC13

x

AC2

250V / 3A

AC14

250V / 3A

AC3

250V / 2A

AC15

250V / 3A

AC5b

300W

DC5

24V / 2A

AC6a

x

DC12

24V / 8A

AC7b

250V / 1A

DC13

24V / 2A

CRM-93H

CRM-91H

Made in Czech Republic

Multifunction time relay

- Multifunction time relay can be used for electrical appliances, control of lights, 

heating, motors, pumps and fans (10 functions, 10 time ranges, multi-voltage, 
16 A or 3x 8 A contacts).

- Fulfi lls all requirements for time relays
- 10 functions:   - 5 time functions controlled by supply voltage

           - 4 time functions controlled by control input
           - 1 function of latching relay

- Comfortable and well-arranged function and time-range setting by rotary switches.
- Time scale 0.1 s - 10 days divided into 10 ranges: (0.1 s - 1 s / 1 s - 10 s / 0.1 min 

- 1 min / 1 min - 10 min / 0.1 hrs - 1 hrs / 1 hrs - 10 hrs / 0.1 day - 1 day / 1 day - 
10 days / only ON / only OFF).

- CRM-91H, CRM-93H: 

- universal supply voltage AC/DC 12 - 240 V or AC 230 V
- output contact: CRM-91H: 1x changeover/SPDT 16 A

                                        CRM-93H: 3 x changeover/SPDT 8 A
-  CRM-9S: 

- universal supply voltage AC 12 - 240 V, absolutely noise-less switching.
- 1x static contactless output (triac) 0.7 A (60 A / <10 ms), switches potential A1.

- Multifunction red LED output indicator fl ashes or shines depending on the status 

of output.

- 1-MODULE, DIN rail mounting.

Characteristic

Description

Symbol

Connection

Load

Possibility to connect load onto controlling input: 

It is possible to connect the load (e.g.: contactor) 
between terminals S-A2, without any interruption 
of correct relay function.

AC5a 

uncompensated

230V / 3A (690VA)

DC1

24V / 16A

AC5a 

compensated

x

DC3

24V / 6A

Type of load

mat. contacts AgNi, 

contact 16 A

Type of load

mat. contacts AgNi, 

contact 16 A

AC5a 

uncompensated

230V / 1.5A (345VA)

DC1

24V / 8A

AC5a 

compensated

x

DC3

24V / 3A

Type of load

mat. contacts AgNi, 

contact 8 A

Type of load

mat. contacts AgNi, 

contact 8 A

1) Output contacts of CRM-93H do not allow switching of diff erent phases or 3-phase 

voltages (voltage > 250 V).

2) When mounting into steal-plated switchboards, it is necessary to keep a safety distance 

of min. 3 mm from terminal’s screws 35-36-38 and 25-26-28 towards the shutter of a 
switchboard.

Notes

CRM-93H

8

1

3
4

7

7

7

2

5
6

CRM-9S

1

8

3
4

7

2

5
6

1. Supply terminals
2. Control. input “S”
3. Supply indication
4. Rough time setting
5. Fine time setting
6. Function setting
7. Output contact
8. Output indication

ELKO EP, s.r.o. 

Palackého 493
769 01 Holešov, Všetuly
Czech Republic 
Tel.: +420 573 514 211
e-mail: elko@elkoep.com
www.elkoep.com

EN

Reviews: