Solexa II

Rad io control system

Operation

Item numbers 10144 (Display), 10150 (Set)

Technical support: +49 (0) 70 33 / 30 945-250

 

Elsner Elektronik GmbH 

Control and Automation Engineering

Sohlengrund 16
75395 Ostelsheim

Phone +49 (0) 70 33 / 30 945-0

info@elsner-elektronik.de

Germany

Fax

+49 (0) 70 33 / 30 945-20 www.elsner-elektronik.de

EN

Summary of Contents for 10144

Page 1: ... Display 10150 Set Technical support 49 0 70 33 30 945 250 Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de EN ...

Page 2: ...menu area whether a more up to date version of this document is available Key to the symbols Installation testing operational start up and troubleshooting of the unit should only be performed by an electrician accredited according to VDE 0100 Safety information Safety information for working on electrical connections compo nents etc DANGER indicates an immediately hazardous situation which will le...

Page 3: ...us 6 3 Time day of the week 7 4 Settings menus 7 5 Room temperature and weather data 7 6 Time reception weather station 7 7 Active output functions 7 8 Rocker switch for manual operation 8 1 3 1 Meaning of the functional symbols automatic mode status 8 Shading shutters awnings blinds 8 Window 9 Light 10 Heating 10 Roof gutter heating 10 1 4 Beeps 11 1 5 Error messages 11 1 6 Table Memory locations...

Page 4: ...4 Contents Solexa II Control from software version weather station 1 3 display 2 1 Version 11 05 2017 Technical changes and errors excepted ...

Page 5: ...acturer Charge the display before initial start up To charge connect the display via a USB socket with a mains socket charging device or a PC The charging device must have a charging current of 200 mA or more If the device is not charged in time the display switches off If a weather station is being used in the system then the automation is not affected The automation continues to run without the ...

Page 6: ...c functions for the selected output are active Manual mode Output was operated manually or switched to manual mode After an output has been operated manually it remains in manual mode Auto matic mode is inactive Set an automatic mode reset so that the output switches back to automatic once a day or after a certain time after being operated manually see Gen eral settings chapter Automatic reset in ...

Page 7: ...ch between the Temperature display and the Brightness Wind display Temperature display Current outdoor temperature only if a weather station is being used Current indoor temperature Brightness wind display only if a weather station is being used Current brightness light intensity Current wind speed Further information on the values for brightness and wind is in the manual chapter Units for sun and...

Page 8: ...tion active 1 3 1 Meaning of the functional symbols automatic mode status The symbols show the automatic mode status for the selected output and the alarm functions valid for the manual mode A function is only displayed if it has been activat ed for the output Shading shutters awnings blinds Please note that for an action such as extend shading a number of conditions must be fulfilled The function...

Page 9: ...ing is extended if all other conditions are OK Brightness threshold value for shading has been exceeded Shading is performed if all other conditions are OK Brightness below threshold value for shading retraction delay is running Shading is retracted after the delay time has expired Brightness below threshold value for shading Sun protection automatic inactive Window Please note that for an action ...

Page 10: ...e detailed description of the automatic functions is in the Light Automatic mode chapter in the manual Values below twilight threshold value Lights are switched on after a delay of 1 minute If a lighting time period has also been set the lights are only switched on during this period Lighting time period active If twilight switching has also been set the lights are only switched on in twilight Hea...

Page 11: ...at a warning signal sounds every 15 minutes combination of high and low beeps 1 5 Error messages If instead of a sensor value ER error is displayed then the wireless connection to the weather station is disrupted or the sensor is defective Check whether the weather station is powered fuse Have the device checked by an electrician if the problem continues Installation testing operational start up a...

Page 12: ...2 Operating the display Solexa II Control from software version weather station 1 3 display 2 1 Version 11 05 2017 Technical changes and errors excepted Memory location Type Display position Room Keyword ...

Page 13: ...y The automatic control can start system components and place people in danger e g moving windows awnings if a rain wind alarm has been triggered while cleaning Always isolate the device from the mains for servicing and cleaning The device must regularly be checked for dirt twice a year and cleaned if necessary In case of severe dirt the sensor may not work properly anymore ATTENTION The device ca...