Radio motor control unit RF-MSG-ST IP53
1
Radio motor control unit RF-MSG-ST IP53
• Version: 08.06.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de •
Technical Service: +49 (0) 7033 / 30945-250
EN
RF-MSG-ST IP53
Radio Motor Control Unit
Technical specifications and installation instructions
Item number 60535
1.
Description
The
RF-MSG-ST IP53
is a radio motor control unit for one drive (e.g. shade or
window).
A connected drive can be operated directly using the remote controls Remo 8/pro,
via the button interface RF-B2-UP or the solar radio button Corlo P RF.
If the drive shall execute automatic functions, the
RF-MSG-ST IP53
is taught into
the radio chanells of the WS1 Color/Style, WS1000 Color/Style, WS1000 Connect or
Solexa II controls.
Functions:
•
Control of drives for shading elements (e.g. blinds) or windows
•
1 connection for 230 V-drive (STAK3)
•
Reception of the radio control signal
•
Suitable for: WS1 Color, WS1 Style, WS1000 Color, WS1000 Style, KNX
WS1000 Style (from software version 1.20).
WS1000 Connect. Solexa II.
Remo 8 (from version 0.1), Remo pro, RF-B2-UP, Corlo P1 RF, Corlo P2 RF.
1.0.1. Safety advice
WARNING!
Risk of injury caused by components moved automatically!
If the wireless connection between the control unit and the wireless
actuator is interrupted, connected devices can no longer be operated.
•
For that reason do not connect drives to the wireless actuator which
could be hazardous to human life!
1.0.2. Scope of delivery
•
Radio motor control unit
Available accessories:
•
Mains connection wire (5 m)
•
Connection wire (available in 1 m; 2,5 m; 5 m)
1.1. Technical data
*The
Radio motor control unit RF-MSG-ST IP53
should be installed in a protec-
ted area despite a high protection category because water can enter in via the con-
nectors. Please observe the instructions in Chapter
Connection
.
The product conforms with the provisions of EU directives.
2.
Installation and start-up
2.1. Installation notes
Installation, testing, operational start-up and troubleshooting should
only be performed by an electrician.
DANGER!
Risk to life from live voltage (mains voltage)!
There are unprotected live components within the device.
•
VDE regulations and national regulations are to be followed.
•
Ensure that all lines to be assembled are free of voltage and take
precautions against accidental switching on.
•
Do not use the device if it is damaged.
•
Take the device or system out of service and secure it against
unintentional use, if it can be assumed, that risk-free operation is no
longer guaranteed.
The device is only to be used for the intended purpose described in this manual. Any
improper modification or failure to follow the operating instructions voids any and
all warranty and guarantee claims.
After unpacking the device, check it immediately for possible mechanical damage.
If it has been damaged in transport, inform the supplier immediately.
The device may only be used as a fixed-site installation; that means only when as-
sembled and after conclusion of all installation and operational start-up tasks and
only in the surroundings designated for it.
Elsner Elektronik is not liable for any changes in norms and standards which may
occur after publication of these operating instructions.
2.2. Notes on wireless equipment
When planning facilities with devices that communicate via radio, adequate radio
reception must be guaranteed. The range of wireless control will be limited by legal
regulation and structural circumstances. Avoid sources of interference and obstac-
les between receiver and transmitter, that could disturb the wireless communicati-
on. Those would be for example:
•
Walls and ceilings (especially concrete and solar protection glazing).
•
Metal surfaces next to the wireless participants (e. g. aluminium construction
of a conservatory).
•
Other wireless devices and powerful local transmitters (e.g. wireless
headphones), which transmit on the same frequency. Please maintain a
minimum distance of 30 cm between wireless transmitters for that reason.
2.3. Connection
The radio module is connected between the appliance and the power supply. It may
only be connected to flexible lines using STAK/STAS connectors. The connectors
must be locked using the locking bow.
Do not expose to continuous sun radiation
to avoid overheating.
The housing is not UV-resistant.
•
Assembly the device in a protected area (e. g. in
the box for the blinds/marquee/shutters in a construction
profile beneath the roof tiles or in a housing).
No water may run along the supply line and device
because water
can enter in via the connectors
.
•
Assembly the device in a protected area (e. g. in
the box for the blinds/marquee/shutters in a construction
profile beneath the roof tiles or in a housing).
•
Lay the supply lines out and down from the device.
No vibrations!
•
Assemble the device in a place that is free of vibrations.
2.3.1. Connection scheme
Housing
Plastic
Protection category
IP 53*
Dimensions (without
locking bow)
approx. 147 x 36 x 29 (W x H x D, mm)
Weight
approx. 140 g
Ambient temperature
Operation -25…+70 °C, storage -30…+85°C
Ambient humidity
max. 95% RH, avoid condensation
Operating voltage
230V AC
Input
STAS3 plug, 230 V AC, 50 Hz
Output
1 × drive, STAK3 coupling, 230 V AC (up/down/N/PE),
loadable to max. 4 A / 230 V AC
Radio frequency
868.2 MHz (Elsner RF)
Fig. 1
The antenna symbol on the housing shows the positi-
on of the antenna in
RF-MSG-ST IP53
. This side must
not be positioned directly on metal surfaces or objects.
Otherwise, the radio signal might disturbed.
Metal
profile
RF
-MSG
-ST
Abb. 2
Mains / Power
230 V AC
M