background image

AMPLIMAX

EPRL16

USER MANUAL

Maximum performance 

for Internet in low or 

nonexistent locations.

EASY 

INTERNET

Summary of Contents for AMPLIMAX EPRL16

Page 1: ...AMPLIMAX EPRL16 USER MANUAL Maximum performance for Internet in low or nonexistent locations EASY INTERNET ...

Page 2: ...lections Due to these factors it is not possible to predict it accurately Based on the experiences already made and published in the literature we present below an estimated comparison between two scenarios Scenario 1 USB modem connected indoors Scenario 2 AMPLIMAX ELSYS installed on the roof at a height of 5 meters The table below describes the improvement in the range and level received from AMP...

Page 3: ... location 6 Display 4 digits Displays equipment information A Connector for external antenna and LED indicator Internal Antenna LED off External Antenna LED on Use only in extreme cases and with cable up to 1 5m max B Switching key between internal and external antenna WiFi NOTEBOOK PC B 1 3 4 5 6 ANT EXT ANT INT EXT RJ45 POE 4G SIM CARD A 2 SIM CARD NANO OR PRODUCT DETAILS AMPLIMAX CONNECTIONS PO...

Page 4: ...bly check the Cable Assembly section in this manual Use cable approved by FCC especially if the length is greater than 33 ft POE INSTALLATION The POE must be installed indoors and connected to the source computer telephone and AMPLIMAX as shown in the diagram above INSTALLATION Wi Fi or The installation of AMPLIMAX must be done according to the simplified diagram below GENERAL CONNECTIONS MAP The ...

Page 5: ...gure on the side The Blind Search may take a few minutes depending on the location and configuration of the product At the end of this period the display will show the list of available cellular networks organized by technology E g 4G and 3G and the level of each one See list of networks in OPERATION If no cellular networks are found try searching elsewhere The search will only be performed on the...

Page 6: ... cellular network it will display its name followed by its band signal level and technology in a cyclical manner ANTENNA POINTING FIT THE REFLECTOR TO THE CABINET TOP TO BOTTOM SIM CARD POSITIONING ANT EXT ANT INT EXT RJ45 POE 4G SIM CARD ANT EXT ANT INT EXT RJ45 POE 4G SIM CARD 1 2 3 POE Fit the reflector to the back of the cabinet It must sliding like a drawer up to the limit of the path At the ...

Page 7: ...s installed the better the signal level Usually a level above 30 already allows the use of the product Even so the higher the level received the better it can be the stability of your Internet It is important to always seek the highest possible signal level Once the best position and pointing has been identified just press the Easy Install key once to exit this mode The wall installation can be do...

Page 8: ...dress automatically option is enabled Press OK and exit all screens Enter your browser and start using the Internet Advanced setting can be made through the product setting page as described in the item WEB Setting Page VERIFYING THE INSTALLATION Typically the installation will be completed in this step After energizing the product wait 1 and a half minutes Check then that it is already possible t...

Page 9: ...n which the equipment is registered 91 to 99 61 to 90 31 to 60 0 to 30 70 dBm 90 to 70 dBm 100 to 91 dBm 100 dBm RECEIVED LEVEL dBm RSRP 4G 90 dBm 110 to 90 dBm 120 to 11 dBm 120 dBm QUALITY EXCELLENT GOOD ACCEPTABLE WEAK SIGNAL Displays the current signal level where XX is the percentage of the signal level This value varies between 00 and 99 The higher the value the better the signal Unidentifie...

Page 10: ...ble to enable or disable data collection as well as to know its details The maximum cable length must be 1 5m EXTERNALANTENNA Although this product is integrated with a high performance Heptaband antenna it allows the installation of an external antenna in a practical way in a TNC connector but there is an important detail about the cable length To avoid signal loss the external antenna installati...

Page 11: ...ing connect the two ends at the indicated locations and test to ensure that there is no short or interruption The LEDs must light up in numeric pairs If not review the connectors MOUNTED NETWORK CABLE RJ 45 Ethernet Place the connector on the crimping pliers Tighten firmly until the end of the pliers stroke when you hear a click Repeat this process with the other end of the cable Insert the connec...

Page 12: ...riginal power supply supplied by ELSYS replaced by any other one of a different or generic brand 7 Shipped for repair without the power supply GENERAL NOTES Use only original AC DC adapter Incompatible accessories compromise the operation safety and warranty of the product The AMPLIMAX power source must operate at 100 240VAC Check the local voltage before connecting the device If you want to clean...

Page 13: ...the received signal in dB Network frequency Frequency used by Amplimax Lac Area location code CelllD Base station identification Power over Ethernet voltage POE Product Supply Voltage Module temperature RF module temperature Phone Usage Informs if the voice service was used Scheduled Reset Informs if the programmed reset is enabled IPV6 Tells whether IPV6 is enabled Connection Status Informs if th...

Page 14: ...wser of your choice and enter the IP address of the AMPLIMAX the factory default is 192 168 10 254 If all connections are correct the product setting page can be accessed IN THE TOP MENU PERFORM THE FOLLOWING STEPS 1 Choose the option 2 Answer the question about authorization for data collection 3 Select Apply Yes No Apply Decide later Terms of using 2 1 3 To further enhance your experience of usi...

Page 15: ...on of the tower among other factors 4 The external RJ 45 cable can reach 328ft without signal loss This cable is not included 5 Remote monitoring of cameras and alarms depends on the carrier the contracted plan pre or post and the resources available on the cameras or DVRs 6 To access the Internet it is necessary to acquire SIM Card nano with data plan enabled The SIM card is not included Tested c...

Page 16: ...w Philips or slit S6 S7 or S8 bushing PRODUCT FASTENING ON THE MAST AMPLIMAX Lite can be fixed to both mast and wall To attach to a mast first wrap the two pieces of the self fusing tape on the mast The spacing between the two pieces of tape should be around 2 6 measured from center to center Template 2 6 in center to center Template 2 8 in ...

Reviews: