Wireless signal generator pure white
glossy for single mounting 80x80x17mm
or mounting into the E-Design55 switching
system. Internal acoustic signal generator
for a minimum volume of 80 dB. Power
supply 230 V. Only 0.8 watt standby
loss. Smart Home sensor.
Up to 24 wireless universal pushbuttons,
wireless window contacts, window
handles, smoke detectors FRWB, water
sensors as well as motion sensors
FB65B and FBH65SB can be taught in.
Mounting
over a 55 mm switch box.
16 mm over and 33 mm into the box.
230V power suppl y terminals on the rear.
Startup:
After power supply is switched on, the
teach-in mode is activated automatical-
ly for 2 minutes if the memory is empty
(as-delivered state) or if the teach-in
mode was not blocked. Teach-in stand-
by is alerted by a short beep.
Teach in wireless pushbutton:
Universal pushbutton:
tap briefly 3 times;
Direction pushbutton:
tap briefly 4 times;
Doorbell pushbutton:
tap briefly 5 times.
Wireless window contact:
Close and
open the window briefly 3 times;
Wireless window handle sensor FFG7B:
(EEP: A5-14-09)
Wireless window/door contact FTKB-hg:
(EEP: A5-14-0A)
Wi l
i
FB65B
GB
30 055 068 -
1
Wireless indoor UP signal
generator
FIUS55E
Only skilled electricians may install
this electrical equipment otherwise
there is the risk of fire or electric
shock!
Temperature at mounting location:
-20°C up to +50°C.
Storage temperature: -25°C up to +70°C.
Relative humidity:
annual average value <75%.
(EEP: A5 14 0A)
Wireless motion sensor
FB65B,
FBH65SB:
(EEP: A5-07-01)
Smoke alarm and water sensor:
(EEP: A5-30-03)
Wireless water probe FWS81:
Press
briefly the piston slide valve once.
GFVS:
(EEP: A5-38-08) this automati-
cally switches on confirmation tele-
grams and blocks the teach-in mode.
After a pushbutton is taught in, it is
confirmed by a short acoustic signal;
the teach-in mode is active for a further
2 minutes.
To avoid teach-in by accident, the
teach-in mode is blocked automatically
2 minutes after the last teach-in if a
universal or a direction pushbutton was
previously taught in. This is alerted by
two short beeps.
Block teach-in mode immediately:
Tap the pushbutton under the front
panel or an already taught-in direction
pushbutton 3 times short and once long
(>2 seconds). Blocking is signalled by
two beeps.
Unblock teach-in mode:
Tap the pushbutton under the front panel
or an already taught-in direction push-
button 4 times short and once long
(>2 seconds).
Teach-in standby is signalled by a short
beep.
Clear memory content completely
(restore as-delivered state):
1. Switch the power supply off and on.
2. Tap the pushbutton under the front
panel or an already taught-in direction
pushbutton 8 times short and once
long (>2 seconds).
Clear is signalled by a short acoustic
signal.
3. Apply on 'Teach in wireless push-
button'.
Switch on/off confirmation telegrams:
1. Switch the power supply off and on.
2. Tap the pushbutton under the front
panel or an already taught-in direction
pushbutton 7 times short and once
long (>2 seconds).
ON is signalled by two short acoustic
signals.
OFF is signalled by a short acoustic
signal.
Deactivate acoustic signal generator
for alarm:
1. Switch the power supply off and on.
2. Tap the pushbutton under the front
panel or an already taught-in direction
pushbutton 5 times short and once
long (>2 seconds).
Deactivation is signalled by two short
acoustic signals.
Activate acoustic signal generator for
alarm (as-delivered state):
1. Switch the power supply off and on.
2. Tap the pushbutton under the front
panel or an already taught-in direction
pushbutton 6 times short and once
long (>2 seconds).
Activation is indicated by a short
acoustic signal.
Switch on alarm standby:
(Alarm readiness is always active for
smoke alarm and water sensors)
Press top of direction pushbutton.
The
actuator is on alarm standby and
ON is
signalled by a triple acoustic signal. If a
monitored window is open or is opened
within 30 seconds after the alarm system
is enabled, a cyclical signal sounds imme-
diately indicating that the window is open.
The signal stops immediately the window
is closed.
After 30 seconds,
incoming
telegrams are evaluated by taught-in
sensors and the alarm is triggered if ne-
cessary.
After a power failure, the actuator returns
automatically to alarm standby.
Confirmation telegram: (ORG5) 0x30 =
alarm standby ON
Switch alarm standby or alarm off:
Press
bottom direction pushbutton
or
press the pushbutton under the front
panel for 10 seconds and then release.
Alarm standby is switched off and OFF
is signalled by a short beep.
Confirmation telegram: (ORG5) 0x10 =
alarm standby OFF
When an alarm occurs,
a beep sounds
1
d Th b
t
t