Installer Confi guration Menu

4

Operating Your Thermostat

6

Programming

6

Troubleshooting

8

Save these instructions for future use!

Description

Gas or Oil Heat

Yes

Electric Furnace

Yes

Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Pump (with Aux. or Emergency Heat)

No

Systems with up to 3 Stages Heat, 2 Stages Cool

No

Heat Only Systems

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Cool Only Systems

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

Blue Single 1/1 Stage Thermostat with 

Automatic Heat/Cool Changeover Option

PART NO. 37-6749D

Replaces 37-6749C

0902

Single Stage or Heat Pump

Installation and Operating Instructions for Model:

APPLICATIONS 

THERMOSTAT APPLICATION GUIDE

1F80-0471 Thermostat

SPECIFICATIONS 

Electrical Rating:
 

Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . .    mV to 30 VAC, NEC Class II, 50/60 Hz or DC

 

Input-Hardwire  . . . . . . . . . . . . . . . . . . . . . . . . .    20 to 30 VAC

Terminal Load  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range  . . . . . . . . . . . . . . . . . . . . . . . . . . . .    45° to 90°F (7° to 32°C)
Differential (Single Stage)  . . . . . . . . . . . . . . . . . . . .    Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump)  . . . . . . . . . . . . . . . . . . . . .    Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient . . . . . . . . . . . . . . . . . . . . . . . . . .    32° to +105°F (0° to +41°C)
Operating Humidity  . . . . . . . . . . . . . . . . . . . . . . . . .    90% non-condensing max.
Shipping Temperature Range  . . . . . . . . . . . . . . . . .    -4° to +150°F (-20° to +65°C)
Dimensions Thermostat. . . . . . . . . . . . . . . . . . . . . .    3.4"H x 4.4"W x 1.3"D

To prevent electrical shock and/or equipment damage, 
disconnect electric power to system at main fuse or 
circuit breaker box until installation is complete.

CAUTION

!

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this prod-
uct may replace a product that contains mercury.

Mercury and products containing mercury must not be 
discarded in household trash. Do not touch any spilled 
mercury. Wearing non-absorbent gloves, clean up any 
spilled mercury and place in a sealed container. For proper 
disposal of a product containing mercury or a sealed 
container of spilled mercury, place it in a suitable shipping 
container. Refer to 

www.white-rodgers.com 

for location to 

send product containing mercury.

 Model  

Programming 

Choices

 

1F80-0471

 

5/2 Day  5/1/1 Day  Non-Programmable

 

1F86-0471

 Non-Programmable

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS 
CAREFULLY BEFORE INSTALLING OR OPERATING THIS 
CONTROL COULD CAUSE PERSONAL INJURY AND/OR 
PROPERTY DAMAGE.

www.white-rodgers.com

Summary of Contents for 1F80-0471

Page 1: ...ntial Single Stage Heat 0 6 F Cool 1 2 F adjustable Differential Heat Pump Heat 1 2 F Cool 1 2 F adjustable Operating Ambient 32 to 105 F 0 to 41 C Operating Humidity 90 non condensing max Shipping Temperature Range 4 to 150 F 20 to 65 C Dimensions Thermostat 3 4 H x 4 4 W x 1 3 D Topreventelectricalshockand orequipmentdamage disconnect electric power to system at main fuse or circuit breaker box ...

Page 2: ...ing a call for heat If your heat is gas or oil the switch should be set to the GAS position When the thermostat is configured for Heat Pump the thermo stat will always power the circulator fan on a call for heat in the HEAT mode 2 Batteries 2 AA alkaline batteries are included in the thermostat To in stall the batteries pull the battery door as shown by the arrow and lift open Using the polarity i...

Page 3: ...Mode 7 Displays Run Schedule Schedule or Menu 8 Displays Save when Cool SavingsTM is working 9 Displays Heat Pump when system is configured as Heat Pump thermostat 10 Displays Hold in programmable mode when in Hold mode Displays Light Bulb in non program mable mode 1 Flame icon is displayed when the system is in HEAT mode Snowflake icon is displayed when the system is in COOL mode 2 The word Hold ...

Page 4: ...he displayed temperature to a maximum number of degrees selected Adjusting the setpoint temperature over a long cooling run time allows the system to reach your set temperature and turn off The room temperature will actually be higher than the thermostat displays but the reduction in humidity will allow comfort at the slightly higher temperature When Cool Savings is making adjustments Save will sh...

Page 5: ...ash the setpoint for up to five minutes 9 System Mode Configuration This thermostat is configured for Heat and Cool withAuto changeover SYSTEM switch with Cool Off Heat Auto default It can also be configured for Heat and Cool Cool Off Heat Heat only with fan Off Heat Heat only without fan Auto only Auto Off and Cool only Cool Off 10 Select Backlight Display The display backlight improves display c...

Page 6: ...d then press Schedule 3 The top of the display will show the day s being pro grammed The time and temperature flashing are also displayed 1 will also be displayed to indicate the period 4 Press or button to change the temperature to your selected temperature for the 1st heating period 5 Press Time button time will flash 6 Press or button to adjust the start time for the 1st period 7 The time will ...

Page 7: ...ing guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperatures will save energy If you plan on using Auto Changeover do not program the heating higher than the cooling Worksheet for Re Programming 5 2 Day and 5 1 1 Day Program PROGRAMMING For Programmable Model Only Wake Up Period 1 Leave For Work Period 2 Return Home Period 3 Go To ...

Page 8: ...k Try resetting the thermostat as described above If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system oper ates correctly replace the thermostat Thermostat Setting Thermostat Thermometer Disagree 1 Thermostat thermometer setting requires adjustment The thermometer can be adjusted 4 degr...

Page 9: ... 6 F frío 1 2 F ajustable Diferencial bomba de calor Calor 1 2 F frío 1 2 F ajustable Temperatura ambiente operativa 32 F a 105 F 0 C a 41 C Humedad operativa 90 sin condensación máx Rango de temperatura de transporte 4 F a 150 F 20 C a 65 C Dimensiones del termostato 3 4 pulg Al x 4 4 pulg An x 1 3 pulg P Paraevitardescargaseléctricasy odañosalequipo desconecte la alimentación eléctrica en la caj...

Page 10: ...rruptor debe ajustarse en la posición GAS Cuando está configurado para bomba de calor el termostato siempre activa el ventilador circulador en una llamada de calor en el modo HEAT pilas alcalinas AA Figura 1 Puerta del compartimiento de las pilas abierta Orificio de montaje Orificio de montaje Colocar nivelado a través de las lengüetas de montaje sólo por razones estéticas SS HP GAS ELEC Interrupt...

Page 11: ...ule programa o Menu menú 8 Muestra Save ahorro cuando Cool SavingsTM está en funcionamiento 9 Muestra Heat Pump bomba de calor cuando el sistema está configurado como termostato de bomba de calor 10 Muestra Hold mantener en el modo programable cuando está en el modo Hold Muestra Light Bulb bombilla en el modo no programable 1 El icono de la llama aparece cuando el sistema está en el modo HEAT El i...

Page 12: ...viene ajustada de fábrica en la posición O Esta posición admite la mayoría de las aplicaciones de bomba de calor que requieren que el relé de conmutación esté energizado en COOL Si el termostato que está cambiando o la bomba de calor en la que está instalando este termostato requiere una terminal B para energizar el relé de conmutación en HEAT el interruptor O B debe colocarse en la posición B 2 O...

Page 13: ...r del termostato la pantalla mostrará la temperatura de referencia de forma intermitente durante un máximo de cinco minutos 9 Configuración del modo del sistema Este termostato está configurado para calor y frío con opción predeterminada de conmutación automática interruptor SYSTEM con Cool Off Heat Auto También puede configurarse para calor y frío Cool Off Heat sólo calor con ventilador Off Heat ...

Page 14: ...AUTO el termostato cambiará a Heat o Cool según cuál fue el último que se ejecutó Si cambia a calor pero usted desea frío o si cambia a frío pero usted desea calor presione los botones o simultáneamente para pasar al otro modo Ajuste la hora y día actuales 1 Presione Menu y luego el botón Time una sola vez La pantalla mostrará la hora únicamente 2 Presione y mantenga presionado los botones o hasta...

Page 15: ...n programa de 5 2 días ingrese sus propias horas y temperaturas directamente a continuación debajo de las horas y temperaturas de fábrica Si desea reprogramar con un programa de 5 1 1 días complete todas las líneas con las horas y temperaturas que desea Tenga en cuenta las siguientes indicaciones cuando planifique su programa En calefacción las temperaturas más bajas ahorran energía En enfriamient...

Page 16: ...N Verifique todas las conexiones de los cables para asegurarse de que no estén en cortocircuito o tocándose entre sí No debe sobresalir ningún cable pelado por debajo del bloque de terminales Intente reajustar el termostato como se describe más arriba Si la condición persiste el fabricante de su sistema o el personal técnico podrá indicarle cómo probar si el sistema de frío calor está funcionando ...

Reviews: