background image

READ AND SAVE THESE INSTRUCTIONS

Raphael Model No.

CF2600AB01

CF2600WB01

CF2600PW01

Raphael 

II

Model No.

CF2650BC01

CF2650WB01

CF2650PW01

RAPHAEL

/ RAPHAEL 

II

Part No. F40BP72510004

Form No. BP7251-4

®

Net Weight:  

29.5 

Lbs.

Ceiling Fan Owner's Manual

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for a lifetime from the date you purchased your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Company Do To Correct Problems:
Emerson will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or
blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan.
WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL,
REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON.

How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of

Emerson Company, 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort
Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
• Repairs by persons not authorized by Emerson Company,
• Use of parts or accessories not authorized by Emerson Company,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON COMPANY IS NOT
RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to
such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which
was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Summary of Contents for BP7251

Page 1: ... return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage Wh...

Page 2: ...y U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceili...

Page 3: ...insure that all steps have been completed and will be helpful in finding your place should you be interrupted 18 DOWNROD ROD ASSEMBLY 3 BLADE FLANGES ROD SUPPORT ASSEMBLY HANGER BALL DOWNROD ASSEMBLY YELLOW LEAD ASSEMBLY UPLIGHT LIGHT KIT PLATE ASSEMBLY FAN MOTOR HOUSING AND SHADE ASSEMBLY CEILING COVER LOOSE PARTS BAG HANGER BRACKET MOTOR COVER GLASS SHADE LIGHT KIT ADAPTER ASSEMBLY Installed Wir...

Page 4: ...ed Consult a qualified electrician if in doubt WARNING Electrical Requirements IMPORTANT INSTALLATION INFORMATION Your ceiling fan contains a built in uplight assembly in the motor housing The fan and uplight may be controlled using one of the two following methods 1 By an Emerson SR330 Remote Control or SW350 Wall Control 2 By any other Emerson Fan Light Controls or by Standard Wall Switches Beca...

Page 5: ...t 3 above the motor coupling Figure 3A Strip insulation 1 2 from end of the white and blue wires Install a wire connector on the black wire this wire will not be used 7 Using wiring connectors supplied connect the white blue and yellow wires from the downrod to the white blue and yellow wires from the fan motor Figure 4A and 6A Wires must be connected color to color 8 Remove the wire connectors fr...

Page 6: ... the motor All wires and wire connectors must be enclosed under the motor cover NOTE Lightly snug the knurled knob and make sure the wires and wire connectors are completely inside the motor coupling cover and not pinched between the motor coupling cover and the motor 15 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with the large opening at the top Figure 9A ...

Page 7: ...ecessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 2 Figure 12A TOP OF HOUSING CANDELABRA BASE LAMP SOCKET Figure 10A 19 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to...

Page 8: ...the hole in the ceiling cover is clear of the downrod 29 Attach one blade assembly to the motor hub using two 10 32 x 5 8 oval head screws supplied Figure 17A Do not tighten completely at this time Install remaining blade assemblies in the same way Gently snug all flange screws to the motor hub working around the hub in a clockwise sequence Next securely tighten all flange screws again working in ...

Page 9: ...rs in the raised center portion of the plate assembly Do not pinch wires between the light kit plate assembly and the adapter assembly 33 Secure the light kit plate assembly to the light kit adapter assembly by threading three 5 32 32 x 3 16 phillips head screws supplied into the threaded holes in the adapter assembly Figure 20A 9 LIGHT KIT ADAPTER ASSEMBLY JUMPER ASSEMBLY SETSCREW COLLAR Figure 1...

Page 10: ...e 5 Separate untwist and unkink the three black white and blue motor wires then route the wires through the downrod 6 Using wiring connectors supplied connect the yellow uplight lead to the yellow wire from the downrod Figure 3B Fold the yellow wire into the slot in the motor coupling slide the downrod down the wires and seat the downrod in the motor coupling 7 Align the clevis pin holes in the do...

Page 11: ...HOUSING CANDELABRA BASE LAMP SOCKET Figure 6B DOWNROD PIN HANGER BALL CEILING COVER Figure 5B IMPORTANT A If you have installed an 18 or longer downrod and are planning to install the decorative support rods assembly proceed to INSTALLATION OF DECORATIVE SUPPORT RODS ASSEMBLY on page 14 After you have installed the decorative support rods assembly continue with the following installation procedure...

Page 12: ...hreaded studs and turn until studs protrude through the holes in the ceiling cover Figure 11B 18 Secure the ceiling cover in place by installing two lockwashers and two knurled knobs supplied Figure 11B Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod 19 Use three 10 32 x 3 8 pan head screws and fla...

Page 13: ...Figure 15B Connect the white wire from the plate assembly to the white wire form the motor shaft using a wire connector supplied NOTE When installing the light kit plate assembly position the wires and wire connectors in the raised center portion of the plate assembly Do not pinch wires between the light kit plate assembly and the adapter assembly 25 Secure the light kit plate assembly to the ligh...

Page 14: ...od support assembly and loosely engage the rod hook with one of the rings on the support assembly Figure 3 Then tighten the setscrew using the 5 64 setscrew 5 Engage the other two support rods in the same manner as above Loosen the setscrew and raise the rod support assembly until the support rods are taut and in line with the downrod Figure 4 Then securely tighten the setscrew using the 5 64 hex ...

Page 15: ...ire connections in the switch housing wire connections in the switch housing 2 Fan sounds noisy 1 Blades not attached to fan 1 Attach blades to fan before operating 2 Support rods loose 2 Tighten the barrels of the rod assemblies 3 Screws securing fan blade flanges to motor hub 3 Check to make sure the screws which attach are loose the fan flanges to the motor hub are tight WARNING Make sure main ...

Page 16: ...er Motor 761621 3 761621 17 761621 21 761621 23 761621 17 761621 21 24 Screw 8 Washerhead 4 25 Capacitor 9 mfd 762117 762117 762117 762117 762117 762117 26 Motor 762304 762304 762304 762304 762304 762304 27 Hub Motor 760601 760601 760601 760601 760601 760601 28 Flange Set Full set for one fan 762105 762105 1 762105 2 762105 3 762105 1 762105 2 29 Adapter Assembly Light Kit 762094 762094 762094 762...

Reviews: