background image

Part No. F40BP73180000

Form No. BP7318

U.L. Model No.: CF759

READ AND SAVE THESE INSTRUCTIONS

Model No.

CF759AB03
CF759AW03
CF759BS03
CF759OB03
CF759ORB03
CF759WB03
CF759WW03

DESIGNER REMOTE

Net Weight:  

21.1

Lbs.

Series Ceiling Fan

Owner's Manual

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.

What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for
one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE,
MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.

What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of
the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price
of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR
REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO.

How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson

Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service
center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.

What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages
as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if
this product does not work properly.

How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Summary of Contents for Designer Remote CF759AB03

Page 1: ...o return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage W...

Page 2: ...e not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 The fan must be installed on a level ceiling ...

Page 3: ...re provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembly your ceiling fan refer to section on proper method of wiring your fan page 7 If you feel you do not have enough wiring knowledge or experi ence have your fan installed by a licen...

Page 4: ...age door openers car alarms or security systems To remedy this situation simply change the combination code in your transmitter and receiver Preset Memory Feature Your Emerson remote control receiver is equipped with a preset memory feature If the electrical supply to the receiver is controlled through a wall switch when the switch is turned off the control will remember the light intensities and ...

Page 5: ... clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin ...

Page 6: ...al codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING WARNING WARNING NOTE Remove and discard the five shipping spacers and screws from the motor hub 11 Loosely attach one blade assembly to the motor hub using two M6 x 14 captive screws with lock washers Figure 9 Make sure the screws are NOT tightened Repeat this procedure for other four b...

Page 7: ...he outlet box is installed so that the mounting surface the bottom of the outlet box is level The receiver will be damaged resulting in an inoperable fan and a possible electrical fire Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall Failu...

Page 8: ...After connecting the wires spread them apart so that the green and white wires are on one side of the outlet box and the black wire is on the other side Make sure that black antenna wire sits on top of the receiver unit OUTLET BOX BLACK SUPPLY WIRE BLACK WHITE RECEIVER WIRE BLACK FAN WIRE BLUE FAN WIRE BLUE RECEIVER WIRE ORANGE FAN WIRE YELLOW RECEIVER WIRE CEILING COVER WHITE RECEIVER WIRE WHITE ...

Page 9: ...e electricity at the wall switch before installing or removing light bulbs on the ceiling fan or light fixture Figure 17 Operation IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your remote control has full control of your fan and lights Figure 17 NOTE Prior to operation of the down light from the remote control make s...

Page 10: ... loose the fan flanges to the motor hub are tight 4 Wire connectors inside cup assembly 4 Check to make sure wire connectors in cup rattling assembly are not rattling against each other or against the interior wall of the cup assembly WARNING Make sure main power is turned OFF 5 Screws holding blades to flanges 5 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose...

Page 11: ...11 21 6 5 20 8 9 16 13 4 1 2 3 12 11 18 10 15 14 17 7 19 Repair Parts ...

Page 12: ...Screw M5 x 6 16 9 Washer Blade 16 10 Threaded Stud 2 11 Lockwasher 2 12 Knurled Knob 2 13 Canopy Ceiling 761620 761620 33 761620 3 761620 9 761620 25 761620 26 761620 29 14 Harness Reversing 763159 763159 763159 763159 763159 763159 763159 15 Switch Housing Assembly 763158 WW 763158 ORB 763158 AB 763158 OB 763158 BS 763158 WB 763158 AW 16 Cover Coupling 762463 15 762463 16 762463 4 762463 762463 8...

Reviews: