AC Power  
For 

Business-Critical Continuity

Liebert Nfinity

®

A Powerful UPS Solution For Small To Medium Data Centers

Summary of Contents for Liebert Nfinity 12-20kVA

Page 1: ...AC Power For Business Critical Continuity Liebert Nfinity A Powerful UPS Solution For Small To Medium Data Centers ...

Page 2: ...ts shrink in size capacity and criticality are increasing Powering all of this equipment is no small task That s why Liebert has developed a power protection solution that can expand easily as your needs grow Putting It All Together The Liebert Nfinity UPS System The Liebert Nfinity power system is a scalable UPS utilizing fault tolerant technology in two scalable models 4 to 16 kVA and 12 to 20 k...

Page 3: ...ct efficient design allows you to pack more power and battery capability into a much smaller sized unit so it takes up less of your valuable floor space Higher Availability And Flexibility Start With Higher Intelligence The Liebert Nfinity is a true on line double conversion UPS that delivers 100 power conditioning zero transfer time to battery no change in output voltage and better transient supp...

Page 4: ...r needs Your Liebert Nfinity UPS can be ordered in dozens of different power and battery capacities and then upgraded at any later time as needs change Using an 8 Bay 16 kVA frame Liebert Nfinity provides capacities up to 16 kVA in a non redundant mode and up to 12 kVA in an N 1 redundant mode with an incredibly small footprint only 20 W x 28 D x 41 H The 12 bay 16 kVA frame provides capacities up...

Page 5: ...Shipped as a complete fully tested system ready for final connection Hot swappable modules allow installation or replacement of power battery control and display modules without shutting down or compromising power to the load Redundant components at critical points of UPS operation Maintenance performed without shutdown Intelligent fault tolerant design enables the power battery and control module...

Page 6: ...nsive range of controls and operating information as well as communications capabilities User Interface Control Panel The user interface is the main source of communication between the Liebert Nfinity UPS and the user It features an easy to read LCD display and LED mimic diagram The control panel informs the user of the status of the UPS including the power and battery modules and allows you to co...

Page 7: ...work provides immediate two way radio access to our factory trained customer engineers through our wireless communication system Exclusive Guaranteed Four Hour Response Time We can guarantee a four hour response time from the time your call is received at our CRC until a Liebert Customer Engineer arrives on site Applicable in U S and Canada Distance limitations apply Preventive Maintenance Prevent...

Page 8: ...rt and the Liebert logo are registered trademarks of the Liebert Corporation SL 23900 R03 07 Printed in USA Ensuring The High Availability Of Mission Critical Data And Applications Scalable 12 20 kVA Scalable 4 16 kVA Specifications General Environmental Units Unit Rating kVA 4 8 12 16 20 kW 2 8 5 6 8 4 11 2 14 Conducted and Radiated EMC Levels FCC Part 15 Class A Compliant Safety Standards UL 177...