Summary of Contents for MEDIA AIR CLEANER ACM1000M-XXX

Page 1: ...CM2000M XXX OWNERS MANUAL Installation Operation Maintenance White Rodgers is a division of Emerson Electric Co www white rodgers com PART NO 37 7001A 0922 Please read and familiarize yourself with the contents of this manual before installing operating or performing maintenance on the unit ...

Page 2: ...1 Read the Owners Manual and the Rules for Safe Operation carefully Failure to follow these rules and instructions could cause a malfunction of filter or unsatisfactory service 2 Follow a regular service and maintenance schedule for efficient operation Installation of this unit must comply with local electric codes or other applicable codes Review and understand local codes prior to installation W...

Page 3: ...r building DIRTY AIR IN 4 FILTER FILTERED AIR OUT CONSTRUCTION OF THE AIR FILTER COMPARTMENT Not only is your air filter compartment easy to install it is also easy to maintain Its basic components and their functions are as follows See Figure 2 Air Filter Cabinet mounts to existing duct work and houses the filters 4 Filter collects dust dirt and other particles SCREW AIR FILTER CABINET LATCH DOOR...

Page 4: ...ORCED AIR SYSTEM ON THE AIR ENTERING SIDE OF FURNACE NOT TO EXCEED 20 DUCTWORK AIR FLOW AIR CLEANER FURNACE Figure 3 Model NO A B C CFM RATING LENGTH HEIGHT WIDTH ACM1000M XXX 19 13 16 18 5 16 5 7 16 600 TO 1200 ACM1400M XXX 24 13 16 18 5 16 5 7 16 1000 TO 1600 ACM1600M XXX 19 13 16 22 5 16 5 7 16 1200 TO 1800 ACM2000M XXX 24 13 16 22 5 16 5 7 16 1800 TO 2200 C B A Figure 4 3 The air filter is not...

Page 5: ...ine inches for mounting the air filter shorten the lateral trunk or attach an offset fitting to the elbow Figure 10 HORIZONTAL FURNACE Filter is mounted vertically in the return duct near furnace Figure 5 BASEMENT FURNACE LOWBOY Filter is mounted horizontally in return plenum just above furnace Figure 6 COUNTERFLOW FURNACE Filter is mounted horizontally in return duct or plenum just above furnace ...

Page 6: ...rtment Note the use of the sheet metal turning vanes inside the elbow to improve air distribution Figure 13 Transition Fittings If the air duct does not fit the compartment opening a transition fitting should be used Gradual transitions are preferred for greatest efficiency Not more than four inches per linear foot approximately 20 angle should be allowed Figure 3 5 Connect the vertical duct secti...

Page 7: ...7 NOTES ...

Page 8: ...www white rodgers com White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co ...