PENBERTHY 

MODEL MGS-314 SERIES AND MGS-314D SERIES LEVEL CONTROL SWITCH

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Before installation, these instructions must be read carefully and understood.

Emerson.com/FinalControl

© 2019 Emerson. All Rights Reserved.

VCIOM-03387-EN 20/06

PRODUCT WARRANTY

Emerson warrants its Penberthy products 
as designed and manufactured to be free of 
defects in material and workmanship for a 
period of one year after the date of installation 
or eighteen months after date of manufacture, 
whichever is earliest. Emerson will, at its 
option, replace or repair any products which 
fail during the warranty period due to defective 
material or workmanship.

Prior to submitting any claim for warranty 
service, the owner must submit proof of 
purchase to Emerson and obtain written 
authorization to return the product. Thereafter, 
the product shall be returned to Emerson, with 
freight prepaid.

This warranty shall not apply if the product has 
been disassembled, tampered with, repaired 
or altered outside of the Emerson factory, or 
if it has been subjected to misuse, neglect 
or accident.

Emerson's responsibility hereunder is 
limited to repairing or replacing the product 
at its expense. Emerson shall not be liable 
for loss, damage, or expenses directly or 
indirectly related to the installation or use 
of its products, or from any other cause or 
for consequential damages. It is expressly 
understood that Emerson is not responsible 
for damage or injury caused to other products, 
building, property or persons, by reason of the 
installation or use of its products. 

1 INTRODUCTION

The instructions in this manual pertain to 
the Penberthy Model MGS-314 or MGS-314D 
magnetic level meter switch. 
The Model MGS-314/314D Series magnetic 
level meter switch is designed to detect the 
passage of the float in a MULTIVIEW™ magnetic 
liquid level meter, at a specific location. The 
switch consists of a snap-action switch and 
a magnetic actuation assembly encased 
in a watertight (Type 4) or explosion-proof 
(Type 7) enclosure. 

This is Emerson's sole warranty and in lieu of 
all other warranties, expressed or implied which 
are hereby excluded, including in particular all 
warranties of merchantability or fitness for a 
particular purpose.

This document and the warranty contained 
herein may not be modified and no other 
warranty, expressed or implied, shall be made 
by or on behalf of Emerson unless modified or 
made in writing and signed by the company's 
president or a vice president.

TABLE OF CONTENTS

Product warranty ................................................ 1

1 Introduction ............................................. 1
2 Specifications/Approvals ......................... 2

2.1 Enclosure ..................................................... 2
2.2 Switch ........................................................... 2
2.3 Approvals ...................................................... 2

3  Theory of Operation ................................. 2
4 Installation ............................................... 2

4.1 Unpacking..................................................... 2
4.2  Mounting the switch .................................... 3
4.3  Wiring connection ........................................ 3

5 Set-up ...................................................... 4

5.1  Initial test ...................................................... 4

6  Pump-Control Set-up .............................. 4

6.1  Interval relay wiring ..................................... 4

7 Troubleshooting ...................................... 4

7.1 Introduction .................................................. 4
7.2  Switch test .................................................... 4
7.3  Actuation test ............................................... 4

8  Telephone Assistance .............................. 5
9   Model  KFA5-SR2-Ex2.W.IR 

Interval Relay .......................................... 9

9.1 Operation ...................................................... 9
9.2  Typical applications ..................................... 9
9.3  Connection diagram .................................... 9

Tables and Figures

Figure 1 - MGS-314 Series ................................ 3
Figure 2 - MGS-314D Series  ............................. 3
Figure 3 -  Control drawing CSA approved 

explosion-proof for 
MGS-314/314D (7E741-009) ............. 5

Figure 4 -  Control drawing CSA approved 

intrinsically safe for 
MGS-314/314D (7E742-009) ............. 6

Figure 5 -  Control drawing ATEX/IECEx  

certified explosion-proof for 
MGS-314/314D (7E741-010) ............. 7

Figure 6 -  Control drawing ATEX/IECEx  

certified intrinsically safe for 
MGS-314/314D (7E742-010) ............. 8

Figure 7 - Application 1-Pump-up diagram ..... 9
Figure 8 -  Application 2- 

Pump-down diagram ........................ 9

Figure 9 - Connection diagram ......................... 9

Summary of Contents for Penberthy MGS-314 Series

Page 1: ...gnetic level meter switch The Model MGS 314 314D Series magnetic level meter switch is designed to detect the passage of the float in a MULTIVIEW magnetic liquid level meter at a specific location The switch consists of a snap action switch and a magnetic actuation assembly encased in a watertight Type 4 or explosion proof Type 7 enclosure This is Emerson s sole warranty and in lieu of all other w...

Page 2: ...trol drawing 7E741 010 Figure 5 Must use suitable certified conduit seal ATEX IECEx Certified Intrinsically safe for Ex ia IIC T6 Ga When installed in accordance with control drawing 7E742 010 Figure 6 3 THEORY OF OPERATION While reading the theory of operation refer to Figure 1 MGS 314 Series or Figure 2 MGS 314D Series for the location of the components The description is based on a side view Wi...

Page 3: ... a conduit seal with a drain or a drip loop to prevent condensate from entering the housing Condensate can cause electrical shorts The switch housing has a NPT F connection for the wiring conduit 2 We recommend attaching an aluminum condulet via a 300 Series stainless steel nipple to the conduit opening of the switch housing This will give you an accessible point to terminate the control wires DO ...

Page 4: ...witch Closed Open NA NA NA MGS 314D Series Toggle at position A liquid level below switch Common for blue and white Common for orange and violet Closed Open Open Closed Toggle at position B liquid level above switch Open Closed Closed Open 7 TROUBLESHOOTING 7 1 Introduction Your Penberthy magnetic level meter switch is designed to give you years of unattended service However failure of electrical ...

Page 5: ...thorization R A number from your authorized Penberthy distributor prior to returning your unit Failure to do so will result in the unit being returned to you without being tested and freight collect To obtain an R A number collect the following information Reason for return Person to contact at your company Ship to address There will be a minimum charge applied for evaluation of non warranty units...

Page 6: ...Isc 150mA Ca Cleads La Lleads One multiple channel intrinsic safety barrier must be used The barrier parameters must meet the following requirements Vt 40V or It 150mA Ca Cleads La Lleads Installation shall conform to the manufacturer s instructions supplied with the intrinsic safety barrier as well as the National Electric Code and ANSI ISA RP 12 6 or CSA C22 Installation of Intrinsically Safe In...

Page 7: ... ATEX IECEx CERTIFIED EXPLOSION PROOF FOR MGS 314 314D 7E741 010 HAZARDOUS AREA EX d IIB Models MGS 314 A MGS 314D A MGS 314L A A flame path seal off shall be installed directly to threaded entry of enclosure Wiring to be in accordance with National Electric Code NEC pertinent parts of the 500 series of Article 5 or local codes as applicable NON HAZARDOUS AREA ...

Page 8: ...er parameters must meet the following requirements Vt 40V or It 150mA Ca Cleads La Lleads Installation shall conform to the manufacturer s instructions supplied with the intrinsic safety barrier as well as the National Electric Code and ANSI ISA RP 12 6 or CSA C22 Installation of Intrinsically Safe Instrument Systems in Hazardous classified Locations Maximum non hazardous area voltage must not exc...

Page 9: ...sically Safe Input PENBERTHY MODEL MGS 314 SERIES AND MGS 314D SERIES LEVEL CONTROL SWITCH INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS APPENDIX B Figure 9 CONNECTION DIAGRAM MGS 314 R1 10 KΩ 5 R1 10 KΩ 5 R2 1 8 7 9 11 10 12 14 15 KFA5 SR2 Ex2 W IR 4 2 5 3 6 R2 1 KΩ 1 KΩ MGS 314 Output 1 Output 2 Suppy 120 Vac 9 MODEL KFA5 SR2 Ex2 W IR INTERVAL RELAY 9 1 Operation Mode condition Lead breaka...

Reviews: