background image

                       www.controltechniques.com

Remote Keypad

Digistart CS

0477-0011-01

User Guide

Summary of Contents for UM380

Page 1: ...www controltechniques com Remote Keypad Digistart CS 0477 0011 01 User Guide ...

Page 2: ...this guide are believed to be correct at the time of printing In the interests of commitment to a policy of continuous development and improvement the manufacturer reserves the right to change the specification of the product or its performance or the content of the guide without notice All rights reserved No parts of this guide may be reproduced or transmitted in any form or by any means electric...

Page 3: ... com Contents 1 Introduction 4 2 Installation 4 2 1 Mechanical installation 4 2 2 Connection 6 3 Operation 7 3 1 Operation 7 3 2 Trip codes 7 4 4 20 mA Analog Output 8 4 1 Overview 8 4 2 Calibration 8 4 3 Programming 8 5 Troubleshooting 9 6 Specifications 9 ...

Page 4: ... control supply power is applied to both devices For basic operation no parameter adjustments are required on the Remote Keypad or the soft starter In order to use the Remote Keypad s 4 20 mA analog output to monitor motor current follow the instructions in the section 4 20 mA Analog Output on page 8 WARNING Remove mains and control voltage from the soft starter before attaching or removing access...

Page 5: ...es com Figure 2 2 Mounting 1 2 4 3 Fasteners x4 Mounting bracket Universal panel cutout 92 mm x 92 mm Remote Keypad 2 1 3 Dimensions Figure 2 3 Unit dimensions 120 4 72 37 5 1 48 7 0 0 28 AMPS CODE TEMP START RUN TRIP RS485 START STOP RESET DATA PROG mm in ...

Page 6: ...al port Remote Keypad B10 B11 4 20 mA analog output motor current B1 B2 B3 RS485 connection to starter module B6 B7 B8 RS485 connection to network 1 2 power supply 18 to 30 Vac dc For the Remote Keypad to accept serial commands a link must be fitted across terminals CSL DI2 on Digistart CS starters 2 2 1 Grounding and shielding Twisted pair data cable with earth shield is recommended The cable shi...

Page 7: ...eypad and the starter is healthy RS485 FLASHING communication between the Remote Keypad and the starter has been lost Control buttons Start Starts the motor Stop Stops the motor 1 Reset Resets the starter 1 Data Prog Selects the data type to be shown on the display motor current or motor temperature or accesses Programming Mode 1 Simultaneously pressing the STOP and RESET buttons initiates a quick...

Page 8: ...de hold down the Data Prog pushbutton for four seconds The default value of the first parameter will be displayed 2 Use the Data Prog pushbutton to advance to the next parameter 3 Use the Stop and Reset pushbuttons to adjust parameter values Programming Mode closes when the Data Prog pushbutton is pressed after Pr 9 NOTE There is a 20 second timeout when the Remote Keypad is in Programming Mode Pr...

Page 9: ...er If connected to a Digistart CS check that terminals CSL DI2 on the starter are linked Pr 8 on the Remote Keypad must be set to 0 or 1 6 Specifications Enclosure Front Panel Height 120 mm Front Panel Width 120 mm Inside Panel Depth when mounted 30 mm max Panel Cutout 92 mm2 Weight 450 g Power Suply Voltage 18 30 Vdc Vac 50 60 Hz Consumption 100 mA max steady state Connection Terminals 1 2 2 pole...

Reviews: