background image

Page 1

INSTALLATION INSTRUCTIONS

AND OWNER’S MANUAL

BIRCH LOGS

WARNING

FIRE OR EXPLOSION HAZARD

If the information in these instructions is 

not followed exactly, a fire or explosion may 

result causing property damage, personal 

injury or loss of life. 

—  Do not store or use gasoline or other 

flammable vapors and liquids in the 

vicinity of this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; 

do not use any phone in your building.

•  Leave the building immediately.

•  Immediately call your gas supplier 

from a neighbor’s phone. Follow     

the gas supplier’s instructions.

•  If you cannot reach your gas  

supplier, call the fire department.

—  Installation and service must be 

performed by a qualified installer, 

service agency or the gas supplier.

INSTALLER: 

Leave this manual with the appliance.

CONSUMER: 

Retain this manual for future reference.

Log sets comply with ANSI Z21.11.2 Unvented 

Heaters  and  also  comply  with  ANSI  Z21.60 

Decorative Vented Appliances for Solid Fuel 

Burning Fireplaces. State or local codes may 

only allow operation of log sets in a vented 

configuration. Check your state or local codes.

 �

WARNING

If  not  installed,  operated  and  maintained 

in  accordance with the manufacturer's 

instructions, this product could expose you 

to substances in fuel or from fuel combustion 

which can cause death or serious illness.

Please See Our Website For Log Assembly Videos.

LOG SET FOR 

UNVENTED 

GAS LOG HEATER OR VENTED 

DECORATIVE APPLIANCE

MODELS:     

LS18CB-1

LS24CB-1

LS30CB-1

GAS-FIRED

LS24CB 

SHOWN

Summary of Contents for LS18CB-1

Page 1: ... call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Log sets comply with ANSI Z21 11 2 Unvented Heaters and also comply with ANSI Z21 60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces State or local codes may on...

Page 2: ...rements for Canada 4 LS 18 24 30 CB Log Sets 5 Log Identification LS18CB 6 Log Placement LS18CB 7 14 Log Identification LS24CB 15 Log Identification LS30CB 16 Log Placement LS 24 30 CB 17 24 Ember Placement LS 18 24 30 CB 25 Appliance Service History 26 Master Parts Distributor List 27 How To Order Repair Parts 27 ...

Page 3: ...ation Properly installed and properly maintained log sets do not deposit soot on the logs If users see soot on a log they should call for service Do not continue to operate the log set Sunken Fireplace If installing this unit into a sunken fireplace raise the floor to ensure adequate airflow and guard against sooting Raise fireplace floor using a non combustible material which is secure Glass Door...

Page 4: ...ce Check for an open flue and adequate combustion air into the room A damper clamp must be installed on the firebox damper to maintain an open flue vent condi tion Refer to fireplace owners manual INSTALLING DAMPER CLAMP section 4 Young children must be carefully supervised when they are in the same room as an operating vent free burner Do not place stockings clothing or any flammable ma terial ab...

Page 5: ...41097 0 0120 Page 5 LS 18 24 30 CB LOG SETS LS24CB LOG SET LS30CB LOG SET LS18CB LOG SET ...

Page 6: ... 6 PART NUMBER DESCRIPTION TOP VIEW FRONT VIEW R12811 Rear Left Log A R12812 Rear Right Log B R12813 Rear Right Log C R12814 Front Left Log D R12815 Left Branch Log E R12816 Right Branch Log F LOG IDENTIFICATION LS18CB ...

Page 7: ...nvented gas burner assembly WARNING This appliance is equipped for natural or propane gas Field conversion is not permitted Apply glowing embers per the ember placement section of this manual on page 30 Replace glowing embers with appropriate part number from the table below from Empire Comfort Systems Inc Application of excess glowing embers may adversely affect perfor mance of the heater WARNING...

Page 8: ...41097 0 0120 Page 8 1 Place Log A onto left rear pin on rear log support LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 9: ...41097 0 0120 Page 9 2 Place Log B onto two 2 right front pins on burner pan LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 10: ...41097 0 0120 Page 10 3 Place Log C onto right rear pin on rear log support LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 11: ...41097 0 0120 Page 11 4 Place Log D onto two 2 left front pins on burner pan LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 12: ...41097 0 0120 Page 12 5 Place Log E on top of the pin located on Log A Log E should rest on top of the left side of Log D LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 13: ...41097 0 0120 Page 13 6 Place Log F on top of the pin located on Log C Log F should rest on top of the left side of Log B and the right side of Log D LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 14: ...41097 0 0120 Page 14 7 Log placement is complete LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 15: ...15 PART NUMBER DESCRIPTION TOP VIEW FRONT VIEW R12817 Rear Left Log A R12818 Front Right Log B R12819 Rear Right Log C R12820 Front Left Log D R12821 Left Branch Log E R12822 Right Branch Log F LOG IDENTIFICATION LS24CB ...

Page 16: ...16 PART NUMBER DESCRIPTION TOP VIEW FRONT VIEW R12823 Rear Left Log A R12824 Front Right Log B R12825 Rear Right Log C R12826 Front Left Log D R12827 Left Branch Log E R12828 Right Branch Log F LOG IDENTIFICATION LS30CB ...

Page 17: ... set is installed onto an unvented gas burner assembly WARNING This appliance is equipped for natural or propane gas Field conversion is not permitted Apply glowing embers per the ember placement section of this manual on page 30 Replace glowing embers with appropriate part number from the table below from Empire Comfort Systems Inc Application of excess glowing embers may adversely affect perfor ...

Page 18: ...41097 0 0120 Page 18 LOG PLACEMENT LS 24 30 CB CONT D 1 Place Log A onto left rear pin on rear log support FRONT VIEW TOP VIEW ...

Page 19: ...41097 0 0120 Page 19 FRONT VIEW TOP VIEW LOG PLACEMENT LS 24 30 CB CONT D 2 Place Log B onto two 2 right front pins on burner pan ...

Page 20: ...41097 0 0120 Page 20 LOG PLACEMENT LS 24 30 CB CONT D 3 Place Log C onto right rear pin on rear log support FRONT VIEW TOP VIEW ...

Page 21: ...41097 0 0120 Page 21 LOG PLACEMENT LS 24 30 CB CONT D 4 Place Log D onto two 2 left front pins on burner pan FRONT VIEW TOP VIEW ...

Page 22: ...41097 0 0120 Page 22 LOG PLACEMENT LS 24 30 CB CONT D 5 Place Log E on top of the pin located on Log A Log E should rest on top of the left side of Log D FRONT VIEW TOP VIEW ...

Page 23: ...97 0 0120 Page 23 LOG PLACEMENT LS 24 30 CB CONT D 6 Place Log F on top of the white pin located on Log C Log F should rest on top of the left side of Log B and the right side of Log D FRONT VIEW TOP VIEW ...

Page 24: ...41097 0 0120 Page 24 LOG PLACEMENT LS 24 30 CB CONT D 7 Log placement is complete FRONT VIEW TOP VIEW ...

Page 25: ...41097 0 0120 Page 25 EMBER PLACEMENT LS 18 24 30 cb Do not cover any large rear ports with glowing embers Do not cover any large front ports with glowing embers Area for glowing embers ...

Page 26: ...41097 0 0120 Page 26 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes ...

Page 27: ...ase and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be ...

Page 28: ...www empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer ...