ETM1411
ENDA
DIGITAL TIMER
STOP
START
OUT
MIN
HOUR
TECHNICAL SPECIFICATIONS
Supply
230V AC +10 -20 , 50/60Hz or 24
%
%
V AC/DC 10%, 50/60Hz or 12V AC/DC 10%, 50/60Hz
±
±
Power consumption
Max 4VA
2.5mm² screw-terminal connections
±
1%
4 digits, 12.5mm, 7 segment yellow LED
Wiring
Scale
Sensitivity
Time Accuracy
Indicator
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
The device is designed to operate in controlled electromagnetic environment)
EN 61010-1: 2001 (
)
pollution degree 2, overvoltage category II
START INPUT
Input type
Control with mechanical contact.
Min. = 100ms
On and Off times for input
pulses
OUTPUT
ELEKTRÝKSEL ÖZELLÝKLER
OUT
Relay: 250V AC, 8A (
), NO+NC
for resistive load
Mechanical 30.000.000 operation; Electrical 100.000 operation
Life expectancy for relay
ENVIRONMENTAL CONDITIONS
Height
2000m
Max.
80% up to 31°C decreasing linearly 50% at 40°C.
Ambient/storage temperature
Max. Relative humidity
0 ... +50°C/-25 ... +70°C (with no icing)
Selectable 99:59 min. or hour.
1 sec.
Rated pollution degree
According to EN 60529 Front panel : IP65
Rear panel : IP20
Do not use the device in locations subject to corrosive and flammable gases.
HOUSING
Housing type
Suitable for flush-panel mounting
Dimensions
W77xH3
5
xD7
1
mm
Weight
Approx. 198g (after packing)
Enclosure material
Self extinguishing plastics
Thank you for choosing ENDA ETM1411 digital timer.
* 3
5
x 77mm sized.
* Single contact output for timing control.
* External start input.
* Display can be adjusted to show min. or sec.
* Scale ;
0:01 .... 99:59 mins.
0:01 .... 99:59 hrs.
* Decrease and increace step of time can be adjusted.
* Start and stop possibility by front panel.
* 16 different warning tones.
* Upper and lower limits of the setpoint can be
adjusted.
* CE marked according to European Norms.
Connection Diagram
ENDA ETM1411 is intended for installation in control panels. Make sure that the device is
used only for intended purpose. The shielding must be grounded on the instrument side.
During an installation, all of the cables that are connected to the device must be free of
electrical power. The device must be protected against inadmissible humidity, vibrations,
severe soiling and make sure that the operation temperature is not exceeded. All input and
output lines that are not connected to the supply network must be laid out as shielded and
twisted cables. These cables should not be close to the power cables or components. The
installation and electrical connections must be carried out by a qualified staff and must be
according to the relevant locally applicable regulations.
1/2
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
ETM
1
411-E-0
5-R
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
While cleaning the device, solvents (thinner, benzine, acid etc.) or
corrosive materials
must not be used.
7
8
SUPPLY:
NOTE :
184-253V AC
50/60Hz 4VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected.
1)
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of
the relevant instrument and it should be easily accessible
by the operator.
Mains supply cords shall meet the requirements of
ENDA
ETM
1
411 DIGITAL TIMER
Please read this document carefully before using this product. The guarantee will be
invalidated if the device is damaged by not following instructions detailed in the
manual. The company shall not be responsible for any damage or losses however
caused, which may be experienced as a result of the installation or use of this product.
Order Code :
ETM
1
411-
1
Supply Voltage
230VAC...230V AC
24............24V AC/DC
12............12V AC/DC
1-
2
4
V
A
C
/D
C
1
0
%
5
0
/6
0
H
z
4
V
A
±
SN: XXXXXXXXX
ETM14
11
-24
DIGITAL TIMER
ENDA
INDUSTRIAL ELECTRONICS
O
U
T
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9 10 11 12
START
SN: XXXXXXXXX
ETM14
11
-230VAC
DIGITAL TIMER
ENDA
INDUSTRIAL ELECTRONICS
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
4
V
A
O
U
T
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9 10 11 12
START
1
2
V
A
C
/D
C
1
0
%
5
0
/6
0
H
z
4
V
A
±
SN: XXXXXXXXX
ETM14
11
-12
DIGITAL TIMER
ENDA
INDUSTRIAL ELECTRONICS
O
U
T
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9 10 11 12
START
Panel cut-out
Dimensions
Note :
1) Panel thickness
should be maximum
7 mm.
2)
If there is no 60mm
free space at the back
side of the device, it
would be difficult to
remove it from the
P
anel.
71mm
2
9
m
m
Flush mounting
clamp
For removing mounting clamps:
Push the flush-mounting
clamp in
direction
1
as
shown
in the figure below. Then, pull
out the clamp in direction
2.
1
3
5
m
m
77mm
SET
SET
ETM1411
ENDA
DIGITAL TIMER
STOP
START
OUT
MIN
HOUR
SN
: X
XX
XX
XX
XX
ET
M1
4
11
-2
30
VA
C
DIG
IT
AL
T
IM
ER
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
2
3
0
V
A
C
+
1
0
%
-2
0
%
5
0
/6
0
H
z
4
V
A
O
U
T
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9
10
11
12
ST
AR
T
Flush mounting
clamp
Depth
Panel
2
71mm
5mm
Rubber
packing