background image

MANUAL

IN CHARGE OF YOUR BATTERIES

www.energicplus.com

BATTERY DISCHARGER AND ANALYSER MPD-1007E

REF 35364672 DISCHARGER MPD-1007E

REF 40799583 DISCHARGER MPD-1007E + BMS 48 V

REF 40799574 DISCHARGER MPD-1007E + BMS 80 V

Summary of Contents for MPD-1007E

Page 1: ...IN CHARGE OF YOUR BATTERIES www energicplus com BATTERY DISCHARGER AND ANALYSER MPD 1007E REF 35364672 DISCHARGER MPD 1007E REF 40799583 DISCHARGER MPD 1007E BMS 48 V REF 40799574 DISCHARGER MPD 1007E BMS 80 V ...

Page 2: ...al working conditions 3 2 Introduction 3 3 Specifications 3 4 Operation 4 4 1 Synchronisation with Replus machines 4 4 2 Stand alone operation 5 4 3 Discharging report 7 4 4 Error alarm messages 7 5 EC certificate 8 Table of contents ...

Page 3: ...ency 50 Hz 60 Hz Phase Single phase SYNCH with Replus regenerators Replus support model REF 100BA3558 REF 100BA3559 REF 100BA3560 Current range 1 A 200 A Protocol interface RS 232 Discharge function support Manual discharge mode Program mode discharge restoration mode Pulse 3 4 PC software support YES wireless communication support use existing Replus operation method BMS Battery monitoring system...

Page 4: ...ow to use input interface Rotate toggle switch menu select Push enter How to use input interface 4 1 1 Setup menu Change the discharge values and other settings like date time and backlight Setup menu display Discharge Change discharge values Date Time Time setup Back Light LCD backlight setup Replus output connector not used in stand alone mode RS 232 D sub port AC input main power on off LCD dis...

Page 5: ...ached The set Limit AH value has been reached Date Time Backlight Menu Description Setting range Default setting Brightness LCDbrightnesssetting 0 100 50 4 1 2 Discharge operation The discharge process commences as soon as the START option is selected The MPD 1007E will discharge according to the voltage current and time set in the setup menu If you need to force shutdown while discharging press t...

Page 6: ...een of the Replus The discharger only needs to be switched on in case you re going to use the discharge mode Wiring diagram When connecting the machines you should use the RS 232 communication cable that is provided Connect the MPD 1007E to the Replus regenerator by plugging the USB cable in the USB port on the back of the Replus regenerator Connect the other end of the cable to the RS 232 port on...

Page 7: ... connection is successful this screen will appear on your MPD 1007E machine D i s c h a r g i n g After starting the discharge this screen will appear to indicate the process has started 4 4 Error alarm messages Cause Internal operating temperature of the MPD 1007E is high Check Make sure the ambient temperature is below 50 C Please check if the cooling fan functions normally Cause The connection ...

Page 8: ... de batería РАЗРЯДНОЕ УСТРОЙСТВО Batterijontlader Indicateur de décharge de batterie battery discharger batterieentladegerät Scaricatore di batterie Descargador de batería РАЗРЯДНОЕ УСТРОЙСТВО ENERGIC PLUS 1007K 1007E 1007H TVH 35364672 dat het zelf het TECHNISCH DOSSIER samenstelt qu il constitue le DOSSIER TECHNIQUE en personne that it draws up the TECHNICAL FILE itself dass er selber die TECHNI...

Page 9: ... EU 2014 35 EU einschließlich nachfolgender Änderungen und Ergänzungen EN61000 6 2 2005 EN61000 6 4 2007 A1 2011 EN61010 1 2010 o la Directiva 2014 30 EU 2014 35 EU y sucesivas modificaciones e integraciones EN61000 6 2 2005 EN61000 6 4 2007 A1 2011 EN61010 1 2010 o la Direttiva 2014 30 EU 2014 35 EU e successive modifiche e integrazioni EN61000 6 2 2005 EN61000 6 4 2007 A1 2011 EN61010 1 2010 o Д...

Page 10: ...10 USER MANUAL MPD 1007E ...

Page 11: ...11 USER MANUAL MPD 1007E ...

Page 12: ...5 8790 Waregem Belgium October 2018 Energic Plus is a registered trademark TVH Group NV Brabantstraat 15 B 8790 Waregem TVH is a supplier of after market spare parts and accessories that are suitable for the maintenance and repair of OEM equipment REF 42404553 09 2018 JS ...