1.0   IMPORTANT RECEIVING 

INSTRUCTIONS

Visually inspect all components for shipping damage.  
Shipping  damage  is 

not 

covered  by  warranty.  If 

shipping damage is found, notify carrier at once. The 
carrier  is  responsible  for  all  repair  and  replacement 
costs resulting from damage in shipment.

SAFETY FIRST

2.0  SAFETY ISSUES

Read 

all 

instructions, 

warnings 

and 

cautions 

carefully.  Follow  all  safety 

precautions  to  avoid  personal  injury  or  property 
damage during system operation. Enerpac cannot be 
responsible for damage or injury resulting from unsafe 
product use, lack of maintenance or incorrect product 
and/or  system  operation.  Contact  Enerpac  when  in 
doubt as to the safety precautions and operations. If 
you  have  never  been  trained  on  high-pressure 
hydraulic  safety,  consult  your  distribution  or  service 
center for a free Enerpac Hydraulic safety course.

Failure  to  comply  with  the  following  cautions  and 
warnings  could  cause  equipment  damage  and 
personal injury.

CAUTION

 is used to indicate correct operating or 

maintenance  procedures  and  practices  to  prevent 
damage  to,  or  destruction  of  equipment  or  other 
property.

WARNING

  indicates  a  potential  danger  that 

requires  correct  procedures  or  practices  to  avoid 
personal injury.

DANGER 

is only used when your action or lack of 

action may cause serious injury or even death.

WARNING:

 

Wear 

proper 

personal 

protective  gear  when  operating  hydraulic 
equipment.

WARNING: 

Stay clear of loads supported 

by hydraulics. A cylinder, when used as a 
load  lifting  device,  should  never  be  used 
as  a  load  holding  device.  After  the  load 

has  been  raised  or  lowered,  it  must  always  be 
blocked mechanically.

WARNING:  USE  ONLY  RIGID  PIECES 
TO  HOLD  LOADS

.  Carefully  select  steel 

or  wood  blocks  that  are  capable  of 

supporting  the  load.  Never  use  a  hydraulic  cylinder 
as  a  shim  or  spacer  in  any  lifting  or  pressing 
application.

DANGER: 

To  avoid  personal  injury 

keep hands and feet away from cylinder 
and workpiece during operation.

WARNING: 

Do  not  exceed  equipment 

ratings.  Never  attempt  to  lift  a  load 
weighing  more  than  the  capacity  of  the 
cylinder.  Overloading  causes  equipment 

failure and possible personal injury. The cylinders are 
designed for a max. pressure of 700 bar [10,000 psi]. 
Do not connect a jack or cylinder to a pump with a 
higher pressure rating.

WARNING:  Never  set  the  relief  valve 
pressure  above  10,500  psi  [725  bar]. 

Serious personal injury could result if this 

maximum  limit  is  exceeded.  Damage  to  pump  and 
components may also occur.

WARNING: 

The 

system 

operating 

pressure  must  not  exceed  the  pressure 
rating  of  the  lowest  rated  component  in 
the system. Install pressure gauges in the 

system  to  monitor  operating  pressure.  It  is  your 
window to what is happening in the system.

Index:

English ............................................................... 1-9
Français ......................................................... 10-18
Deutsch ........................................................  19-27
Italiano ..........................................................  28-36
Español .........................................................  37-45
Nederlands ...................................................  46-54
Portuguese ...................................................  55-63

 ...........................................................  64-71

 .......................................................... 72-79

Finnish ........................................................... 80-88
Norwegian ..................................................... 89-97
Svenska ....................................................... 98-106
Russian ...................................................... 107-115
Greek ......................................................... 116-125

Summary of Contents for Ultima P-18

Page 1: ...ces to avoid personal injury A DANGER is only used when your action or lack of action may cause serious injury or even death WARNING Wear proper personal protective gear when operating hydraulic equipment WARNING Stay clear of loads supported by hydraulics A cylinder when used as a load lifting device should never be used as a load holding device After the load has been raised or lowered it must a...

Page 2: ...nt must only be serviced by a qualified hydraulic technician For repair service contact the Authorized ENERPAC Service Center in your area To protect your warranty use only ENERPAC oil WARNING Immediately replace worn or damaged parts with genuine ENERPAC parts Standard grade parts will break causing personal injury and property damage ENERPAC parts are designed to fit properly and withstand high ...

Page 3: ...for the locations of pump features and major components Refer to Table 2 for descriptions of items A through G A B C D D E Figure 1 Models P 18 and P 39 A B C D D E G Figure 2 Model P 77 A B C D D E F G Figure 3 Models P 80 and P 801 B C D D E A G Figure 4 Model P 84 ...

Page 4: ...n external pressure reducing valve is being used in the circuit connect the tank port of the valve to the return to tank port on the pump Note Cylinders hoses and accessories shown in Figure 5 are sold separately and not included with pump Refer to the Enerpac catalog for a complete description of available components and accessories The exact components required for your system will vary dependin...

Page 5: ... reached the end of its travel Do not apply side force to pump handle IMPORTANT To reduce handle effort at high pressure take short strokes Maximum leverage is obtained in the last 5 degrees of stroke 5 2 Two Stage Flow Models P 77 P 80 P 801 and P 84 Two speed pumps provide two stage flow Under no load the pump operates in the high flow first stage for rapid advance When the load is contacted the...

Page 6: ... 1 Loosen and remove oil fill plug to provide reservoir venting during the following steps 2 Fully close release valve 3 Position pump in the horizontal position at higher elevation than cylinder See Figure 11 4 Position cylinder with the plunger end down up if using pull cylinder 5 Operate pump to fully extend the cylinder retract if using pull cylinder 6 Open release valve to retract cylinder ex...

Page 7: ... result if this maximum limit is exceeded Damage to pump and components may also occur 6 All models except P 84 After the desired setting is obtained turn the release valve counter clockwise to relieve system pressure Check that pressure gauge indicates zero 0 psi bar 7 Model P 84 only After the desired setting is obtained move the valve handle to the N neutral position to relieve system pressure ...

Page 8: ... only the oil fill plug supplied with the pump or a genuine Enerpac replacement plug of identical specifications CAUTION Never attempt to return more oil to the reservoir than it is capable of holding 9 2 Changing the Oil Drain all oil from reservoir and refill with clean Enerpac oil every 12 months If pump is used in dirty environments change the oil more frequently 1 Remove oil fill plug from re...

Page 9: ... to lift more than rated tonnage 6 Remove air according to the instructions in Section 6 0 7 Remove excess oil from reservoir Note If cylinder operates normally when pump oil fill plug is loosened reservoir may be overfilled with oil 8 Check for damage to cylinder Have cylinder serviced by an Enerpac Authorized Service Center 1 Check that all connections are tight and leak free 2 Locate leak s and...

Page 10: ... 7 495 98090 92 sales ru enerpac com Singapore Actuant Asia Pte Ltd 83 Joo Koon Circle Singapore 629109 T 65 68 63 0611 F 65 64 84 5669 Toll Free 1800 363 7722 sales sg enerpac com South Korea Actuant Korea Ltd 3Ba 717 Shihwa Industrial Complex Jungwang Dong Shihung Shi Kyunggi Do Republic of Korea 429 450 T 82 31 434 4506 F 82 31 434 4507 sales kr enerpac com Spain and Portugal ENERPAC SPAIN S L ...