background image

INSTALLATION      NSTRUCTIONS

WARRANTY INFORMATION

This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase. 
Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims 
must be verified and approved by Enerwave, Inc. Warranties from other Enerwave products may vary. This warranty 
is nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from 
misuse, abuse, neglect, alteration, modification, or improper installation.  To the fullest extent permitted by the 
applicable state law, Enerwave shall not be liable to the purchaser or end user customer of Enerwave products for 
direct, indirect, incidental, or consequential damages even if Enerwave has been advised of the possibility of such 
damages.  Enerwave’ total liability under this or any other warranty, express or implied, is limited to repair, 
replacement or refund.  Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or 
any other legal theory.

© 2016 Enerwave Home Automation 

 WWW.ENERWAVEAUTOMATION.COM 

 CA, USA

0210160033-0

6

Model: ZW15SM-PLUS
Wireless Home Automation Control 
ON/OFF Switch

 

with Smart Meter

WARNING: 

Turn the POWER OFF at the circuit breaker before installing the Switch 

Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician performs this installation. Make sure to turn off the circuit breaker or fuse(s) and make 
sure power is off before wiring the device. Exercise extreme caution when using Z-Wave devices to control appliances. Operation of the Z-Wave device may be in a different room than the controlled appliance so an unintentional activation may occur if the wrong button on the remote is pressed. Z-
Wave devices can be automatically powered on by programmed events. Unattended or unintentional operation could result in hazardous conditions. Z-Wave enabled devices should never be used to supply power to, control or monitor medical and/or life support equipment. 

To enable the 3-way 

function install the ZW3K-N in conjunction with the ZW15SM-PLUS. For use with incandescent, halogen, and CFL lights. Use copper wires only.

Connect the BLACK wire on switch to the HOT wire.

Connect the WHITE wire on switch to the NEUTRAL wire.

Connect the Red wire on switch to the LOAD wire.

Connect the GREEN wire on switch to the GROUND wire 
or green GROUND screw on box.

DESCRIPTION

The 

ZW15SM-PLUS

 by itself is a Single Pole switch. Our unique wiring method 

combined with Advanced Z-Wave technology allows for multiple switches (requires 
ZW3K-N) to control a single Load manually at the devices or remotely from a 
computer, smart phone or tablet in Real Time. The ZW15SM-PLUS is fully compatible 
with other Z-Wave devices and it can be added to most Z-Wave compliant controllers. 

FEATURES

Replaces a standard 120VAC, 15Amp wall switch with a technologically advanced 
switch that can be manually controlled at the device or remotely through the Z-Wave 
network. 

 Set scenes, schedule events (Program ON/OFF times like a timer), and even turn 
ON/OFF when a motion or door sensor goes off.

Can be used as a Single Pole switch or 3- Way (Multi-location) with ZW3K-N 
Auxiliary Switch (sold separately).

A blue LED night light can be programmed to come on when the load is ON or OFF.

3 Interchangeable Color Face Plates included (white, light almond, and black).

Compatible with CFL, fluorescent, incandescent, and halogen bulbs.

Measures energy usage of the connected load.

UPGRADING STANDARD SWITCHES TO Z-WAVE

REPLACING EXISTING SWITCHES WITH THE ZW15SM-PLUS

Replacing a standard light switch with a smart Z-Wave switch is a simple way to modernize your home by adding programmable lighting control to your smart 
device. The ZW15SM-PLUS Smart Meter Switch enables you to measure the energy usage of your Lights. When added to a Z-Wave network, the ZW15SM-PLUS 
reports real time data to your gateway or controller. It can also display actual consumption (in W) and the accumulated power used (in kWh) in the user interface 
depending on the Hub. Please refer to your Hub manual for specific instructions on measuring the power.

If you have trouble identifying the 

wires, STOP and consult with an 

Electrician.

WIRING DIRECTIONS

DO NOT REVERSE THE HOT AND TRAVELER WIRES.
DOING SO WILL VOID YOUR WARRANTY AND THE SWITCH WILL SHORT CIRCUIT.

Step 1.

 Identify all your wires. Label the wires or draw a diagram of existing wires. Make sure there is a 

NEUTRAL, HOT, and LOAD wire where the ZW15SM-PLUS will be installed.

Step 2. 

Connect the wires according to the Diagram.

For 3-Way installation, the ZW15SM-PLUS 

requires

 the 

3-Way Control Auxiliary Switch 

ZW3K-N.

standard 

3-Way switch 

WILL NOT WORK

 with the 

ZW15SM-PLUS. Follow the ZW3K-N Instruction Manual 

for 3-Way installation.

REQUIREMENTS

Z-Wave devices require a connection to a compatible hub. Once the device is properly added to 
the hub, it can be managed and customized to your needs. Please visit 
www.enerwaveautomation.com for a list of compatible hubs. NEUTRAL wire is required.

SPECIFICATIONS

Voltage....................................................

........

....................................

........

................ 120VAC, 60Hz

Incandescent........................................

........

......................................

........

..............................1000W

Ballast....................................................

........

...........................................

........

..

...

....................1200VA

Resistive..............................................

........

..............................................

........

..............1800W(15A)

Motor..................................................

........

.......................................................

...........

............... 1/2 HP

Operating Temperature..........

........

....................................................

..

......................... 32-104° F

Z-Wave Frequency......................................

........

............................

.

....

...

.................... 908.42 MHz

Range....................................................

........

.....

...

................................Up to 1

00

 feet line of sight 

................between the Wireless Controller and the closest Z-Wave receiver module.

FCC  COMPLIANCE STATEMENT

FCC Grant of Equipment Authorizations of this device and transmitters installed in this device can be found at FCC website by entering the FCC ID number on the device.

Caution: 

Changes or modifications not expressly approved by the part responsible for compliance could void the user’s right to operate the equipment.  

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this 
device must accept any interference received, including interference that may cause undesired operation of the device. 
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the following measures:

To Replace the Face 

Cover, use a small 

screwdriver to pry off the 

cover

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Electronic 

Ballas

t.............................................................................................................................5A

Reviews: