Q U I C K
I N S T A L L
G U I D E
(Models Q-CONN-3P-10F and Q-CONN-3P-10M)
Install the Enphase Three-Phase
Field Wireable Connectors
Corporate Headquarters Contact Information
Enphase Energy Inc.
47281 Bayside Parkway
Fremont, CA 94538 USA
© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase
logo, Enphase Field Wireable Connector, and other trademarks or
service names are the trademarks of Enphase Energy, Inc. Data
subject to change. Rev02-11-12-2021.
PREPARATION
Check that you have Enphase Field Wireable Q Connectors for three-phase Q Cable
as needed for your installation. Both female and male connectors are sold in packs
of ten:
• Field Wireable Q connector for three-phase (female):
(Q-CONN-3P-10F)
• Field Wireable Q connector for three-phase (male):
(Q-CONN-3P-10M)
Make sure you have the following recommended tools:
• Screwdriver blade width 3.5mm, PH1 Screwdriver
• 30mm wrench
Use Enphase Field Wireable Q Connectors with three-phase Enphase Q Cable or field cable to:
• Easily connect three-phase Q Cables without complex wiring
• Use a mated pair of connectors to end-feed the branch circuit with an AC connection
• Use mated pairs of connectors to connect with a remote part of the array
FEMALE CONNECTOR PARTS
MALE CONNECTOR PARTS
PARTS
*
WARNING
: Risk of equipment failure. Do not mix
male and female connector parts when assem-
bling connectors.
Technical Data
Degree of Protection
IP66/IP68 (2m, 24h)
Nominal Current
(Observe derating, see
graph below)
Conductor cross section IEC/EN61984
6 mm
2
35 A
4 mm
2
32 A
2.5 mm
2
24 A
Nominal Voltage
690 V
Rated Surge Voltage
6 kV
Pollution Degree
3
Operating temperature
-40°C to +110°C
Material
PPE
Enphase Customer Support:
http://enphase.com/global/contact
1. Cable gland
2. Seal
3. Housing
4. Contact carriers
1. Cable gland
2. Seal
3. Housing
4. Contact carriers
1
2
3
4
N
3
4
3
2
1
IEC/EN61984