background image

F I E L D - W I R E A B L E   C O N N E C T O R S

Check that you have Enphase Field Wireable Q Connectors as needed for 
your installation. Both female and male connectors are sold in packs of ten:

•  Field-Wireable Q connector (female): (Q-CONN-10F)
•  Field-Wireable Q connector (male): (Q-CONN-10M) 

Make sure you have the following required tools:

•  Diagonal cutter
•  Wire stripper
•  Crimp tool: Multi-Contact PV-CZM-18100, -19100, or -22100
•  Channel lock pliers or torque wrench
•  Enphase disconnect tool

When to Use Field-Wireable Q Connectors

Use Enphase field-wireable connectors with Enphase Q-Cable or field 
cable to:

•  Easily connect Q cables on the roof without complex wiring
•  Use male connectors to make connections from any Q Aggregator 

open connector

•  Use female connectors to make connections from any Q Cable 

open connector

•  Make a jumper to connect with a remote part of the array: Use 

female to female for cable-to-cable connections, or male to female 
for aggregator-to-cable extensions

•  Use a mated pair of connectors to splice two cut ends of cable

PREPARATION

Enphase 

disconnect 

tool

Safety Instructions

+

DANGER

: Risk of electric shock. Do not use Enphase 

equipment in a manner not specified by the manufacturer. 

Doing so may cause death or injury to persons, or damage 

to equipment.

+

DANGER

: Risk of electric shock. Be aware that installation 

of this equipment includes risk of electric shock. Do not use 

without first removing AC power from the Enphase System. 

Disconnect the power coming from the photovoltaics before 

servicing or installing.

+

DANGER

: Risk of electric shock. Risk of fire. Before making 

any connections verify that the circuit breakers are in the off 

position. Double check all wiring before applying power.

+

DANGER

: Risk of electric shock. Risk of fire. Only use 

electrical system components approved for wet locations, 

including but not limited to conduit fittings.

+

DANGER

: Risk of electric shock. Risk of fire. Only qualified 

personnel should install, troubleshoot, or replace the En-

phase Field Wireable Connector.

+

DANGER

: Risk of electric shock. Improper use of the Field 

Wireable Connector or its components may result in a shock, 

fire or explosion. To reduce these risks, disconnect all wiring 

before attempting any maintenance.

+

DANGER

: Risk of electric shock. Risk of fire. Ensure that all 

AC and DC wiring is correct and that none of the AC wires 

are pinched, shorted, or damaged.

+

DANGER

: Risk of electric shock. Risk of fire. Do not attempt 

to repair or alter the Enphase Field Wireable Connector. 

+

DANGER

: Risk of electric shock. Risk of fire. Make sure 

the conductors are not damaged. If the exposed wires are 

damaged, the system may not function properly.

*

WARNING

: Risk of equipment damage. Enphase male and 

female connectors must only be mated with the matching 

male/female connector.

Safety Symbols

+

DANGER

: This indicates a hazardous situation, which if not 

avoided, will result in death or serious injury.

*

WARNING

: This indicates a situation where failure to 

follow instructions may be a safety hazard or cause 

equipment malfunction. Use extreme caution and follow 

instructions carefully.

;

WARNING

: Risk of burn. Failure to follow instructions may 

result in burn injury.

NOTE

: This indicates information particularly important for 

optimal system operation.

SAFETY

IMPORTANT SAFETY INSTRUCTIONS.  

SAVE THIS INFORMATION.

 

Follow all safety and assembly instructions when installing 

Enphase Field Wireable Connectors. 

Safety Instructions

*

WARNING

: Risk of equipment damage. This product is 

intended for operation in an environment having a maximum 

ambient temperature of 55ºC (131ºF).

*

WARNING

: When installing the cabling, secure any loose 

cable to minimize tripping hazard

*

WARNING

: Before installing or using the Enphase Field 

Wireable Connector, read all instructions and cautionary 

markings in the technical description, on the Enphase Sys-

tem, and on the photovoltaic (PV) equipment.

NOTE

: Using unapproved attachments or accessories may 

result in damage or injury.

NOTE

: When looping the Enphase Q Cable, do not form 

loops smaller than 4.75 inches (12 cm) in diameter.

NOTE

: Perform all electrical installations in accordance with 

all applicable local electrical codes: the Canadian Electri-

cal Code, part 1; the National Electrical Code (NEC); ANSI 

requirements; and NFPA 70.

NOTE

: To ensure optimal reliability and to meet warranty 

requirements, install the Enphase Field Wireable Connectors 

according to the instructions in this guide.

NOTE

: Protection against lightning and resulting voltage 

surge must be in accordance with local standards. 

NOTE

: The connector is considered to be in compliance with 

UL 6703 only when assembled in the manner specified by 

these assembly instructions.

NOTE

: Cable used with Enphase Field Wireable connectors 

must meet the following requirements:

• Min/max outer insulation diameter (including the clear 2nd  

   insulator): 3.45mm / 3.65mm

• Number of conductor strands / size:19 strands of 0.47 mm

• Wire size: 12 AWG

Revision History