background image

Hyperion User Manual 

51164

 

For latest version visit: 

www.enttec.com 

January 19 

ID: 3809208 

Hyperion

 

INTELLIGENT GIGABIT SWITCH

 

 

 

Contents 

Package Contents .................................................................... 2

 

Safety Information .................................................................. 2

 

Initial Setup ............................................................................... 2

 

Out of Box (Factory Settings) ............................................ 2

 

Finding IP Address Using NMU v1.9 ................................. 2

 

Default Login Details .......................................................... 3

 

Physical Dimensions ............................................................... 3

 

Specifications ........................................................................... 4

 

Hyperion Hardware Interface (Front) ................................. 5

 

LED Status .................................................................................. 5

 

Hyperion Hardware Interface (Rear) .................................. 5

 

Application Diagram ............................................................... 6

 

Ethernet Link Pin Out ............................................................. 6

 

Redundancy Link ..................................................................... 7

 

How to Access Web Interface?.............................................. 8

 

Hyperion Web Interface ......................................................... 9

 

Home Page ................................................................................ 9

 

Settings Page .......................................................................... 10

 

Change Password .............................................................. 10

 

Ports Page ................................................................................ 11

 

Link Aggregation .................................................................... 12

 

Administration ........................................................................ 13

 

Restore to factory defaults (web interface) ............... 13

 

Restore to factory defaults (reset button) .................. 14

 

Reboot .................................................................................. 14

 

Backup ..................................................................................14

 

Restore .................................................................................14

 

Firmware Update................................................................ 15

 

Tips and Tricks ........................................................................ 17

 

Hyperion not found by NMU ........................................... 17

 

Unsuccessful Firmware update, causes white page . 17

 

Settings do not Save ......................................................... 17

 

Redundancy Link Doesn’t work

 ...................................... 17

 

Connection Lost ................................................................ 18

 

Device connected to Hyperion, not found ................. 18

 

Device not discovered on reconnection ..................... 18

 

Settings for your Computer .............................................19

 

Steps for Windows 7 ......................................................19

 

Steps for MacOS ............................................................ 20

 

Available Models .................................................................... 21

 

Ordering Information ............................................................ 21

 

Accessories and Recommended Products....................... 21

 

 

Summary of Contents for Hyperion 71025

Page 1: ... Interface 8 Hyperion Web Interface 9 Home Page 9 Settings Page 10 Change Password 10 Ports Page 11 Link Aggregation 12 Administration 13 Restore to factory defaults web interface 13 Restore to factory defaults reset button 14 Reboot 14 Backup 14 Restore 14 Firmware Update 15 Tips and Tricks 17 Hyperion not found by NMU 17 Unsuccessful Firmware update causes white page 17 Settings do not Save 17 R...

Page 2: ... be routed so that they are not likely to be walked on or pinched Initial Setup Out of Box Factory Settings All Hyperion devices come with the following default settings IP 192 168 0 10 Subnet Mask 255 255 255 0 Gateway 0 0 0 0 If multiple Hyperion units are connected to the same network manually change the IP address to avoid any conflicts Finding IP Address Using NMU v1 9 Connect Hyperion direct...

Page 3: ... in the default IP shown on NMU into any browser Log into the device as shown in window below Default Login Details The log in details for the device are as follows Username admin No password leave empty Once logged in set the device with the appropriate network configurations Physical Dimensions ...

Page 4: ...ion Over current Auto recovery Over temperature Latch Short Auto recovery Over voltage Auto recovery MAC Address table limit 8192 Maximum frame length 9216 B Cache 32 Mb Switching Capacity 52 Gbps IGMP support Yes V1 V2 IGMP snooping multicast Yes enabled by default Net Weight 2 5 kg 5 52 lb Gross Weight 2 8 kg 6 18 lb Dimensions without ears L x W x H 445 82 mm x 180 29 mm x 43 20 mm 17 55 in x 7...

Page 5: ...ttec com January 19 ID 3809208 5 Hyperion Hardware Interface Front LED Status Power LED Status LED Operation Green static Amber Device loading firmware Green Static Green Blinking Normal operation Green Static No lit Rebooting Hyperion Hardware Interface Rear ...

Page 6: ...anual 51164 For latest version visit www enttec com January 19 ID 3809208 6 Application Diagram Ethernet Link Pin Out Pin Colour 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown ...

Page 7: ...illiseconds once link failure is detected Notes Redundancy link must be enabled check from Home page for Ports 7 and 8 If Hyperion is restored to factory defaults redundancy link will be disabled for all ports To enable redundancy link for Ports 7 and 8 simply load the Home page once To enable redundancy link for other Ports use Ports page Can only be enabled disabled when Port is not in use not c...

Page 8: ...y modern web browser such as Chrome Firefox Safari or Edge 2 To access the web interface type in the assigned IP address of Hyperion e g 10 10 0 201 3 You will be prompted to login using the following details User name admin Password Please use the password if any set by you By default password is not required so should be empty ...

Page 9: ...rts 4 Administration Home Page Home page shows the followings information Device Name Identify this Hyperion in the network System uptime The time since Hyperion was switched on Number of ports IP address Sub netmask Gateway IP Mac address unique Redundancy Backbone link Ports 7 and 8 only Multicast IGMP Snooping and Query Status should always be enabled Software Hardware Firmware versions ...

Page 10: ...ation of switch System contact Note network contact IP address IP of this Hyperion NetMask Sub net mask Default Gateway DNS 1 DNS 2 Configure IP of DNS server to be used Security settings change user password Change Password The change password feature is under the Settings page as shown in screen below To change the password 1 Enter the new password cannot be blank 2 Click Update Security Setting...

Page 11: ...d of o etherCON ports o opticalCON Duo port model dependent o SFP port o LC Duplex ports Speed settings of ports can be specified Flow control disabled by default Supports flow control when enabled MTU specify the largest network layer protocol data unit Redundancy disabled by default Can only be set when the port is not in use ...

Page 12: ...s are allowed Simply drag the ports from Unlinked column to a Trunk Devices connected to Trunked ports must support 802 3af to work with Link aggregation Notes o Each trunk can have a maximum port 2 ports o First link the Ports in a Trunk and make the actual network connections afterwards o Link aggregation assumes that the connections are made on the same network device must support 802 3af o Red...

Page 13: ...ckup of the switch configurations Restore the switch Reboot the device Reset to factory defaults Restore to factory defaults web interface Resets password to default blank Resets username to admin Resets device IP to default of 192 168 0 10 Resets netmask to 255 255 255 0 Resets gateway to 0 0 0 0 Redundancy link on port 7 and 8 remains enabled after refresh of Home page ...

Page 14: ...ts device IP to default of 192 168 0 10 Resets netmask to 255 255 255 0 Resets gateway to 0 0 0 0 Redundancy link on port 7 and 8 are disabled Refresh web Home page once to enable Reboot Rebooting the device will restart your unit No settings will be affected Backup All user defined settings will be downloaded to a file config Note Renaming or changing the backup file will result in failure of sys...

Page 15: ...tec com hyperion Firmware update option is under the Administration Menu The steps for updating firmware are listed below 1 Select the firmware to be loaded to the device must be the correct firmware file for Hyperion only 2 Click on Update Firmware button WARNING Please do not interrupt or power off your Hyperion unit during a firmware update as this can crash your Hyperion unit Please be careful...

Page 16: ...ly 10 seconds It could take between 30 60 seconds for firmware update to complete It is important that you do not interrupt the firmware update procedure at any time Once restart is complete status LED should start blinking this shows it s ready In case a bad firmware update was attempted the following error screen will be shown If the page does not refresh please click the link at the bottom of t...

Page 17: ...shown in the image below Please wait for 60 seconds and refresh the page If it says Firmware update in progress please wait another 60 seconds and refresh If the page shows that Firmware update is complete as shown in the image below then please re power Hyperion Note Ensure Status indicator blinks green After re powering the unit web page should load normally Settings do not Save Please make sure...

Page 18: ...g settings of your computer as specified in settings for your computer Enter default IP of device 192 168 0 10 into an address bar of a browser of your choice If device web page is inaccessible reset device to factory settings by holding down reset button for ten seconds Wait one minute until status light of device is blinking green Re enter default IP of device 192 168 0 10 into an address bar of...

Page 19: ...gs for your Computer Steps for Windows 7 1 Click Start Control Panel Network and Internet Network and Sharing Center Change adapter settings 2 Select Internet Protocol Version 4 TCP IPv4 then click Properties Select Internet Protocol Version 4 TCP IPv4 Internet Protocol Version 4 Setting to be used ...

Page 20: ...n User Manual 51164 For latest version visit www enttec com January 19 ID 3809208 20 Steps for MacOS 1 Click System Preferences Network Ethernet 2 Select Configure IPv4 Manually and enter values as shown below ...

Page 21: ...ion SKU Model Handle Description 71025 HP1 82F Hyperion Gigabit Switch with OpticalCON Duo Front 71026 HP1 81 Hyperion Gigabit Switch NO OpticalCON 71027 HP1 82R Hyperion Gigabit Switch with OpticalCON Duo Rear 71028 HP1 83F Hyperion Gigabit Switch with LC Duplex Front 71029 HP1 83R Hyperion Gigabit Switch with LC Duplex Rear ...

Page 22: ...19 ID 3809208 22 Accessories and Recommended Products SKU Description 51155 Gigabit LC Fibre Optic Hyperion SFP Module SFP 1GE LX 1310nm 73910 US Mains plug powerCON cable 73911 UK Mains plug powerCON cable 73912 EU Mains plug powerCON cable 73913 AU Mains plug powerCON cable ...