INSTRUCTIONS FOR USE OF EOD MEDI EORG™ 
GENERATOR

 

 

Overview

 

 
Congratulations on acquiring your new EORG™ (Electronic Oxygen Radical Generator).

 

 
The user manual is part of your purchase and is only applicable to EOD MEDI device. 
Within this document are important instructions for safety, use of equipment and end of life 
disposal. Before using the product for the first time, please fully and carefully read this user 
manual. Use of the product in ways other than stipulated here may void your warranty. 
Store this document in a safe place, should you need to refer to it later.

 

 

Appropriate use

 

 
This device is intended for water enrichment with Reactive Oxygen Species (ROS). The 
device use with water use only! Do not use with any liquids or additives! Trace amounts of 
gaseous Oxygen radicals may be released into the area when the machine is in operation. 
While these are not harmful, it is recommended for the machine to be used in a well-
ventilated area. EOD Europe accepts no liability of any damage to materials or persons due 
to improper use of the equipment.

 

 
Continuous product development and improvement is at the heart of EOD Europe’s ethos 
and it is important you ensure the user manual revision is relevant to the device you are 
using.

 

 

Contents of your order:

 

 
1-

of EOD MEDI EORG™ Gen a power cord

 

1-of Power supply

 

1-of in-line dip switch

 

1-of power cord whit plug

 

1-of user manual (this document)

 

 

Technical information:

 

 

Power Supply p/n   

VY-12010000

 

Rated Voltage (input) 

100-240 V AC 50/60 Hz

 

Rated Current (input) 

2.5 A

 

Rated Voltage (output) 

12 V DC

 

Rated Current (output) 

10 A

 

Safety Protection 

 

class I

 

Dimensions   

 

about 15,5 cm (W) x diameter 8 cm

 

Weight 

 

 

660 g

 

Power cord length   

about 400 cm

 

Submerged power cord 

about 170 cm

 

EOD Europe reserves all rights to technical modifications, improvements, and document 
revisions.

 

Summary of Contents for MEDI EORG

Page 1: ...area when the machine is in operation While these are not harmful it is recommended for the machine to be used in a well ventilated area EOD Europe accepts no liability of any damage to materials or persons due to improper use of the equipment Continuous product development and improvement is at the heart of EOD Europe s ethos and it is important you ensure the user manual revision is relevant to ...

Page 2: ...t may pose a risk to domestic and commercial animals In addition animals may damage the device Care must be taken to keep the device and associated cabling away from animals DANGER of electrocution Do not touch EORG unit when switched on DANGER of electrocution The current transformer or switch must not come into contact with water or other liquids Do not use the device if there is visible damage ...

Page 3: ... contagious diseases Never attempt to use the device on sea water or anything other than water DANGER of water quality standards and recommendations for drinking water Please note that when using non resident safe water as domestic water different chemical quality standards and recommendations have been set for domestic water which may not be exceeded when water is used for household use DANGER of...

Page 4: ...he electrodes to be dissolved Turn off the EOD MEDI device give it a swirl in the container and then remove it from the water Dispose of the water treated after the first run with the machine Residual protective coating might be present in the water After this your EOD MEDI unit will be ready for use Ozonation of water container volume of five liter is assumed and times vary depending on the size ...

Page 5: ...switched on whilst submerged in clear water Stream s of micro bubbles will start to rise from the electrolysis plates The water is quickly filled with micro bubbles When the device is turned off the micro bubbles immediately begin to dissolve into the water The water is ready for disinfection once most of the micro bubbles have dissolved i e the water resumes a clear appearance Examples and notes ...

Page 6: ...mended to have the device fully disconnected from the electrical supply as running the device in the mixture is strictly prohibited 3 Rinse the device thoroughly with tap water and resume normal operation After the decalcify procedure normal micro bubble formation should resume If it does not the device might be worn out Life of the device The service life of the EOD MEDI generator is approximatel...

Page 7: ...us considered to be consumable parts The warranty is invalidated if the product is damaged used or maintained inappropriately The proper use of the product requires all the instructions contained in the instructions to be followed Use for purposes not complying with the instructions and not complying with warnings strictly prohibited Incorrect or inappropriate use use of force repairs made by non ...

Page 8: ...8 Contact Charlot OÜ Helgi tee 1 Peetri küla 75312 Harjumaa Eesti e mail eod charlot ee https eod charlot ee EOD EUROPE APPRECIATES YOUR CUSTOM Rev 2 1 2 15 03 2021 ...

Reviews: