background image

Model:

 

ELPMBP03

3215 W. North Ave.  •  Melrose Park, IL 60160  •  (800) 865-2112 or (708) 865-8870  •  Fax: (708) 865-2941  •  www.peerlessmounts.com

Maximum UL Load Capacity:

 150 lb (68 kg)

This product is UL Listed. It must be
installed by a qualified professional
installer.

R

Installation and Assembly:

Structural Round Ceiling Plate

Manufactured by Peerless Industries, Inc.

ISSUED: 02-13-08  SHEET #: 054-9126-2 07-10-08

Summary of Contents for ELPMBP03 - Structural Round Ceiling Plate

Page 1: ...65 2941 www peerlessmounts com Maximum UL Load Capacity 150 lb 68 kg This product is UL Listed It must be installed by a qualified professional installer R Installation and Assembly Structural Round Ceiling Plate Manufactured by Peerless Industries Inc ISSUED 02 13 08 SHEET 054 9126 2 07 10 08 ...

Page 2: ...ll safely support the combined load of the equipment and all attached hard ware and components Never exceed the Maximum UL Load Capacity If mounting to wood joists or wood beam ceilings make sure that mounting screws are anchored into the center of the joists or beams Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and...

Page 3: ...ppear slightly different than illustrated Before you begin make sure all parts shown are included with your product A B C D E F G Description Qty Part A round ceiling plate 1 055 2798 B 14 x 2 5 wood screw 4 5S1 015 C04 C M5 x 8 x 10 mm phillips screw 1 520 2005 D M5 x 8 x 10 mm socket pin screw 1 520 2031 E 4 mm allen wrench 1 560 9646 F rubber grommet 1 530 9401 G concrete anchor 4 590 0097 Part...

Page 4: ... grommet F into hole of ceiling plate A NOTE Make sure grommet overlaps retaining collar Grommet may require some force to fit in hole and will appear slightly deformed F A RETAINING COLLAR 1 Screw flush mount from top of ceiling plate A as shown in fig 2 Tighten four or five complete turns Align slot in flush mount tube with one of the small holes in the side of the threaded fitting Insert and ti...

Page 5: ...he equipment and all attached hardware and components Tighten wood screws so that ceiling plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess of 80 in lb 9 N M Make sure that mounting screws are anchored into the center of the wood joist or wood beam The use of an edge to edge stud finder is highly recomm...

Page 6: ...al If mounting to concrete surfaces covered with a finishing surface is unavoidable the finishing surface must be counterbored as shown below Be sure concrete anchors do not pull away from concrete when tightening screws If plaster drywall is thicker than 5 8 custom fasteners must be supplied by installer Not evaluated by UL WARNING Tighten screws so that ceiling plate is firmly attached but do no...

Page 7: ...LV QRW DXWKRUL HG IRU VXFK VHUYLFH RU UHSDLUV E 3HHUOHVV QGXVWULHV QF E WKH IDLOXUH WR XWLOL H SURSHU SDFNLQJ ZKHQ UHWXUQLQJ WKH SURGXFW F LQFRUUHFW LQVWDOODWLRQ RU WKH IDLOXUH WR IROORZ 3HHUOHVVҋ LQVWUXFWLRQV RU ZDUQLQJV ZKHQ LQVWDOOLQJ XVLQJ RU VWRULQJ WKH SURGXFW RU G PLVXVH RU DFFLGHQW LQ WUDQVLW RU RWKHUZLVH LQFOXGLQJ LQ FDVHV RI WKLUG SDUW DFWLRQV DQG IRUFH PDMHXUH Q QR HYHQW VKDOO 3HHUOHVV ...