Summary of Contents for ERB30Y

Page 1: ...6kg SDS Plus Rotary Hammer Drill ERB30Y WARRANTY YEARS ...

Page 2: ...use Lack of routine maintenance Failure of consumable items such as batteries Accidental damage Cosmetic damage Failure to follow manufacturer s guidelines Loss of use of the goods Repairs attempted by anyone unless authorised by Screwfix Direct Ltd Thisguaranteedoesnotaffectyourstatutoryrights ThisguaranteeisonlyvalidintheUK For further technical advice and spare parts please contact the customer ...

Page 3: ...k of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock f Use a...

Page 4: ... be repaired c Disconnect the plug from the power source before making any adjustments changingaccessories orstoringpowertools Suchpreventive safety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in...

Page 5: ...eep exposure to vibrations as short as possible 16 When carrying out work always hold the drill with both hands and ensure that you have a stable standing position 17 Lubricating the gear box The gear box must be lubricated after approximately 5 hours of use to ensure it works efficiently A small container of grease is supplied with the drill Go to section Maintenance for the details 18 Always use ...

Page 6: ...le insulation The tool is double insulated This means that all the external metal parts are electrically insulated from the mains power supply This is done by placing insulation barriers between the electrical and mechanical components making it unnecessary for the tool to be earthed ...

Page 7: ...6kg SDS Plus Rotary Hammer Drill 1 ON OFF SWITCH 2 FUNCTION SELECTOR 3 MODE SELECTOR 4 AUXILIARY HANDLE 5 FASTENING SLEEVE 6 MAINS POWER CABLE 7 SPANNER 8 SDS DRILL BITS 8 10 12MM 9 GREASE POT ...

Page 8: ...BRATION DATA Sound pressure level 85dB A Sound power level 96dB A Vibration level 5 2m s2 10 13MM KEY CHUCK AND ADAPTER 11 250MM SDS CHISEL BIT 20MM FLAT HEAD POINTED HEAD 12 DEPTH GAUGE 13 CHUCK KEY 14 DUST COVER ACCESSORIES Spanner 1pc SDS drill bits 3pcs Gease pot 1pc 13mm key Chuck and adapter 1pc SDS Chisel bit 2pcs Depth gauge 1pc Chuck key 1pc Dust cover 1pc ...

Page 9: ... sure the rotary hammer is isolated from the mains supply before fitting accessories Before undertaking any maintenance or operations on the rotary hammer isolate the plug from the 13 amp socket 1 FITTING THE AUXILIARY HANDLE Attach the handle as shown in Fig 2 depending on being left handed or right handed 2 FITTING SDS TOOLS OR CHUCK The rotary hammer is equipped with an SDS plus attachment syste...

Page 10: ... supply Place chuck key into chuck turn key anti clockwise to undo loosen chuck insert drill tool and firmly tighten chuck by turning key clockwise Remove key and replace in Blow Mould Case WARNING If the hammer drill selector can not go into position turn the gearbox Before operating select the required mode by aligning the symbol on the housing with the arrow on the function selecter The mode sel...

Page 11: ...t depth gauge into the handle see Fig 12 2 Adjust the depth gauge to desired depth 3 Rotate the screw to fix the depth gauge 10 SAFETY WHEN USING THE ROTARY HAMMER This is a powerful tool Caution needs to be observed when operating Dress in suitable overalls Safety boots are recommended at all times especially when using the chisel actions Proper safety gloves are also recommended When using chisel...

Page 12: ...ere are no user serviceable parts in your power tool 3 Never use water or chemical cleaners to clean your power tool Wipe clean with a dry cloth 4 Always store your power tool in a dry place 5 Keep the motor ventilation slots clean 6 If you see some sparks flashing in the ventilation slots this is normal and will not damage your power tool HANDY HINTS Always use sharp good quality drill bits and ch...

Page 13: ...s exist Check with your Local Authority or retailer for recycling advice PLUG REPLACEMENT The fuse in the main plug of your power tool should always be replaced with one of identical rating Check the voltage given on your power tool matches the supply voltage The power tool is supplied with a fitted plug however if you should need to fit a new plug follows the instruction below IMPORTANT The wire in...

Page 14: ...13 AMP FUSE BROWN L LIVE BLUE N NEUTRAL OUTER SLEEVE CABLE GRIP ...

Page 15: ...safety requirements of the following directives 89 336 EEC 93 68 EEC EMC Directive 73 23 EEC 93 68 EEC Low Voltage Directive 98 37 EC Machinery Directive Standards and technical specifications referred to EN 60745 1 2003 A1 2003 EN 60745 2 6 2003 EN 55014 1 2000 A1 2001 A2 2002 EN 55014 2 1997 A1 2001 EN 61000 3 2 2000 EN 61000 3 3 1995 A1 2001 2005 Authorised Signatory Date 03 15 05 Signature Name...

Page 16: ......

Reviews: