background image

 

 

 
 

 

 

Operating instruction 

Hydraulic system with Motor drive PXD compact

 

 

 

Document no.: B-00021 

Edition 2019 09

 

Operating instruction EN 

Copyright by Ergoswiss AG

 

1/25 

 

 

Operating instruction - Motor drive PXD compact 

to control and drive hydraulic lifting systems made by Ergoswiss AG 

 

 

 

 

It is essential to read this operating instruction thoroughly before commissioning the system. 

This operating instruction has to be stored in the immediate vicinity of the system.  

 

 

 

 

 Power cable 

 Control box compact-3-eco 

 Manual control switch Memory 

 Motor cable PXD  

 Motor PXD with front plate and housing PXD 

 Cable strain relief 

 PXD coupling for connection to the Ergoswiss  

     hydraulic pumps type PA, PB and PF (with Woodruff key) 

 
 
 
 
 

 

Errors and technical changes reserved.  
Ergoswiss AG does not assume any liability for operating 

errors or using the products outside of the intended 
purpose use. 
At the time of delivery Ergoswiss AG will replace or re-

pair defect products within accordance with the warran-
ty provisions. In addition, Ergoswiss assumes no other 
liability. 
For your questions and special custom demand          
Ergoswiss AG will be at your disposal. 

 

 

 

Ergoswiss AG 

Nöllenstrasse 15 
CH-9443 Widnau 
Tel.: +41 (0) 71 727 06 70 
Fax: +41 (0) 71 727 06 79 
 
info@ergoswiss.com 
www.ergoswiss.com 

 

 

 

 

 

 

 

 

Summary of Contents for 112.00081

Page 1: ...able PXD Motor PXD with front plate and housing PXD Cable strain relief PXD coupling for connection to the Ergoswiss hydraulic pumps type PA PB and PF with Woodruff key Errors and technical changes re...

Page 2: ...drive PAD 230 compact EU 112 00081 230 compact CH 112 00083 230 compact UK 112 00085 110 compact US 112 00087 230 compact IT 112 00089 Motor drive PBD 230 compact EU 112 00082 230 compact CH 112 0008...

Page 3: ...itch Memory 15 4 2 Initial operation with manual control switch Up Down 15 5 Operation 16 5 1 Drive Up Down 16 5 2 Duty cycle monitoring 16 5 3 Saving a memory position Only with manual control switch...

Page 4: ...ividually 1 2 Intended purpose use The motor drive PXD compact is exclusively intended to control and drive Ergoswiss AG hydraulic lifting sys tems While mounting the lifting system into a greater sys...

Page 5: ...2 Control box PXD compact 3 eco Supply voltage EU 207 254 4 V 50 Hz US 90 127 V 50 60 Hz Primary standby power 0 6 W Performance rate 83 300 W input power Hall sensor supply voltage 5 VDC 10 250 mA A...

Page 6: ...immediate threatening danger Non compliance with this information can result in death or serious personal injuries invalid ity WARNING Indicates a possible dangerous situation Non compliance with this...

Page 7: ...d in a potentially explosive atmosphere The control box must be protected from moisture dripping water as well as spray water The control box is not suitable for continuous use The operation hold rati...

Page 8: ...sible residual dangers for example by constructive measures or by instructions in the operating instructions and or by safety instructions on the system 3 1 Mounting and wiring of the motor 1 Connect...

Page 9: ...he cylinder of the motor 3 2 Mounting and wiring of the control box Mounting of the control box underneath a table top ATTENTION During mounting of the control box the power cable must be disconnected...

Page 10: ...made products to the control box is prohibited Only use supplied components 1 Connect the motor cable to the control box The continuous cable must be plugged into the motor socket M1 the split cable m...

Page 11: ...nnected to the correct sockets M1 M2 Is the entire lifting system assembled according to the assembly instructions NOTE The motor cable connecting the control box to the motor has a length of 950 mm I...

Page 12: ...control panel must overhang below the work surface 2 Fasten the mounting plate using the mounting screws Be careful not to drill through the table top 3 Slide the manual control switch onto the mounti...

Page 13: ...eath the table top The control panel must overhang below the work surface 2 Fasten the manual control switch using the mounting screws Be careful not to drill through the table top 3 3 4 Manual contro...

Page 14: ...an gers for example by constructive measures or by instructions in the operating instructions and or by safety instructions on the system ATTENTION While using the height adjustment of the work surfac...

Page 15: ...display in cm US 110 V version in inch 6 To confirm press S Save After confirmation the height is displayed no more flashing and the initial operation is completed NOTE The control box automatically o...

Page 16: ...an be operated again 5 3 Saving a memory position Only with manual control switch type Memory With this function it is possible to memorise a certain position height and approach it at a later time by...

Page 17: ...While doing so the system does not move 4 With the correctly set value the new height is saved by pressing S Save 5 6 Reset of the control box Only with manual control switch type Memory 5 6 1 Redefin...

Page 18: ...an be connected and synchronised The length of the SYNC 2 cable is 550 mm The SYNC cable cannot be extended If necessary the motor cables can be extended NOTE Always do reset before disconnecting Disc...

Page 19: ...SYNC cables are connected afterwards they will not be recognised by the control box and only one drive will move which can lead to jamming of the entire system NOTE When disconnecting the SYNC cable...

Page 20: ...rn Depending on the combination of systems hydraulic transmission ratio the system stops its movement 3mm 5mm or 10 5mm before the defined end position The safety strip compact 124 00105 consists of 7...

Page 21: ...strip both can also be connected with the split cable Gluing the contact tube in the squeeze zone Connecting the safety strip 1 Clean and degrease the contact face 2 Pull off a liner of acrylic foam o...

Page 22: ...ly original replacement parts may be used For all repair work the system must always be unloaded and voltage free ATTENTION In no case may the control box be opened There is the risk of an electrical...

Page 23: ...nt motor group 1 49 Excess current motor group 2 60 Collision protection 62 Excess current at the control 36 Plug detection at motor socket M1 Plug in the motor cable correctly at the respective socke...

Page 24: ...ed There is an error code to be checked on the display 3x 6x Last shut down incomplete forced reset There is an error code to be checked on the display 8 7 Trouble shooting Error Cause Rectification D...

Page 25: ...Operating instruction Hydraulic system with Motor drive PXD compact Document no B 00021 Edition 2019 09 Operating instruction EN Copyright by Ergoswiss AG 25 25 9 Declaration of Incorporation...

Reviews: