VIVO-M101(M)

Quick installation and programming guide

English

IMPORTANT 

NOTE

This quick guide summarises the full installation manual. The full manual contains safety warnings and other
explanations that must be taken into account. You can download the latest version of this guide and the
installation manual in the "Downloads" section of the Erreka website: 

http://www.erreka-automation.com

The options and functions described in this guide are applicable from the 

firmware

 version indicated on the

circuit. As part of a process of continuous improvement, the 

firmware

 is subject to the incorporation of new

functionalities or their extension, and consequently to the generation of new versions not necessarily
compatible with the previous ones. Therefore, if your 

firmware

 version is lower than the one indicated in

this guide, some options and functions may not be available or may be different.

E175A

ELECTRICAL CABLING:

Element

Nº wires x section

Maximum length

A: Main power supply

3x1.5mm

2

30m

B: Flashing light

2x0.5mm

2

20m

C: Photocells (Tx / Rx)

2x0.5mm

2

 / 4x0.5mm

2

30m

D: Pushbutton/wall key

2x0.5mm

2

25m

E: Operator / Limit switches

4x0.75mm

/ 4x0.50mm

2

20m

F: Antenna

Coaxial cable 50

k

 (RG-58/U)

5m

Elements of the complete installation

MS

A-097/03

firmware V2.00 or

 later

Summary of Contents for VIVO-M101

Page 1: ... continuous improvement the firmware is subject to the incorporation of new functionalities or their extension and consequently to the generation of new versions not necessarily compatible with the previous ones Therefore if your firmware version is lower than the one indicated in this guide some options and functions may not be available or may be different E175A ELECTRICAL CABLING Element Nº wir...

Page 2: ... or partially open DL1 DL3 flashing STOP contact open emergency stop activated DL2 Receiving RSD plug in receiver radio signal RUN OK DL3 Radio code or operation programming DL4 Opening relay activated DL5 Closing relay activated DL6 Interior safety device contacts FT2 closed DL7 FCA contacts closed DL8 FCC contacts closed DL9 Exterior safety device contacts FT1 closed DL10 Pedestrian key command ...

Page 3: ...DL2 flashes to show programming is complete 5 Place DIP1 and DIP4 in OFF DL3 remains off 6 Disconnect and reconnect the electrical power supply Programming is carried out in the same way using DIP6 instead of DIP4 R175B R175K Pedestrian opening radio code Total open close programming 1 Connect the electrical power supply and close the leaf keeping PUL1 pressed down 2 Place DIP1 in ON DIP2 in ON DI...

Page 4: ... obstacle detection the obstacles are only detected when the gate has come to a complete halt ON Function activated during quick travel the gate detects obstacles upon collision and recedes when soft stop is activated DIP8 ON or remains shut down when soft stop is disabled DIP8 OFF in order to prevent crushing OFF Function disabled DIP10 Dead man function Only with DIP4 OFF and DIP11 OFF ON Dead m...

Reviews: